Gövde uzunluğunun zirkonya alt yapılı sabit parsiyel protezlerin klinik başarısına etkisi
The effect of span length on clinical performance of y-tzp fixed partial dentures
- Tez No: 329129
- Danışmanlar: PROF. DR. DENİZ GEMALMAZ
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental porselen, Takma diş tabanları, Takma diş-kısmi, Takma dişler, Zirkonyum, Dental porcelain, Denture bases, Denture-partial, Dentures, Zirconium
- Yıl: 2012
- Dil: Türkçe
- Üniversite: Marmara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Diş Hekimliği Bölümü
- Bilim Dalı: Protetik Diş Tedavisi Ana Bilim Dalı
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmanın amacı, gövde uzunluğunun yttria ile güçlendirilmiş zirkonya alt yapılı sabit parsiyel protezlerin klinik başarısına ve marjinal adaptasyonuna etkisinin değerlendirilmesidir. CAD/CAM sistemi ile üretilen (LAVA, 3M ESPE) 34 adet sabit parsiyel protez 25 hastaya uygulandı. Sabit parsiyel protezler gövde uzunluğuna göre; (1) 3 üye ve (2) 4 üye restorasyonlar olarak 2 gruba ayrıldı. Üst yapı porseleni olarak e-max Ceram (Ivoclar) kullanıldı. Restorasyonlar, simantasyonu takiben başlangıç, 6.ay, 12. ay, 18. ay, 24. ay, ve 30. ayda CDA kriterleri, plak ve gingival indeks ölçümleri ve hasta memnuniyeti değerlendirme kriterleri ile değerlendirildi. Marjinal ve internal adaptasyon ölçümleri ışık mikroskobu altında silikon replika tekniği ile yapıldı. İstatistiksel analiz için ?Kruskal Wallis? ve ?Wilcoxon Signed Ranks? testleri kullanıldı. Takip süresi boyunca alt yapı kırığına rastlanmadı. İki adet restorasyonda 3. ve 6. aylarda desimantasyon gözlendi. Ortalama marjinal aralık değerleri uzun gövde mesafesine sahip restorasyonlarda 70,92(±40,02) µm, kısa gövde mesafesine sahip restorasyonlarda 88,01(±54,34) µm olarak bulundu. En yüksek internal aralık değeri okluzal bölgede; en düşük internal aralık değeri ise marjinal bölgede gözlendi (P<0.05). Gövde uzunluğuna bağlı istatistiksel olarak anlamlı fark gözlenmedi. Tüm klinik değerlendirme kriterleri göz önüne alındığında ortalama 18 aylık değerlendirme periyodunda 34 adet zirkonya restorasyon için klinik olarak kabul edilebilir değerler kaydedilmiştir. Bu erken dönem sonuçlara dayanarak, zirkonya alt yapılı sabit parsiyel protezlerin uzun gövde mesafesi olan posterior bölge restorasyonlarında ümit verici olduğu söylenebilir.
Özet (Çeviri)
The Effect Of Span Length On Clinical Performance Of Y-TZP Fixed Partial DenturesThe aim of this study was to evaluate the effect of span length on clinical performance and adaptation of Y-TZP fixed partial dentures. Thirty four zirconia FPDs using a CAD/CAM system (LAVA, 3M Espe) were placed to 25 patients. FPDs were divided into two groups; (1) 3 units and (2) 4 units. Frameworks were layered with e-max Ceram (Ivoclar). A self adhesive luting cement, G-Cem Automix (GC) was used. Restorations were clinically assessed at baseline, 6, 12, 18, 24, 30 months after cementation by using `California Dental Association Criteria?, plaque and gingival indexes and patients satisfaction criteria. The marginal and internal adaptation was measured under an optical microscope using silicone replica technique. ?Kruskal Wallis? and ?Wilcoxon Signed Ranks? tests were used for statistical analysis (P<0.05). No framework fracture was observed. One restoration showed veneer porcelain chipping after 6 months; 2 restorations were debonded at 3rd and 6th months, respectively. The mean marginal gaps were 70,92(±40,02) µm for extended span length Y-TZP FPDs and 88,01(±54,34) µm for short span length Y-TZP FPDs. The highest gap value was observed at the occlusal area and lowest one at the marginal area.(P<0,05) There was no significant difference in relation to span length.Regarding all of the clinical evaluation criteria all 34 zirconia FPDs exhibited clinically acceptable scores within an average evaluation time of 18 months. Relying on these early results, zirconia fixed partial dentures even with long span lengths seems to be promising in the posterior area.
Benzer Tezler
- CAD-CAM materyalleri ile üretilen implant üstü restorasyonların farklı siman aralıklarındaki stres dağılımlarının karşılaştırılması
Comparison of stress distributions in different cement thicknesses of implant- retained fixed restorations produced with current CAD-CAM materials
RAZİYE YILDIZ
Diş Hekimliği Uzmanlık
Türkçe
2021
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. AYŞE GÖZDE TÜRK
- Sarıcakya sokulum kayalarının (Eskişehir, KB Türkiye) petrojenezi ve önemleri
Petrogenesis of the Saricakaya intrusive rocks (Eskişehir, NW Turkey) and their implications
MALİK OTHMAN
Yüksek Lisans
Türkçe
2016
Jeoloji Mühendisliğiİstanbul Teknik Üniversitesiİklim ve Deniz Bilimleri Ana Bilim Dalı
PROF. DR. GÜLTEKİN TOPUZ
- Gövde boşluklu prefabrik betonarme aşıkların düşey yükler altında davranışı
Behavior of prefabricated reinforced concrete purlins having web openings under vertical loads
EMRULLAH ÇELEDİR
Yüksek Lisans
Türkçe
2022
İnşaat MühendisliğiKonya Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
PROF. DR. MUSA HAKAN ARSLAN
DR. ÖĞR. ÜYESİ CEYHUN AKSOYLU
- Gövde borulu ısı değiştiricilerinin bilgisayar destekli tasarımı
Computer aided design for shell and tube heat exchangers
ASIM BALBAY
Yüksek Lisans
Türkçe
2001
Makine MühendisliğiFırat ÜniversitesiMakine Eğitimi Ana Bilim Dalı
DOÇ.DR. YASİN VAROL
- Farklı boydaki implanlar arasında gövde uzunluğu artışının, gelen kuvvetler karşısındaki implant ve çevre kemik dokusunda oluşan stres dağılımının üç boyutlu sonlu elemanlar analizi yöntemiyle incelenmesi
Evaluation of stress distribution of the implant and surrounding bone against the forces on increased length of pontics supported by different length implants, using three-dimensional stress analysis
RÜYA GİZEM KOÇAK
Diş Hekimliği Uzmanlık
Türkçe
2020
Diş HekimliğiKaradeniz Teknik ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. SUBUTAY HAN ALTINTAŞ