Bilgisayar destekli sıvılı düzlemsel güneş kollektörlerinin optimizasyonu
Compute aided optimization of liguid flat-plate solar colectors
- Tez No: 24322
- Danışmanlar: PROF. DR. GÜRBÜZ ATAGÜNDÜZ
- Tez Türü: Yüksek Lisans
- Konular: Enerji, Energy
- Anahtar Kelimeler: Bilgisayar destekli, Güneş toplayıcıları, Kollektörler, Optimizasyon, Computer aided, Solar collectors, Collectors, Optimization
- Yıl: 1992
- Dil: Türkçe
- Üniversite: Ege Üniversitesi
- Enstitü: Güneş Enerjisi Enstitüsü
- Ana Bilim Dalı: Enerji Teknolojisi Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Abstract Of M.S. Thesis COMPUTER AIDED OPTIMIZATION OF LIQUID FLAT-PLATE SOLAR COLLECTORS M.S. Student : Hüseyin GONERHAN Supervisor : Prof. Dr. -Ing. Gürbüz ATAGÜNDüZ Abstract In Turkey the most common usage of natural and inexhaustible solar energy is done by liquid flat-plate collectors. There is no need complicated technology for manufacturing flat-plate collectors. Therefore there are cheaper than the other systems. In general they consist of one glass cover, one absorber plate which bears pipes, insulation material and one frame. Heat ing and hot water demand have been supplied by liquid flat- plate collectors. * Although in Turkey collectors are manufactured according to Turkish Standarts (TS 3680, TS 3817, TS 4801) one can find collectors with different quality and different sizes. In this present work, under all other constant remaining conditions, i.e., one or two parameters are taken variable and the others kept constant, the influence of the number of pipes, the distance between two pipes, the ratio of width/length of the collector and the material of the absorber plate on the thermal efficiency coefficient and the heat collected by the collector has been investigated theoretically using experimental data. The aim of this work is the design of an optimum liquid flat-plate solar collector with suitable properties such as width/lenght ratio, number ofpipes, distance between two pipes and material. In previous research works, the influence of the material, the material of absorbing plate, the thickness of the absorbing plate, the convective heat transfer coefficient in pipes; the liquid velocity in pipes, the geometry of pipes, the distance between the glass cover and the absorbing plate, the liquid properties, the insulation material and their thickness and the overall heat transfer coefficient on the thermal efficiency coefficient has been investigated, but the ratio of width/length, number of pipes and the distance between two pipes have been not discussed. In addition, at the moment, classically manufactured collectors by the firms which are available in the market have been investigated for the months May, June, July, August and September where the thermal efficiency coefficient curves have been compared under each other and the best thermal efficiency coefficient curve has been determined. In the 1st part of the present work mathematical modelling has been done which bases on the fin theory. By means of the fin theory correlation the outlet temperature of the water and the thermal efficiency coefficient have been calculated. In the second part of the work experiments, in the 3rd part the investigations in details and in the 4th part the results have been discussed. At the end this investigation it has been seen that the thermal efficiency coefficient of a liquid flat-plate solar collector is function of following parameters: - Material of absorbing plate and pipes, - Number of pipes, - The distance between two pipes, - The ratio of width/length, - Outside temperature, - The solar radiation intensity. The optimum liquid flat-plate collector has been obtained for the following data: - Width/Lenght = 1.4/1.4 = 1.0, - Number of pipes =13, - The distance between two pipes = 0.1038 m, - Material of the collector = Copper. The months in which the best thermal efficiency coefficient curve has been obtained are June and July.
Özet (Çeviri)
Abstract Of M.S. Thesis COMPUTER AIDED OPTIMIZATION OF LIQUID FLAT-PLATE SOLAR COLLECTORS M.S. Student : Hüseyin GONERHAN Supervisor : Prof. Dr. -Ing. Gürbüz ATAGÜNDüZ Abstract In Turkey the most common usage of natural and inexhaustible solar energy is done by liquid flat-plate collectors. There is no need complicated technology for manufacturing flat-plate collectors. Therefore there are cheaper than the other systems. In general they consist of one glass cover, one absorber plate which bears pipes, insulation material and one frame. Heat ing and hot water demand have been supplied by liquid flat- plate collectors. * Although in Turkey collectors are manufactured according to Turkish Standarts (TS 3680, TS 3817, TS 4801) one can find collectors with different quality and different sizes. In this present work, under all other constant remaining conditions, i.e., one or two parameters are taken variable and the others kept constant, the influence of the number of pipes, the distance between two pipes, the ratio of width/length of the collector and the material of the absorber plate on the thermal efficiency coefficient and the heat collected by the collector has been investigated theoretically using experimental data. The aim of this work is the design of an optimum liquid flat-plate solar collector with suitable properties such as width/lenght ratio, number ofpipes, distance between two pipes and material. In previous research works, the influence of the material, the material of absorbing plate, the thickness of the absorbing plate, the convective heat transfer coefficient in pipes; the liquid velocity in pipes, the geometry of pipes, the distance between the glass cover and the absorbing plate, the liquid properties, the insulation material and their thickness and the overall heat transfer coefficient on the thermal efficiency coefficient has been investigated, but the ratio of width/length, number of pipes and the distance between two pipes have been not discussed. In addition, at the moment, classically manufactured collectors by the firms which are available in the market have been investigated for the months May, June, July, August and September where the thermal efficiency coefficient curves have been compared under each other and the best thermal efficiency coefficient curve has been determined. In the 1st part of the present work mathematical modelling has been done which bases on the fin theory. By means of the fin theory correlation the outlet temperature of the water and the thermal efficiency coefficient have been calculated. In the second part of the work experiments, in the 3rd part the investigations in details and in the 4th part the results have been discussed. At the end this investigation it has been seen that the thermal efficiency coefficient of a liquid flat-plate solar collector is function of following parameters: - Material of absorbing plate and pipes, - Number of pipes, - The distance between two pipes, - The ratio of width/length, - Outside temperature, - The solar radiation intensity. The optimum liquid flat-plate collector has been obtained for the following data: - Width/Lenght = 1.4/1.4 = 1.0, - Number of pipes =13, - The distance between two pipes = 0.1038 m, - Material of the collector = Copper. The months in which the best thermal efficiency coefficient curve has been obtained are June and July.
Benzer Tezler
- Bilgisayar kontrollu ultrasonik ölçme sistemi
Computer controlled ultrasonic measurement system
SELİM KARA
Yüksek Lisans
Türkçe
1997
Fizik ve Fizik MühendisliğiTrakya ÜniversitesiFizik Ana Bilim Dalı
DOÇ. DR. A. TANER OSKAY
- Bilgisayar destekli din öğretimi
Computer aided instruction in religious education
AŞKIN ASAN
Doktora
Türkçe
1998
Eğitim ve ÖğretimOndokuz Mayıs ÜniversitesiFelsefe ve Din Bilimleri Ana Bilim Dalı
PROF. DR. HÜSEYİN PEKER
- Analysis of impact test by the finite element program
Başlık çevirisi yok
HALİT FİLİK
Yüksek Lisans
İngilizce
1994
Makine MühendisliğiDokuz Eylül ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. HİRA KARAGÜLLE
- Uçak yapısında yorulma nedenli çatlakların takibi için bilgisayar programı
Computer code for tracking metal fatique based cracks in the aircraft structure
BÜLENT CANDAN
Yüksek Lisans
Türkçe
1997
Uçak MühendisliğiAnadolu ÜniversitesiSivil Havacılık Ana Bilim Dalı
PROF. DR. T. HİKMET KARAKOÇ
- Application of the 3G PCS technologies to the mobile subsystem of the next generation tactical communications systems
Üçüncü nesil PCS teknolojilerinin gelecek nesil taktik muharebe sistemlerinin gezgin altsistemine uyarlanması
ERDAL ÇAYIRCI
Doktora
İngilizce
2000
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolBoğaziçi ÜniversitesiBilgisayar Mühendisliği Ana Bilim Dalı
DOÇ. DR. CEM ERSOY