Geri Dön

Laboratuvar ölçekli güç sistem modelinin gerçek zamanlı tasarımı ve uygulaması

Real-time design and application of laboratory-scale power system model

  1. Tez No: 290904
  2. Yazar: HAKAN ÇANKAYA
  3. Danışmanlar: YRD. DOÇ. DR. AHMET YÖNETKEN, YRD. DOÇ. DR. MURAT CANER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Teknik Eğitim, Elektrik ve Elektronik Mühendisliği, Technical Education, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: Afyon Kocatepe Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik Eğitimi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu araştırmada, laboratuvar ölçekli güç sistem modelinin gerçek zamanlı kurulumu yapılmıştır. Kurulumu yapılan bu sistem bilgisayarla gerçek zamanlı denetlenen kapalı çevrim bir sistemdir. Bu güç sisteminde gözlenmek istenen değerlerimiz senkron generatör tarafından üretilen gerilim ve sistem devir sayısıdır. Sistemle bilgisayar arasındaki bağlantı PCI 1716 DAQ kartının bilgisayar donanımına bağlantısı yapılarak sağlanmıştır. MATLAB 10.0 versiyonu kullanılarak bir senkron generatörün devir ve yük çeşidine bağlı olarak gerilim denetimi yapılmıştır. MATLAB'de Real Time ve Simulink Toolbox kullanılarak bir kontrol modeli oluşturulmuştur. Bu kontrol modelinde program kütüphanesinde bulunan PID denetleyici kullanılmıştır. Gerilim ve devir referans değer ile karşılaştırılarak ortaya çıkan hata PID denetleyiciye uygulanmış ve sistem cevabı veri şeklinde elde edilmiştir. Bu veriler kullanılarak sistem cevap eğrileri MATLAB programında çizdirilmiştir.Sistemde bozucu etki olarak omik, endüktif ve kapasitif yükler kullanılmıştır. Sistem ilk olarak yüksüz (boşta) çalıştırılmıştır. İkincisinde sadece dirençlerden oluşan üç fazlı, yıldız bağlı yük devreye alınmıştır. Üçüncüsünde direnç ve bobinlerden oluşan üç fazlı, yıldız bağlı yük devreye alınmıştır. Dördüncüsünde direnç ve kondansatörlerden oluşan üç fazlı, yıldız bağlı yük devreye alınmıştır. Beşinci ve son çalışmada ise direnç, bobin ve kondansatörlerden oluşan üç fazlı, yıldız bağlı yük devreye alınmıştır.Bu çalışmalarda sistemin gerilim ve devir sayısı grafikleri incelenmiş ve sisteme uygulanan PID denetimle senkron generatörün gerilim ve devir değerinin referans değerine kısa bir sürede yerleştiği grafiklerden anlaşılmıştır.DC Motorun devir sayısının ayarlanması ve senkron generatörün uyartım akımı optik izoleli analog çıkış kartı tarafından sağlanmıştır. Bu kart denetim modelinin analog çıkışından gelen sinyallere göre DC motor sürücüsünün kontrol sinyalini ve senkron generatörün uyartımını ayarlar. Kartın özelliği deneysel sistemi kartlarımızdan izole etmesidir.

Özet (Çeviri)

In this research, laboratory-scale model of the power system has been the installation of real-time. Installation of this system is in real-time computer controlled closed-loop system. It was noted the power system voltage and system transfer is the desired number of values generated by the synchronous generator. The connection between the system and computer has been provided by PCI 1716 DAQ card, computer hardware connection. A synchronous machine speed and load has been made by using the MATLAB version 10.0, depending on the type of voltage control. A control model has been created by using Real Time Toolbox and Simulink at MATLAB. PID controller which is being in the library program is used in this control model. Voltage and speed in comparison with the reference value is applied and the resulting error of PID controller in the form of system response data has been obtained. These data are plotted in MATLAB using the system response curves.Disruptive effect on the system as ohmic, inductive, capacitive loads have been used. The system was first activated when there is no load (empty) operated. The second consisting only of resistors and three phase, star-connected load has been commissioned. Of the third resistance and the coil of three-phase, star-connected load has been commissioned. Resistors and capacitors of the fourth three-phase, star-connected load has been commissioned. The fifth and last study, the resistor, inductor and capacitors of the three-phase, star-connected load has been commissioned.In these studies, the number of cycles of the system voltage and the PID charts are examined and it has been registered that applied to the system auditing value of the reference value of the synchronous machine voltage and speed in a short time settled revealed graphics.Revolution speed setting of DC motor and alerting current of synchronous generator are provided by the optically isolated analog output card. This card sets control signal of DC motor and the alerting of synchronous generator according to signals which come from the analog output of the control model. The main charcteristic of this card is isolation of experimental system from cards.

Benzer Tezler

  1. Multi-objective optimization of swirl burner with premixed ammonia/hydrogen flame

    Ön karışımlı amonyak/hidrojen alevine sahip girdaplı yakıcının çok hedefli optimizasyonu

    MEHMET ANIL GÜLŞAN

    Doktora

    İngilizce

    İngilizce

    2026

    Makine Mühendisliğiİstanbul Teknik Üniversitesi

    Makine Mühendisliği Ana Bilim Dalı

    PROF. DR. YAKUP ERHAN BÖKE

  2. Experimental investigation of an oscillating tandem-wing power generator

    Ardaşık yerleştirilmiş çırpan kanatlı enerji üreticinin deneysel incelenmesi

    FERHAT KARAKAŞ

    Yüksek Lisans

    İngilizce

    İngilizce

    2016

    Uçak Mühendisliğiİstanbul Teknik Üniversitesi

    Uçak ve Uzay Mühendisliği Ana Bilim Dalı

    ÖĞR. GÖR. İDİL FENERCİOĞLU AYDIN

  3. Yer altında kömür gazlaştırma için teorik model geliştirilmesi ve deneysel çalışmalar ile sonuçların yorumlanması ve karşılaştırılması

    Development of a mathematical model and experimental work and comments on the results for the underground coal gasification process

    AHMET YILDIZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2015

    Enerjiİstanbul Teknik Üniversitesi

    Makine Ana Bilim Dalı

    PROF. DR. MESUT GÜR

  4. Spatial-behavioral dynamics in varied urban configurations during emergencies: An integrated VR-ABM approach to disaster resilience

    Acil durumlarda farklı kentsel ortamlardaki mekânsal ve davranışsal dinamikler: Afet dayanıklılığı için entegre bir VR-ABM yaklaşımı

    DUYGU KALKANLI

    Doktora

    İngilizce

    İngilizce

    2026

    Şehircilik ve Bölge Planlamaİstanbul Teknik Üniversitesi

    Şehir ve Bölge Planlama Ana Bilim Dalı

    PROF. DR. SEDA KUNDAK

  5. Üniversite yerleşkesinde oluşan yemekhane atıkları ile gerçek ölçekli biyometanizasyon tesisinde biyogaz üretimi

    Biogas production at full scale biomethanizition plant from food waste generated at university campus

    ENES AĞUŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MAHMUT ALTINBAŞ