Geri Dön

Development of a new orthosis (neuro-orthosis) for the control of wrist movements in patients with carpal tunnel syndrome

Karpal tünel sendromunda el bileği hareketlerinin kontrolü için yeni bir ortezin (nöro-ortez) geliştirilmesi

  1. Tez No: 232146
  2. Yazar: ÜMİT UĞURLU
  3. Danışmanlar: PROF. DR. MEHMED ÖZKAN
  4. Tez Türü: Doktora
  5. Konular: Mühendislik Bilimleri, Romatoloji, Fiziksel Tıp ve Rehabilitasyon, Engineering Sciences, Rheumatology, Physical Medicine and Rehabilitation
  6. Anahtar Kelimeler: Elektrikle uyarma, Karpal tünel sendromu, Ortotik cihazlar, Electric stimulation, Carpal tunnel syndrome, Orthotic devices
  7. Yıl: 2008
  8. Dil: İngilizce
  9. Üniversite: Boğaziçi Üniversitesi
  10. Enstitü: Biyomedikal Mühendislik Enstitüsü
  11. Ana Bilim Dalı: Biyomedikal Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Statik el bileği ortezleri (SEO) bazı dezavantajlarına rağmen karpal tünel sendromunun (KTS) tedavisinde kullanılmaktadırlar. Alternatif bir yaklaşım olarak el bileği ekleminin hareketlerini kısıtlamak için aktif kapalı-döngü kontrol sistemi kullanılması önerilmiştir. Sistem belirli sınırlar içerisinde el bileği eklemi hareketlerini kısıtlamak için antagonist kasların elektriksel yolla uyarılması prensibine dayanmaktadır. Çalışmanın amacı önerilen ?nöro-ortez? (NeO) sisteminin, hastaya özel olarak yapılan SEO' ne kıyasla elin fonksiyon ve kuvvetinde daha az kısıtlanmaya neden olup olmadığını ve hareketleri kıstlayabilme becerisini belirlemekti.Sistemin KTS'lu hastalar üzerinde özel bir etkisi olup olmadığını belirlemek için vaka-kontrol çalışma düzeni tertip edilmiştir. Dominant eli sağ olan 31 gönüllü çalışmaya katılmıştır. Bunların 12'si KTS'u olan hastalar geriye kalanı sağlam deneklerdi. Üç ayrı test koşulunda katılımcıların sağ ellerinin fonksiyon, beceri ve kuvveti ölçülmüştür: ortezsiz, SEO ile ve NeO sistemiyle. El bileği eklemindeki hareketleri ölçmek için özel bir potansiyometrik elektronik açıölçer tasarlanmıştır. Tüm test koşullarında standardize edilmiş test cihazları ve yöntemleri kullanılmıştır. Beceri düzeyinin ölçülmesinde kullanılan bir alt testinin uygulanması esnasında NeO sistemi açık ve kapalıyken her yönde ulaşılan en büyük eklem hareket açıları kaydedilmiştir. SEO ve NeO test koşullarının sonunda, rahatsızlık düzeyi 10 cm.lik görsel ağrı ölçeği kullanılarak değerlendirilmiştir.SEO'leri ortezsiz test koşuluna kıyasla, ölçümlerin birçoğunda kısıtlanmaya neden olmuşlardır. NeO sistemide ölçümlerde bazı kısıtlanmalara neden olmuştur. Bununla birlikte SEO'lerine kıyasla daha az kısıtlayıcı olduğu belirlenmiştir. NeO sistemi el bileği hareketlerini daha önceden belirlenmiş sınırlar içerisinde tam olarak kısıtlayamamasına rağmen, nihai hareket açıklığının hala ?güvenli sınırlar? içerisinde olduğu görülmüştür. NeO sistemi genel olarak daha fazla rahatsızlığa neden olmuştur.

Özet (Çeviri)

Static wrist orthoses (SWOs) are used in carpal tunnel syndrome (CTS) with some drawbacks. As an alternate approach, an active closed-loop wrist control strategy was proposed to limit wrist movements. It was based on the electrical stimulation of antagonistic muscle(s) to prevent motion beyond preset limits. The purposes of the study were to determine whether the proposed ?neuro-orthosis? (NeO) system resulted in less restriction in the function and strength of the hand compared to custom-made SWOs and its ability to limit the wrist movements.A case-control study was designed. 31 right-handed volunteers participated in the study. 12 of them were patients with CTS, and the others were healthy subjects. Function, dexterity, and strengths were measured under three different testing conditions: without orthosis, with a SWO, and with the NeO system. Standardized test instruments and test procedures were used for all measurements. Maximum angles at each direction were recorded while the NeO system was on and off. At the end of the SWO and the NeO test conditions the level of discomfort were questioned by means of 10 cm visual analog scale.SWOs caused significant decrements in most of the tests with respect to the no-orthosis test condition. The NeO system also led to some limitations in the test scores. However it was found to be less constraining with respect to a SWO. Although the NeO was not able to strictly limit the movements into preset limit, the resulting movement range was still in the safe area. The NeO system resulted in more discomfort in general.

Benzer Tezler

  1. Alt ekstremite için aktif ortez ve IoT uygulaması geliştirilmesi

    Development of active orthesis and IoT application for the lower limb

    EMRE YILMAZ

    Yüksek Lisans

    Türkçe

    Türkçe

    2022

    Mekatronik MühendisliğiSakarya Uygulamalı Bilimler Üniversitesi

    Mekatronik Mühendisliği Ana Bilim Dalı

    DR. ÖĞR. ÜYESİ MUSTAFA ÇAĞRI KUTLU

  2. Pes ekinovaruslu bebeklerde aşil tenotomisi sonrası tendon iyileşmesinin ultrasonografik shear-wave elastografi ile incelenmesi

    Evaluation of achilles tendon healing after achilles tenotomy in pediatric patients with pes equinovarus by using ultrasound shear-wave elastography

    MEHMET AFŞİN KARAOĞLAN

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2021

    Ortopedi ve TravmatolojiSelçuk Üniversitesi

    Ortopedi ve Travmatoloji Ana Bilim Dalı

    DOÇ. DR. BAHATTİN KEREM AYDIN

  3. A smart RGB-D camera-based approach for real-time 3D object pose estimation and tracking for exoskeleton-assisted neurorehabilitation scenarios

    Exoskeleton (dış iskelet) destekli nörorehabilitasyon senaryoları için gerçek zamanlı 3D nesne poz tahmini ve takibine yonelik akıllı, RGB-D kamera tabanlı bir yaklaşım

    FABIO STROPPA

    Yüksek Lisans

    İngilizce

    İngilizce

    2013

    Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolPolytecnıco Dı Barı

    PROF. DR. VİTOANTONİO BEVİLACQUA

  4. Development of a new solver for nonlinear parabolic phenomena

    Başlık çevirisi yok

    H.SEÇİL ALTUNDAĞ

    Yüksek Lisans

    İngilizce

    İngilizce

    1990

    Mühendislik BilimleriOrta Doğu Teknik Üniversitesi

    Mühendislik Bilimleri Ana Bilim Dalı

    YRD. DOÇ. DR. AHMET N. ERASLAN

  5. Development of a new techniques in marble restoration

    Mermer restorasyonunda geliştirilmiş yeni teknikler

    DAMLA AFYON

    Yüksek Lisans

    İngilizce

    İngilizce

    1996

    MimarlıkDokuz Eylül Üniversitesi

    Y.DOÇ.DR. A. GÜLÇİN KÜÇÜKKAYA