Modified 3D sensitivity matrix method and use of multichannel current source for magnetic resonance electrical impedance tomography (MREIT)
Değiştirilmiş 3B hassasiyet matrisi metodu ve çok kanallı akım kaynağının manyetik rezonans elektriksel empedans tomografi (MREET) için kullanılması
- Tez No: 297745
- Danışmanlar: PROF. DR. YUSUF ZİYA İDER
- Tez Türü: Yüksek Lisans
- Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
- Anahtar Kelimeler: Manyetik rezonans tomografisi, Sonlu elemanlar, Tıbbi görüntüleme, Magnetic resonance tomography, Finite elements, Medical imaging
- Yıl: 2012
- Dil: İngilizce
- Üniversite: İhsan Doğramacı Bilkent Üniversitesi
- Enstitü: Mühendislik ve Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Elektrik ve Elektronik Mühendisliği Bölümü
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Manyetik Rezonans Elektriksel Empedans Tomografi (MREET) bir cism (örneğin insan vücudu) içerisindeki elektriksel iletkenlik dağılımını görüntülemek için kullanılan bir yöntemdir. Bu yöntem üç aşamadan oluşmaktadır: cisime akım uygulanması, manyetik akı yoğunluğunun Manyetik Rezonans Görüntüleme sistemi ile ölçülmesi ve ölçülen manyetik akı yoğunluğundan iletkenlik dağılımının oluşturulması. Her ne kadar, cisimin elektriksel iletkenlik dağılımını oluşturmak için başka algoritmalar olsa da bu tezde Hassasiyet Matrisi Metodu üç boyutlu (3B) problemler için incelenecektir. Hassasiyet Matrisi Metodu, MREET'de 3B problemler için yaygın olarak kullanılan bir yöntem değildir çünkü Hassasiyet Matrisi Metodu'nun üç boyutlu problemlerde uygulanması için gereken bilgisayar hafızası ve zaman oldukça fazladır. Hassasiyet matrisinin hesaplanması, bu yöntemin en çok zaman alan kısmıdır. Dolayısıyla bu tezde hassasiyet matrisinin hesaplanma süresini düşüren bir değişiklik önerilmiştir. Hassasiyet matrisi her yenileme basamağında hesaplandığı için, bu değişiklik algoritmayı önemli ölçüde hızlandıracaktır. Ayrıca iletkenlik dağılımı için varsayımlar yapılarak çözümü kolaylaştırmak mümkündür. Bu tezde cisimin içerisindeki iletkenlik dağılımının z den (z MRG sisteminin ana manyetik alan yönüdür) bağımsız olduğu kabul edilmiştir. Böylece hassasiyet matrisinin boyutu küçülmekte ve cisim içerindeki iletkenlik dağılımının hesaplanması için gereken süre önemli ölçüde azalmaktadır. Hassasiyet Matrisi Metodu'nun uygulanmasında karşılaşılan bir başka problem ise varsayılan ilk iletkenlik değeri için hesaplanan manyetik akı yoğunluğu, ölçülen manyetik akı yoğunluğundan çıkartıldığında, elde edilen manyetik akı yoğunlunda hataların olmasıdır. Bu hatalar simülasyonda kullanılan cisimle gerçekte kullanılan cismin kenar bilgilerinin örtüşmemesinden, simülasyonda yapılan hesaplardaki hatalardan ya da ölçümlerdeki yanlışlardan kaynaklanabilmektedir. Bu tezde, bu hataları azaltmak için çok kanallı akım kaynağının kullanılması önerilmiştir. Çok kanallı akım kaynağı bu hataları azaltmakla kalmayıp cisim içerisinde neredeyse homojen bir akım dağılımı sağlamaktadır.
Özet (Çeviri)
Magnetic Resonance Electrical Impedance Tomography (MREIT) is a technique to image the electrical conductivity distribution inside the object (such as a human body). This technique consists of three steps: current injection into the object, the measurement of the magnetic flux density by a Magnetic Resonance Imaging (MRI) system, and the reconstruction of the conductivity distribution from the measured magnetic flux density. Although there are other algorithms to reconstruct the conductivity distribution inside the object, in this thesis, the Sensitivity Matrix Method is investigated for 3D problems. In MREIT, the use of the Sensitivity Matrix Method is not common for 3D problems. This is because of the fact that for 3D problems the Sensitivity Matrix Method requires large memory space and long calculation time. Calculation of the sensitivity matrix is the most time consuming part of this method. Therefore in this thesis, a modification is proposed in order to reduce the calculation time of the sensitivity matrix. Since the sensitivity matrix will be calculated at each iteration, this modification speeds up the algorithm significantly. Also by making several assumptions regarding the conductivity distribution of the object, the problem may be further reduced. In this thesis, conductivity distribution inside the object is assumed to be z-invariant (z is the direction of the main magnetic field of the MRI system).Thus the dimension of the sensitivity matrix and the time required to calculate the conductivity distribution inside the object significantly decrease. Another problem with the application of the Sensitivity Matrix Method is that the magnetic flux density calculated by subtracting the calculated magnetic flux density (for the assumed initial conductivity distribution) from the measured one has errors. These erros are results of the boundary mismatches between the simulation object and the real object, inaccuracies in calculations and measurement artifacts. In this thesis, use of a multichannel current source is proposed in order to reduce these errors. Using the multichannel current source not only reduces the errors due to the boundary mismatches and other reasons but also sustains a nearly uniform current distribution inside the object.
Benzer Tezler
- Uyarlamalı süzgeçler
Adaptive filters
RIDVAN AYSEL
Yüksek Lisans
Türkçe
1994
Elektrik ve Elektronik Mühendisliğiİstanbul Teknik ÜniversitesiPROF.DR. AHMET H. KAYRAN
- Anahtarlamalı relüktans motorların matematik modelinin elde edilmesi ve simülasyonu
Başlık çevirisi yok
KEMAL ŞAHİN
Yüksek Lisans
Türkçe
1995
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve Kontrolİstanbul Teknik ÜniversitesiPROF.DR. M. KEMAL SARIOĞLU
- Mortalite oranlarındaki sapmalar ve karma sigortanın sapma ortamındaki istikrarı
Başlık çevirisi yok
ALİ CANYÜREK
Yüksek Lisans
Türkçe
1996
SigortacılıkMarmara ÜniversitesiSigortacılık Ana Bilim Dalı
YRD. DOÇ. DR. KAYLAV ŞEVKİ
- Savaş gemilerinde radar saçılma yüzeyi hesabı
Başlık çevirisi yok
SEVİLAY CAN
Yüksek Lisans
Türkçe
1999
Denizcilikİstanbul Teknik ÜniversitesiGemi İnşaatı ve Gemi Makineleri Mühendisliği Ana Bilim Dalı
PROF. DR. EŞREF ADALI
- Development of conductive polymeric materials for sensor applications
Sensör uygulamaları için iletken polimerik malzemelerin geliştirilmesi
DİDEM AYCAN
Doktora
İngilizce
2023
Polimer Bilim ve TeknolojisiMarmara ÜniversitesiKimya Mühendisliği Ana Bilim Dalı
DOÇ. DR. NESLİHAN ALEMDAR YAYLA
PROF. DR. FATMA KARACA ALBAYRAK