Geri Dön

İki farklı güçte uygulanmış Er:YAG laser ile hazırlanan dentin yüzeylerine self-etch veya total-etch olan üç farklı rezin siman ile bağlanan porselen yüzeylerinin in-vitro bağlanma dayanımı

Shear bond strength of porcelain bonded to Er:YAG laser prepared dentin with self-etch and total-etch resin cements

  1. Tez No: 247203
  2. Yazar: KORALP GÜNER
  3. Danışmanlar: DOÇ. DR. ARZU AYKOR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Diş Hekimliği, Dentistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2009
  8. Dil: Türkçe
  9. Üniversite: Yeditepe Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Diş Hastalıkları ve Tedavisi Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Bu çalışmanın amacı, farklı güçte Er:YAG lazer uygulanmış dentin yüzeylerine porselen blokların 3 farklı rezin siman ile simante edilmesinden sonra makaslama kuvvetlerine bağlanma dayanımının in vitro olarak incelenmesi ve oluşturulan test gruplarının SEM görüntülerinin değerlendirmesidir.45 adet sürmemiş üçüncü büyükazı dişi kullanılmıştır. Tüm periodontal artıklar küret yardımı ile uzaklaştırıldıktan sonra dişlerin kuronları köklerinden ayırıldı ve ortadan ikiye bölünüp 90 adet örnek hazırlanmıştır. Akrilik rezin içerisine gömülen dişlerin bukkal ve lingual yüzeyleri 600 grit silikon karbid zımpara kağıtlar yardımıyla su altında, 4 mm dentin kalınlığı elde edilinceye kadar zımparalanmıştır. Dentin açığa çıkarıldıktan sonra üç gruba Er:YAG lazer ile 30 Hz/70 mJ, üç gruba 30 Hz/160 mJ lazer uygulanmıştır. Kalan 3 gruba ise lazer uygulaması yapılmamış ve her rezin simanın kontrol grupları oluşturulmuştur. Tüm örnekler 4 mm çapında 2 mm yükseklikte Empress II silindir porselen blokları üç farklı rezin siman ile (Kuraray Esthetics [Self-etch], Ivoclar Multilink Automix [Self-etch] ve Ivoclar Variolink II [Total-etch]) üretici firmaların önerileri doğrultusunda dentin disklerine simante etmek amacı ile, her grupta 10 adet örnek olmak üzere, rastgele 9 alt gruba ayrılmıştır. Tüm örneklere 5?-55?C arasında 1000 kez termosiklus döngüsü uygulanmıştır. Universal test cihazına (Instron; USA) bağlanan örneklere, 1mm/dak hız uygulanarak kopma meydana gelene kadar makaslama kuvveti uygulanmış, ve kırılan örneklerin kopma değerleri MPa olarak kayıt edilmiştir. İstatistiksel analiz için Dunn ve çoklu değişken testleri ve Kruskal Wallis testleri uygulanmıştır.Variolink II ve Multilink Automix rezin simanları, Clearfil Esthetic Cement'ten istatistiksel olarak anlamlı fark göstererek daha iyi sonuç vermiştir. Variolink II ve Multilink Automix rezin simanlarının test ve kontrol gruplarında elde edilen bağlanma değerleri klinik olarak kabul edilebilir olarak yorumlanmıştır.Lazer uygulamaları, Variolink II ve Clearfil Esthetic Cement'in test gruplarında kontrol grubuna göre istatistiksel anlamlı fark yaratmazken, Multilink Automix gruplarında bağlanma değerlerini istatistiksel anlamlı fark göstererek düşmüştür. Ancak bu değerler klinik olarak kabul edilebilir bağlanma kuvvetlerinin altına düşmediği gözlemlenmiştir

Özet (Çeviri)

The objective of this study was an in vitro investigation of the shear strength of the bonding where porcelain blocks are cemented using three different resin cements on dentine surfaces subjected to laser applications with different densities.Investigation was carried out using 45 extracted, unerupted human wisdom teeth. Following the removal of the periodontal residue using a curette, the crown of each tooth was separated from its roots and then each tooth was cut into two equal parts providing total of 90 test specimens. Each specimen was then embedded into acyrilic resin housed in a brass cylinder (diameter 20 mm, height 16 mm). Buccal and lingual surfaces of each specimen were ground under water using using 600 grid silicon carbide grinding paper to ensure 4-5 mm dentin thickness. After complete exposing of the dentin surfaces, three groups of specimens were applied Er:YAG laser of 30Hz/70mJ density and another three groups of specimens were applied Er:YAG laser of 30Hz/160mJ density. The remaining three groups of specimens were not subjected to any laser application since these groups were intended as reference (control) groups.A cylinder shaped porcelain block (diamater 4mm, height 2 mm) was cemented to each one of 90 specimens using three different resin cements in accordance with their manufacturers? recommendations; Kuraray Clearfil Esthetic Cement (Self-Etch), Ivoclar Multilink Automix (Self-Etch) and Ivoclar Variolink II (Total-Etch). Then, the specimens were randomly selected and grouped into 9 groups where each group contained 10 specimens. All the specimens were then subjected to an accelerated aging process in a thermo-cycle unit for 1,000 cycles between 5 and 55 degrees Celcius. The specimens were then tested in a Universal Testing Machine (Instron, USA) subjecting them to a shear force applied at 1 mm / second rate until the shear failure occured. A level of shear force at the instant of failure of each specimen was recorded in MPa. The statistical analysis was performed using Dunn?s multiple variable and Kruskal Wallis tests.The specimens bonded using Variolink II and Multilink Automix resin cements showed statistically meaningful differences with respect to the specimens bonded using Clearfil Esthetics Cement and thus giving better results.

Benzer Tezler

  1. Kronik kalp yetmezlikli hastalarda sürekli ve interval tipte aerobik egzersiz programlarının etkinliğinin karşılaştırılması

    Comparıson of the effıcıencıes of contınuous and ınterval-type aerobıc exercıse on the patıents with chronıc heart faılure

    SİBEL KONUKCU

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2013

    Fiziksel Tıp ve RehabilitasyonPamukkale Üniversitesi

    Fiziksel Tıp ve Rehabilitasyon Ana Bilim Dalı

    YRD. DOÇ. DR. GÜLİN FINDIKOĞLU

  2. Laparoskopik kolesistektomi uygulanacak hastalarda erektör spina plan bloğu ile intraperitonenal lokal anestezik instilasyonunun postoperatif iyileşme kalitesi üzerine etkisinin karşılaştırılması

    Comparison of the effects of erector spinae plane block and intraperitoneal local anesthetic instillation on the quality of postoperative recovery in patients undergoing laparoscopic cholecystectomy

    HAKAN DUZLA

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2024

    Anestezi ve ReanimasyonAnkara Üniversitesi

    Anesteziyoloji ve Reanimasyon Ana Bilim Dalı

    DOÇ. DR. MENEKŞE ÖZÇELİK

  3. Vibration and flutter analysis of fluid loaded plates

    Akışkan yüklü eğimli plakların titreşim ve flater analizi

    ABDURRAHMAN ŞEREF CAN

    Yüksek Lisans

    İngilizce

    İngilizce

    1996

    Uçak Mühendisliğiİstanbul Teknik Üniversitesi

    DOÇ.DR. ZAHİT MECİTOĞLU

  4. Analysis of slotted sectoral waveguide antenna arrays embedded in cylindrically stratified media

    Silindirik katmanlı ortamlarda sektörel yarıklı dalga kılavuzu dizi antenlerin analizi

    MERT KALFA

    Yüksek Lisans

    İngilizce

    İngilizce

    2013

    Elektrik ve Elektronik Mühendisliğiİhsan Doğramacı Bilkent Üniversitesi

    Elektrik ve Elektronik Mühendisliği Bölümü

    DOÇ. DR. VAKUR BEHÇET ERTÜRK

  5. Sağlık okuryazarlığının gebelik ve sağlık algısı ile ilişkisi

    The relationship between health literacy, pregnancy and perception of health

    EMEL FİLİZ

    Doktora

    Türkçe

    Türkçe

    2015

    Halk SağlığıSelçuk Üniversitesi

    Halk Sağlığı Ana Bilim Dalı

    PROF. DR. ABDURRAHMAN SAİD BODUR