Application of ultrafiltration to an organized industrial district wastewater treatment plant effluent for water reuse
Organize sanayi bölgesi atık su arıtma tesisi çıkış sularının yeniden kullanımı için ultrafiltrasyon uygulaması
- Tez No: 283553
- Danışmanlar: DOÇ. DR. NURDAN BÜYÜKKAMACI
- Tez Türü: Yüksek Lisans
- Konular: Çevre Mühendisliği, Environmental Engineering
- Anahtar Kelimeler: Membranlar, Organize endüstri bölgesi, Ultrafiltrasyon, Yeniden kullanma, Membranes, Organized industrial area, Ultrafiltration, Reuse
- Yıl: 2010
- Dil: İngilizce
- Üniversite: Dokuz Eylül Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu çalışmada, Organize Sanayi Bölgesi (OSB) Atıksu arıtma Tesisinden çıkan arıtılmış suların Ultrafiltrasyon (UF) sistemi kullanılarak yeniden kullanımını araştırmak hedeflenmiştir. Pilot tesis olarak seçilen OSB Atıksu Arıtma Tesisi son çökeltim ünitesi çıkışından numuneler alınmış ve UF membran sistem olarak ?Prep/Scale Spiral Wound Ultrafiltrasyon Modülü (Millipore)? seçilmiştir. UF membran sisteminde rejenere selüloz maddeden yapılmış, moleküler ağırlık kesim boyutu (MWCO) 100 kDa, 30 kDa ve 1 kDa olan üç farklı membran kartuş kullanılmıştır. Membran sistemi çıkış sularının özellikleri KOİ, AKM, pH ve iletkenlik parametreleri göz önünde bulundurularak değerlendirilmiştir. Sistemde 0-2 bar aralığında membran geçiş basınçları (TMP) uygulanmıştır. Elde edilen sonuçlara göre, UF membran çalışmaları AKM gideriminde oldukça etkili olmuştur ancak KOİ giderimi yeterli değildir. UF uygulamasından sonra maksimum %67 KOİ giderme verimi sağlanmıştır. Aynı şekilde belirgin bir iletkenlik düşüşü gözlenmemiştir. Deneysel çalışmaların sonuçlarına göre; mevcut atıksu arıtma tesisi çıkış sularının denenen ultrafiltrasyon membran sistemine verilmesi durumunda incelenen OSB içerisinde yer alan bazı endüstriler için uygun kalitede proses suyu elde edilemediği, bu şekilde daha iyi kalitede suya ihtiyaç duyan endüstriler için daha farklı ileri arıtma metotlarının kullanılması gerekliliği olduğu sonucuna varılmıştır.
Özet (Çeviri)
In this study, it is intended to investigate the possibility of reusing the effluents originated from Organized Industrial District (OID) Wastewater Treatment Plant as process water after ultrafiltration. Secondary treatment effluent samples were taken from an OID, which was selected as pilot plant, and Prep/Scale Spiral Wound Ultrafiltration Modules (Millipore) were chosen as UF membrane system. Three different sizes of UF membrane cartridges with a molecular weight cut-off (MWCO) of 100 kDa, 30 kDa, and 1 kDa, which are made form regenerated cellulose material, were used. The effect of ultrafiltration on polishing of secondary treatment effluent of OID was evaluated in terms of chemical oxygen demand (COD), suspended solid (SS), electrical conductivity (EC), and pH depending on transmembrane pressure (TMP), which varied between 0 to 2 bars. The results indicated that examined UF membranes are very effective for SS removal; however removal of organics is not sufficient. After UF applications, maximum 67% COD removal efficiency could be obtained. Similarly, significant EC reduction could not be achieved. Therefore, the quality of permeates can not meet the requirements of some industries located in the OID and further treatment should be applied before reuse depending on the required process water qualities.
Benzer Tezler
- Tavuk tüylerinden büyük ölçekte keratinaz üretimi ve ayırma saflaştırma işlemleri
Large scale keratinase prduction from chicken feathers and seperation and purification processes
İREM DENİZ
Doktora
Türkçe
2017
BiyomühendislikEge ÜniversitesiBiyomühendislik Ana Bilim Dalı
PROF. DR. FAZİLET VARDAR
- Application of an anaerobic biomembrane system on the treatment of high strength industrial wastewaters
Konsantre organik kirliliğe sahip endüstriyel atıksularının arıtımında anaerobik biyomembran sistemi uygulaması
YUNUS AKSOY
Yüksek Lisans
İngilizce
2012
Çevre MühendisliğiDokuz Eylül ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
PROF. DR. NURDAN BÜYÜKKAMACI
- Application of membrane processes for whey treatment
Peynir altı suyu arıtımında membran prosesleri uygulaması
MUHARREM SONER YORGUN
Yüksek Lisans
İngilizce
2005
Çevre MühendisliğiBoğaziçi ÜniversitesiPROF. DR. IŞIL BALCIOĞLU
PROF. DR. ÖMER SAYGIN
- Application of dynamic membranes in anaerobic membrane bioreactor systems
Anaerobik membran biyoreaktör sistemlerinde dinamik membranların uygulanması
MUSTAFA EVREN ERŞAHİN
Doktora
İngilizce
2015
Çevre Mühendisliğiİstanbul Teknik ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
PROF. DR. İZZET ÖZTÜRK
- Fabrication of forward osmosis membrane and its application after membrane bioreactor
İleri osmoz membran üretimi ve membran biyoreaktör sonrası uygulanması
SEDA GAZİOĞLU
Yüksek Lisans
İngilizce
2017
Çevre Mühendisliğiİstanbul Teknik ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
PROF. DR. İSMAİL KOYUNCU