Normal bireylerde ve keratokonus olgularında Pentacam HR ve Orbscan II ölçümlerinin karşılaştırılması

Comparison of Orbscan II and Pentacam HR in Normal and Keratoconus

  1. Tez No: 281925
  2. Yazar: ENDER GÖLEMEZ
  3. Danışmanlar: PROF. DR. NİLGÜN YILDIRIM
  4. Tez Türü: Tıpta Uzmanlık
  5. Konular: Göz Hastalıkları, Eye Diseases
  6. Anahtar Kelimeler: keratokonus, kornea, topografi, pentacam, orbscan, Göz hastalıkları, Korneal hastalıklar, Teşhis teknikleri ve prosedürleri, Tıbbi araç-gereç ve donanımlar, keratoconus, cornea, topography, pentacam, orbscan, Eye diseases, Corneal diseases, Diagnostic techniques and procedures, Equipment and supplies
  7. Yıl: 2011
  8. Dil: Türkçe
  9. Üniversite: Eskişehir Osmangazi Üniversitesi
  10. Enstitü: Tıp Fakültesi
  11. Ana Bilim Dalı: Göz Hastalıkları Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Eskisehir Osmangazi Üniversitesi Tıp Fakültesi Hastanesi Göz Hastalıkları Anabilim Dalına başvuran çalışma kriterlerine uygun ve katılma onamı veren 193 olgunun 193 gözü değerlendirmeye alındı. Olgular kontrol grubu (n=100), evre I keratokonus (n=45), evre II keratokonus (n=22) evre III keratokonus (n=14) ve evre IV keratokonus (n=12) olarak gruplandırıldı. Her olguya tam oftalmolojik muayene yapıldıktan sonra Orbscan II ve Pentacam HR cihazı ile kornea topografi ölçümleri aynı gün içersinde 2 kez olacak şekilde tekrarlandı. Keratokonus olgularının normal olgulardan ayırımında ve keratokonus olgularının gruplanmasında her iki cihaz da yüksek hassasiyet göstermekteydi. Orbscan II cihazı pakimetri ölçümlerinde daha ince ve başta arka yüzey olmak üzere elevasyon değerlerinde daha yüksek değerler vermekte böylece keratokonus hastalarının ve refraktif cerrahi adaylarının değerlendirilmesinde Pentacam HR cihazına göre daha ektazik bir tavır sergilemektedir. Bu nedenle keratokonus tanısı, refraktif cerrahi öncesi ve sonrası değerlendirmede Pentacam HR daha güvenilirdir. Pentacam HR cihazı Orbscan II cihazına göre elevasyon parametreleri ve pakimetrik parametreler açısından daha iyi bir tekrarlanabilirlik göstermektedir.Pentacam HR cihazı ile normal ve keratokonus ayırımında sırasıyla pakimetri, elevasyon ve ardından keratometri parametreleri daha çok yardımcı olmaktadır.En değerli parametreler olarak sırasıyla minimum pakimetri, maksimum arka elevasyon, santral kornea kalınlığı ve maksimum ön elevasyon dikkati çekmektedir.

Özet (Çeviri)

193 eyes of 193 patients were analyzed in the present study. Patients were recruited from the Ophthalmology Department of Eskişehir Osmangazi University Faculty of Medicine. Subjects were grouped as control (n=100), grade I keratokonus (n=45), grade II keratokonus (n=22) grade III keratokonus (n=14) and grade IV(n=12) keratokonus. After full ophthalmologic examination, corneal topography with Orbscan II and Pentacam HR was evaluated for each subject 2 times. Both of the devices showed high sensitivity for distinguishing keratoconus from normal subjects. Orbscan II can mimic like ectasia in keratoconus subjects and refractive surgery candidates with thinner pachymetric values and higher elevation values. Pentacam HR is more reliable in assessment before and after refractive surgery and keratoconus patients. Pentacam HR shows better reproducibility especially in elevation and pachymetric values. In distinguishing keratoconus from normal subjects; pachymetric, elevation and keratometric parameters are useful respectively. Most valuable parameters are minimum pachymetry, maximum posterior elevation, central corneal thickness and maksimum anterior elevation respectively.

Benzer Tezler

  1. Normal ve keratokonik kornea morfolojik özelliklerinin dual-scheimpflug kamera ile değerlendirilmesi

    Evaluation of morphological characteristics of normal and keratoconic corneas using dual-scheimpflug camera

    SELİM DEMİR

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2010

    Göz HastalıklarıOndokuz Mayıs Üniversitesi

    Göz Hastalıkları Ana Bilim Dalı

    DOÇ. DR. BARIŞ SÖNMEZ

  2. Keratokonuslu ve normal bireylerdeki plazma homosistein, vitamin b12 ve folik asit düzeylerinin kıyaslanması

    Comparing the plasma homocysteine, vitamin B12 and folic acid levels in keratoconus and normal individuals

    MEHMET YILMAZ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2017

    Göz HastalıklarıÇanakkale Onsekiz Mart Üniversitesi

    Göz Hastalıkları Ana Bilim Dalı

    YRD. DOÇ. DR. SEDAT ARIKAN

  3. Normal bireylerde panum alanı değerleri ve özellikleri

    Başlık çevirisi yok

    AYŞE GÜL KOÇAK

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    1992

    Göz HastalıklarıSağlık Bakanlığı

    Göz Hastalıkları Ana Bilim Dalı

    DR. SUNAY DUMAN

  4. Normal bireylerde ve geniş lif nöropatisi olmayan tip 2 diabetik hastalarda ince lif hasarının kantitatif duyusal test (KDT) ile değerlendirilmesi

    The assessment of small fiber damage in normal individuals and the patients with type 2 diabetes mellitus who have not large fiber neuropathy with quantitative sensory testing

    NAZİLE DOĞAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2009

    NörolojiAbant İzzet Baysal Üniversitesi

    Nöroloji Ana Bilim Dalı

    DOÇ. DR. NEBİL YILDIZ