Geri Dön

Farklı yüzey özelliklerine sahip dental implant drillerinin kemikte oluşturdukları ısınma etkilerinin değerlendirilmesi

Evaluation of heat production in bone caused by dental implant drills with different surface characteristics

  1. Tez No: 331381
  2. Yazar: NİLAY ER
  3. Danışmanlar: PROF. DR. ALPER ALKAN
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Dental implant, dril, ısı nekrozu, yüzey kaplama, Dental implantasyon, Dental implantlar, Kemik ve kemikler, Nekroz, Yüzey özellikleri, dental implant, drill, heat necrosis, surface coating, Dental implantation, Dental implants, Bone and bones, Necrosis, Surface properties
  7. Yıl: 2012
  8. Dil: Türkçe
  9. Üniversite: Erciyes Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, dental implant drillerini sert ve dayanıklı malzemeler ile kaplayarak kemikte daha az ısınma oluşturan, kullanım ömrü uzun ve aşınmaya dirençli drillerin elde edilip edilemeyeceğini ortaya çıkarmaktır. Çalışmada farklı yüzey özelliklerine sahip toplam 7 (yedi) drill grubu incelenmiştir. Bu gruplar; Paslanmaz Çelik (PÇ), Siyah Elmas (SE), Zirkonyum (ZR), Titanyum Alüminyum Nitrür (TiAlN), Bor Nitrür (BN), Titanyum Bor Nitrür (TiBN) ve Elmas Benzeri Karbon (EBK)' dur. Çalışmaya dahil edilen paslanmaz çelik, siyah elmas ve zirkonyum işlemeli olan üç grup piyasada hali hazırda bulunurken, titanyum alüminyum nitrür, bor nitrür, titanyum bor nitrür ve elmas benzeri karbon grupları, paslanmaz çelik drillerin üzerine fiziksel buhar biriktirme yöntemi ile yüzeyleri kaplanarak elde edilmiştir. Her bir grup 20 drilden oluşmaktadır. Bu drillerden 10 tanesi klinik uygulamada yapıldığı gibi serum fizyolojik ile su soğutması altında, diğer 10 tanesi ise herhangi bir soğutma sistemi olmadan kemikte oluşturdukları ısı ölçülmüştür. Drillerin kemikte oluşturdukları ısıyı değerlendirmek üzere cerrahi tur motoru, paralelometre cihazına adapte edilerek taze sığır femuru kortikal kemiğinde 1 dakika boyunca drilleme işlemi yapılmıştır. Drilleme boyunca oluşan sıcaklık, dril yuvasının 1 mm yanında, 4 mm ve 8 mm derinliğinde 2 adet ısı sensörü yerleştirilerek ölçülmüştür. Her dril için bu işlem 50 kere tekrarlanmış ve 1., 25. ve 50. drillemelerde yapılan ısı ölçümleri kaydedilmiştir. Sonuç olarak en az sıcaklık artışı gözlenen grup Bor Nitrür grubu olmuştur. Su soğutması olmadan yapılan 50. drilleme ısı ölçümünde bile kemik nekrozu için kritik değer olan 47 ?C yi geçecek sıcaklık artışı oluşmamıştır. Piyasada mevcut olan siyah elmas ve zirkonyum grupları ise ısı artışının en çok olduğu gruplar olarak saptanmıştır.

Özet (Çeviri)

The purpose of this study is to investigate whether wear-resistant and durable drills with protective coatings can be produced or not. Seven groups with different surface characteristics were examined. The examined surface coatings were; Stainless Steel, Black Diamond, Zirconium, Titanium Aluminum Nitride, Boron Nitride, Titanium Boron Nitride and Diamond Like Carbon. While stainless steel, black-diamond and zirconium are commercially available, remaining four groups of titanium aluminum nitride, titanium boron nitride, boron nitride and diamond-like carbon were newly developed by surface coating onto stainless steel drills with physical vapor deposition method. Each group consisted of twenty drills. In each group ten drills were examined under water cooling with saline to mimic clinical practice. The other ten drills were examined without any cooling system. A surgical motor system was adapted to a parallelometer to measure the heat produced by the drills. Fresh bovine femur cortical bone was used to perform the drilling for one minute. The heat was measured by two thermocouples which were placed 1 mm away from the drilling slot in 4 mm and 8 mm depths simultaneously. Drilling was repeated 50 times for each drill, and the 1st, 25th and 50th drilling measurements were recorded. As a result, Boron-contained surface coatings showed a remarkably higher performance. Even after 50 usages in uncooled conditions, maximum temparature was below the critical value of 47 ?C for bone necrosis in Boron Nitride group. While diamond-like carbon showed higher performance than stainless steel, titanium aluminum nitride groups showed similar results. The black diamond and zirconium were the groups in which the most increase in temparature was observed.

Benzer Tezler

  1. İyileşme döneminde uygulanan LED fotobiyomodülasyon tedavisinin farklı yüzey özelliklerine sahip dental implantlarda, implant stabilite oranlarına etkisinin rezonans frekans analizi ile karşılaştırmalı olarak incelenmesi

    A comparative examination of the effects of the LED photomodulation therapy on stabilities of dental implants with different surface properties as assessed by resonance frequency analysis

    ÖZDE SEZGİN ÇİNKILIÇ

    Doktora

    Türkçe

    Türkçe

    2011

    Diş HekimliğiHacettepe Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. CELAL BAHADIR GİRAY

  2. Farklı yüzey özelliklerine ve geometrik tasarımlara sahip implantlarda marjinal kemik kaybının incelenmesi: retrospektif bir klinik çalışma

    Investigation of marginal bone loss in implants with different surface properties and geometric designs: A retrospective clinical study

    MERT KARABAĞ

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2023

    Diş HekimliğiRecep Tayyip Erdoğan Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    DOÇ. ZEYNEP GÜMRÜKÇÜ

  3. Farklı yüzey özelliklerine sahip implantlarda Basıc Fıbroblast Growth Factor'ün implant çevresindeki sert doku iyileşmesine etkisinin mekanik testler ile değerlendirilmesi

    Evaluation of the impact of basic fibroblast growth factor on periimplant hard tissue regeneration in implants with varying surface characteristics by mechanic tests

    YASEMİN KARTAL

    Doktora

    Türkçe

    Türkçe

    2009

    Diş HekimliğiAnkara Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. CAHİT ÜÇOK

  4. Düşük düzey lazer terapinin farklı yüzey özelliklerine sahip dental implantlara etkisinin, biyomekanik ve immünohistokimyasal açıdan tavşan modelinde incelenmesi

    Study of the effects of low frequency laser therapy over dental implants with different surficial properties biomechanically and immunohistochemically with rabbit modelling

    SELİN SAYGINSOY ADIGÜZEL

    Doktora

    Türkçe

    Türkçe

    2018

    Diş Hekimliğiİstanbul Üniversitesi

    Ağız, Diş ve Çene Cerrahisi Ana Bilim Dalı

    PROF. DR. HAKKI TANYERİ

  5. Farklı dental implant yüzey özelliklerinin kemik immünolojik biyomarkırları ve mikrobiyolojik parametreler üzerine etkisi: Randomize klinik çalışma

    Impact of different dental implant surfaces on osteoimmunological biomarkers and microbiological parameters: A randomized clinical trial

    BİLGE KARCI

    Diş Hekimliği Uzmanlık

    Türkçe

    Türkçe

    2017

    Diş HekimliğiNecmettin Erbakan Üniversitesi

    Periodontoloji Ana Bilim Dalı

    YRD. DOÇ. DR. ELİF ÖNCÜ