Geri Dön

Farklı lokalizasyonlarda konumlandırılan mikro boşluğun implant çevresi oluk sıvısında İnterlökin-1 Beta Ve Tümör Nekrozis Faktör- Alfa seviyeleri üzerine etkisinin değerlendirilmesi

Effect of different localizations of microgap on alveolar crest on Interleukin-1 Beta and Tumor Necrosis Factor-Alpha Levels in peri-implant crevicular fluid

  1. Tez No: 260944
  2. Yazar: ALİYE DUYGU BOYNUEĞRİ
  3. Danışmanlar: PROF. DR. MEHMET YALIM
  4. Tez Türü: Doktora
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Periodontoloji, Protezler ve implantlar, Sitokinler, Periodontology, Prostheses and implants, Cytokines
  7. Yıl: 2009
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Periodontoloji Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı kemik seviyesine göre farklı lokalizasyonlarda konumlandırılan mikro boşluğun implant çevresi oluk sıvısında İnterlökin-1 Beta (IL-1beta) ve Tümör Nekrozis Faktör-Alfa (TNF-alfa) seviyelerinin üzerine etkisinin değerlendirilmesidir.Alt-üst çene tam dişsizliğe sahip 10 birey çalışmamıza dahil edilmiş ve hastalara alt çenede mental foraminalar arasına gelen bölgeye 4 adet implant uygulaması yapılmıştır. Bu implantlar 4 farklı gruba ayrılmıştır: grup A: Pürüzlü/ düz yüzey birleşiminin kemik seviyesinde konumlandırıldığı standart implantlar, grup B: Parlak yüzeyin kemik seviyesinin 1 mm. altına yerleştirildiği standart implantlar, grup C: Pürüzlü/ düz yüzey birleşiminin kemik seviyesinde konumlandırıldığı estetik plus implantlar ve grup D: Parlak yüzeyin kemik içerisine yerleştirildiği estetik plus implantlar.Hastaların yükleme öncesinde, 3. Ay, 6. Ay ve 12 aylarda klinik indeks ölçümleri kaydedilmiş ve implant çevresi oluk sıvıları (İÇOS) alınmıştır.Çalışma süresi boyunca gruplar arasında plak indeksi, gingival indeks ve cep derinliği açısından bir fark bulunamamıştır; fakat A grubundaki implantların İÇOS hacmi değerleri diğer tüm gruplardan daha düşüktür (p<0.05). Sondlamada kanama (BOP) değerlerine bakıldığında kanama gösteren bölgelerin yüzdesi A grubunda C ve D gruplarına göre daha düşüktür (p<0.05). IL-1beta seviyerine bakıldığında; A grubundaki implantlar diğer gruplara göre daha düşük oranda IL-1beta seviyelerine (p<0.05). Benzer şekilde TNF-alfa seviyeleri A grubu implantlarda diğer implant gruplarından daha düşüktür; bu fark B ve D grupları ile kıyaslandığında istatistiksel olarak anlamlıdır (p<0.05). Bu çalışmanın sonuçları kret seviyesinin koronalinde konumlandırılan mikro boşluğun periodontal dokuların sağlığı açısından tercih edilebilir bir tedavi seçeneği olduğunu düşündürmektedir.

Özet (Çeviri)

The purpose of this study was to evaluate the effect of microgap on clinical and biochemical parameters around dental implants for 1 year.All patients received four implants: group A: Standard ITI implants, group B: 1 mm. subcrestal placement of the polished surface of group A implants, group C: Esthetic plus ITI implants, group D: subcrestal placement of the polished surface of group C implants.Clinical measurements and Peri Implant Crevicular Fluid (PICF) were collected immediately before loading and at 3th, 6th, 12th months after loading.No significant differences were found in Plaque Index, Gingival Index and Probing Depths between the groups throughout the study. However, the PICF volumes of group D were significantly higher than those of group A, C,D and group A were significantly lower than those of group B, C,D (p<0.05). With respect to Bleeding on Probing (BOP) values; the percentage of BOP (+) sides in group A implants were fewer than group C and D implants (p<0.05). With regard to Interleukin-1 Beta (IL-1 beta), the levels of IL-1beta in group A were lower than the other groups during the study (p<0.05). In point of Tumor Necrosis Factor-Alpha (TNF-alpha) total amounts; the levels of TNF-alpha in group A implants were lower than those group B and D implants (p<0.05) showing that moving microgap coronally from alveolar crest could be recommended for the health of periodontal tissues.

Benzer Tezler

  1. Buğdayda farklı melezleme teknikleri kullanarak tohum tutma oranının saptanılması

    Başlık çevirisi yok

    İSMAİL TÜZÜN

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    ZiraatUludağ Üniversitesi

    Tarla Bitkileri Ana Bilim Dalı

    PROF. DR. HALİS RUHİ EKİNGEN

  2. Diyabetus mellitus'da gözlenen mikrovasküler komplikasyonların prostaglandinler ile olan ilişkisi

    The Relation of microvaskular complications observed in diabetes mellitus with prostoglandins

    CANAN NEBİGİL

    Doktora

    Türkçe

    Türkçe

    1985

    Eczacılık ve FarmakolojiCumhuriyet Üniversitesi

    Farmakoloji Ana Bilim Dalı

    YRD. DOÇ. DR. YUSUF SARIOĞLU

  3. Bazı esterlerin kinetik incelenmesi ve termodinamik parametrelerin belirlenmesi

    Kinetic study and detesmination of thermodnamic parameters of some esters

    İBRAHİM TAŞ

    Yüksek Lisans

    Türkçe

    Türkçe

    1986

    Kimya MühendisliğiUludağ Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. MUSTAFA CEBE

  4. Çoklu amaçların çözümlemesinde amaç programlaması ile genelleştirilmiş ters yaklaşımı ve yem sanayiinde bir uygulama

    Goal programming and generalieed inverse approaches in the multi-objective analysis and application in feed industry

    HASAN BAL

    Doktora

    Türkçe

    Türkçe

    1986

    İstatistikGazi Üniversitesi

    İstatistik Ana Bilim Dalı

    DOÇ. DR. FEVZİ KUTAY