Geri Dön

Yoğunluk ayarlı radyoterapi tekniği kullanılarak tedavi edilen baş-boyun kanserli hastaların tedavi planlarının dozimetrik olarak incelenmesi

Dosimetric investigation of treatment plans of head and neck cancer patients who were treated by using intensity modulated radiation therapy technique

  1. Tez No: 316762
  2. Yazar: ŞİLEM YÜCE
  3. Danışmanlar: PROF. DR. GÖKAY KAYNAK
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Oncology, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: YART, dozimetrik doğrulama, 2D Array, EPID, gamma indeksi, Dedektörler, Kafa ve boyun neoplazmları, Kalite güvence sistemi, Radyometri, Radyoterapi, Radyoterapi-bilgisayar yardımlı, İyon odası, IMRT, dosimetric verification, 2D Array, EPID, gamma index, Detectors, Head and neck neoplasms, Quality assurance system, Radiometry, Radiotherapy, Radiotherapy-computer assisted, Ionization chamber
  7. Yıl: 2012
  8. Dil: Türkçe
  9. Üniversite: Uludağ Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Radyasyon Onkolojisi Ana Bilim Dalı
  12. Bilim Dalı: Tıbbi Radyofizik Bilim Dalı
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZETBu çalışmada amaç, Yoğunluk Ayarlı Radyoterapi (YART) tekniği kullanılarak tedavi edilen baş-boyun kanserli hastaların doz dağılımlarının, farklı dozimetrik ekipmanlar kullanılarak doğrulanması ve bu ekipmanların uygulanabilirlik açısından birbirleriyle karşılaştırılmasıdır.Uludağ Üniversitesi Tıp Fakültesi Radyasyon Onkolojisi Anabilim Dalı'nda tedavi edilen 20 baş-boyun kanserli hastanın BT görüntüleri 3 mm kesit aralıkları ile taranmıştır. Taranan görüntüler konturlama bilgisayarına aktarılıp radyasyon onkoloğu tarafından hedef hacim ve riskli organlar konturlandıktan sonra üç boyutlu görüntüleri elde edilmiştir. Elde edilen görüntüler CMS XIO Tedavi Planlama Sistemi'ne (TPS) aktarılarak her hasta için hedef hacme ve bu hedefin sağlıklı organlarla komşuluğuna bağlı olarak YART planları tersten planlama (inverse planning) yöntemi kullanılarak oluşturulmuştur. 0.015 hacimli PinPoint (PTW, Freiburg, Germany) silindirik iyon odası ile merkezi doz doğrulaması yapılırken, PTW 2D ARRAY (seven29) ve Elektronik Portal Görüntüleme Cihazı (EPID) ile plan doğrulaması yapılmıştır. Gamma indeksi yönteminde doz farkı (DD) %3 ve doz mesafe uyumu (DTA) 3 mm kriterleri kabul edilmiştir.Pinpoint iyon odası ile merkezi doz doğrulamasında, TPS' den alınan doz değerleri ile ölçülen dozlar arasında en yüksek yüzde fark %3,07, en düşük yüzde fark %1,08, ortalama fark %2,29 ve standart sapma değeri 0.41 olarak bulunmuştur. TPS ile 2D Array karşılaştırmasında gamma indeks yöntemine göre %3 doz farkı (DD) ve 3 mm doz mesafe uyumu (DTA) kriterleri dikkate alınarak yapılan değerlendirmede geçen noktaların yüzdesi en yüksek %97,73 ve en düşük %88,55, ortalama değer %94,09 ve standart sapma değeri 2,27 olarak bulunmuştur. Elektronik Portal Görüntüleme Cihazı (EPID) ile elde edilen doz haritaları ile TPS karşılaştırmasında ise, yapılan değerlendirme sonucu geçen noktaların yüzdesi en yüksek %98,84 ve en düşük %91,59, ortalama değer %96,05 ve standart sapma değeri 1,63 olarak bulunmuştur.Sonuç olarak, YART planlarının doğrulaması için elde ettiğimiz sonuçların TPS ile uyumlu ve kabul sınırları içerisinde olduğu saptanmıştır. İki boyutlu iyon odası (2D ARRAY seven 29) ile EPID' in birbirlerine alternatif yöntemler olduğu görülmüştür. Ayrıca, YART doğrulaması için yapılan rutin uygulamalarda EPID sisteminin daha az zaman aldığı ve uygulanabilirlik açısından daha pratik olduğu tespit edilmiştir.

Özet (Çeviri)

SUMMARYThe purpose of this study is to verify the dose distributions of head and neck cancer patients treated with Intensity Modulated Radiation Therapy (IMRT) technique by using various dosimetric equipments and to compare these equipments in terms of their applicability.CT images of 20 patients who were treated in Uludag University School of Medicine Department of Radiation Oncology were scanned with 3 mm slice intervals. The scanned images were transferred to contouring computer and their three dimensional images were obtained after contouring the target volume and organs at risk. After transferring these images to the treatment planning system, IMRT plans were done for each patient by using inverse planning method depending on the target volume and neighborhood of target with healthy organs. The verification of central dose was done by using PinPoint (PTW, Freiburg, Germany) ionization chamber which have 0.015 volume and the plan verification was done by using PTW 2D ARRAY (seven29) and Electronic Portal Imaging Device (EPID). 3% dose difference and 3 mm distance to aggreement criteria were adopted while using Gamma index method.During the verification of central dose with Pinpoint ionization chamber, the difference between the values taken from TPS and measured dose values were highest 3,07%, lowest 1,08% and mean difference and standard deviation were found 2,29% and 0,41, respectively. While comparing TPS with 2D Array 3% dose difference and 3 mm distance to aggrement criteria were taken into consideration and the percentage of the points passed were found maximum 97,73%, minimum 88,55% and mean and standard deviation values were 94,09% and 2,27, respectively. While comparing the dose maps obtained with Electronic Portal Imaging Device (EPID), as a result of the evaluation the perccentage of points passed were found maximum 98,84%, minimum 91,59% and mean and standard deviation values were 96,05% and 1,63, respectively.Consequently, the results we obtained for the verification of IMRT plans were within the limits of acceptance and compatible with the TPS. It was seen that the two-dimensional ionization chamber (2D array, seven 29) and EPID were alternative methods to each other. InIXaddition, it was determined that EPID has taken less time and was more practical in terms of applicability during routine verification of IMRT plans.

Benzer Tezler

  1. Baş-boyun kanserlerinin tedavisinde yoğunluk ayarlı radyoterapi ve 3 boyutlu konformal radyoterapi tedavi planlarının karşılaştırılması

    A treatment planning comparison of 3 dimensional conformal radiotherapy and intensity modulated radiotherapy for treatment of head and neck tumours

    ZİYAFER GİZEM PORTAKAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2012

    Fizik ve Fizik MühendisliğiÇukurova Üniversitesi

    Fizik Ana Bilim Dalı

    PROF. DR. ZEHRA YEĞİNGİL

    PROF. DR. CANDAŞ TUNALI

  2. VMAT tekniği kullanılarak yapılan tedavi planlarının hastaya özel doğrulamasında farklı yöntemlerle elde edilen gamma indeks değerlerinin karşılaştırılması

    Comparison of gamma index values obtained by different methods in patient specific verification of treatment plans using VMAT technique

    MUSTAFA BUDAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2018

    OnkolojiAcıbadem Mehmet Ali Aydınlar Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. KAZIM MERİÇ ŞENGÖZ

  3. Baş-boyun kanserleri radyoterapisinde farkli planlama tekniklerinin tiroid bezi dozuna etkisi

    Effects of different radiotherapy planning techniques in head neck cancer to the thyroid gland doses

    GÖZDE SEÇİL KARA

    Yüksek Lisans

    Türkçe

    Türkçe

    2011

    OnkolojiDokuz Eylül Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    PROF. DR. FADİME AKMAN

    YRD. DOÇ. DR. KADİR AKGÜNGÖR

  4. Baş boyun bölgesi kanseri tanısı konmuş hastalarda yoğunluk ayarlı radyoterapinin doz dağılımının araştırılması

    Investigation dose distribution of intensity modulated radiotherapy on diagnosed head and neck cancer

    MURAT KÖRKÖSE

    Yüksek Lisans

    Türkçe

    Türkçe

    2013

    Fizik ve Fizik MühendisliğiÇukurova Üniversitesi

    Medikal Fizik Ana Bilim Dalı

    YRD. DOÇ. DR. H. SUAT ARSLANTAŞ

  5. Baş-boyun kanserlerinin radyoterapisinde farklı vmat tedavi plan tasarımlarının plan kalitesi açısından karşılaştırılması

    Comparison of different vmat treatment plan designs in radiotherapy of head and neck cancers in terms of plan quality

    EZGİ YILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2021

    Radyasyon OnkolojisiEge Üniversitesi

    Radyasyon Onkolojisi Ana Bilim Dalı

    PROF. DR. MUSTAFA ADNAN ESASSOLAK