Güvenli Havayolu Sağlanmasında `Klasik LMA', `Proseal LMA' ve `Cobra PLA'nın Karşılaştırılması
Comparison of the `Classic LMA?, `Proseal LMA? and `Cobra PLA? for Maintaining Airway Safety
- Tez No: 289275
- Danışmanlar: PROF. DR. HÜLYA BİLGİN
- Tez Türü: Tıpta Uzmanlık
- Konular: Anestezi ve Reanimasyon, Anesthesiology and Reanimation
- Anahtar Kelimeler: Genel anestezi, laringeal maske, etkin ventilasyon, yan etkiler, General anaesthesia, laryngeal mask airway, adequate ventilation, adverse effects
- Yıl: 2008
- Dil: Türkçe
- Üniversite: Uludağ Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Anesteziyoloji ve Reanimasyon Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Çalışmamızda 3 supraglottik havayolu aracını; klasik laringeal maske (LMA), proseal LMA ve cobra perilaringeal havayolunu (PLA) yerleştirme zamanı ve başarı oranı, etkin ventilasyon sağlama, hemodinamik değişkenler ve postoperatif komplikasyonlar açısından karşılaştırmayı amaçladık.Etik kurul onayı sonrasında, elektif cerrahi geçirecek ASA I-II, 90 hasta çalışmaya alındı. Hastalar rastgele klasik LMA, proseal LMA ve cobra PLA olmak üzere üç gruba ayrıldı. Anestezi indüksiyonu propofol (2.5 mg/kg i.v.), fentanil (2 µg/kg i.v.) ve vekuronyum bromür (0.6 mg/kg i.v.) ile sağlandı. Anestezi idamesinde %50 O2+N2O ve %2 sevofluran kullanıldı. Hemodinamik veriler operasyon boyunca kaydedildi. Havayolu araçlarının yerleştirme ve ventilasyon özellikleri, anestezistin memnuniyeti ve postoperatif komplikasyonlar kaydedildi. İstatistiksel analiz için veriler bağımlı örneklem t-testi, Pearson ki-kare testi veya Fisher'in kesin ki-kare testi ile karşılaştırıldı. p<0.05 değeri istatistiksel olarak anlamlı kabul edildi.Yerleştirme süreleri klasik LMA, proseal LMA ve cobra PLA için sırasıyla 28.9 sn, 33.14 sn ve 32.25 sn idi. Klasik LMA diğer 2 grupla karşılaştırıldığında yerleştirme zamanı daha kısaydı (p<0.001). Toplam başarılı yerleştirme oranları klasik LMA için %100, proseal LMA için %93 ve cobra PLA için %90 olarak saptandı. Anestezist memnuniyeti yönünden cobra PLA diğer 2 grupla karşılaştırıldığında memnuniyet daha kötü olarak saptandı (p<0.05). Hemodinamik veriler, etkin ventilasyon özellikleri, postoperatif yan etkiler açısından 3 grup karşılaştırıldığında da istatistiksel anlamlı farklılık yoktu (p>0.05).Her 3 havayolu aracının genel anestezi uygulanan hastalarda yeterli havayolu sağlamada etkili olduğu gözükmektedir. Proseal LMA ve cobra PLA anestezi uygulanmış hastalarda güvenli ve etkili havayolu sağlamada klasik LMA'ya alternatif olarak kullanılabilir.
Özet (Çeviri)
In our study we aim to compare the insertion time and success rate, adequacy and sealing quality, postoperative airway complications and haemodynamic variables of three supraglottic airway devices; classic LMA (LMA), proseal LMA and the cobra perilaryngeal airway (PLA).After obtaining ethics committee approval, ninety patients (ASA I-II) scheduled for elective surgery were randomized to receive a classic LMA, proseal LMA or cobra PLA. All patients received a standardized induction with propofol (2.5 mg/kg i.v.), fentanil (2 µg/kg i.v.) and vecuronium bromide (0.6 mg/kg i.v.). %50 O2+N2O ve %2 sevoflurane was used for anaesthesia maintenance. Haemodynamic measurements were recorded during surgery. Insertion and ventilation characterictics of airway devices, opinion of anesthesiologist and postoperative complications were also evaluated. Data were compared with unpaired t-tests, chi-square tests or Fisher?s Exact tests; value p< 0.05 was considered statistically significant.Insertion times were 28.9 sn, 33.14 sn and 32.25 sn for classic LMA, proseal LMA and cobra PLA. Total insertion time was shorter with classic LMA when compared with the other 2 groups (p<0.001). Successful insertion rates were %100 for the classic LMA, %93 for proseal LMA and % 90 for cobra PLA. The opinion of the anaesthesiologist about the devices is worse with cobra PLA when compared with the other 2 groups (P<0.05). There were no significant differences between the groups in haemodynamic measurements, adequate ventilation parameters, postoperative adverse events (p>0.05).Each 3 airway devices appeared to be effective in establishing an adequate airway in patients underwent general anaesthesia. Proseal LMA and cobra PLA can be used as an alternative to classic LMA to establish a safe and effective airway in anaesthetized patients.
Benzer Tezler
- I-gel ve laringeal mask airway-supreme'in klinik performans yönünden karşılaştırılmaı: Prospektif çalışma
Comparison of I-gel and laryngeal mask airway-supreme in terms of clinical performance: A prospective study
RAMIN VERDIKHANOV
Tıpta Uzmanlık
Türkçe
2021
Anestezi ve ReanimasyonEge ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
PROF. IŞIK ALPER
- The effects of self-service technology-related characteristics on brand experience and customer satisfaction at airports
Havalimanlarında bulunan self servis teknolojileri ile ilgili özelliklerin marka deneyimine ve müşteri memnuniyetine etkileri
SENA KILIÇ
Yüksek Lisans
İngilizce
2019
Sivil Havacılıkİstanbul Teknik Üniversitesiİşletme Ana Bilim Dalı
DOÇ. DR. ELİF KARAOSMANOĞLU
- Hacettepe Üniversitesi Tıp Fakültesi ameliyathane ve ayılma ünitesinde karşılaşılan zor entübasyon vakalarının incelenmesi
Hacettepe University Medical Faculty operations and investigation of the complexed difficult obstruction circulations
ADNAN MENDERES VURAL
Tıpta Uzmanlık
Türkçe
2016
Anestezi ve ReanimasyonHacettepe ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
DOÇ. DR. İSMAİL AYDIN ERDEN
- Avrupa Topluluğu'nda ulaştırma sektöründe yaşanan sıkıntılar ve üçüncü dünya ülkelerinin uyum sorunları, Türkiye örneği
Başlık çevirisi yok
ÖMER CAN KURTULDU
- Havayolu taşımacılığında üretkenlik karşıtı davranışlar ve kabin görevlilerinin algısı üzerine bir araştırma
Counterproductive workplace behavior in air transportation organizations and a research on cabin crew
K. GÜLNAZ BÜLBÜL
Yüksek Lisans
Türkçe
2013
İşletmeAnadolu ÜniversitesiSivil Havacılık Yönetimi Ana Bilim Dalı
YRD. DOÇ. DR. NALAN ERGÜN