Mikrovida implant ankrajı kullanılan çekimli vakalarda anterior segmentin kütlesel (en masse) retraksiyonu ile iki aşamalı retraksiyonunun karşılaştırılmalı olarak incelenmesi
Analysis of en-masse retraction compared with two-step retraction of the anterior segment using microscrew implant anchorage in extraction cases
- Tez No: 230068
- Danışmanlar: DOÇ. DR. AYÇA ARMAN ÖZÇIRPICI
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: Dental implantasyon, Dental implantlar, Dişler, Köpek dişleri, Ortodonti, Ortodontik aygıtlar, Ortodontik teller, Prospektif çalışmalar, Dental implantation, Dental implants, Teeth, Cuspid, Orthodontics, Orthodontic appliances, Orthodontic wires, Prospective studies
- Yıl: 2009
- Dil: Türkçe
- Üniversite: Başkent Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Ortodonti Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Bu randomize prospektif klinik çalışmanın amacı, mutlak ankraj kontrolünü sağlamak amacıyla mikrovida implant ankrajı kullanılan çekimli vakalarda üst çenede anterior dişlerin kütlesel (en masse) retraksiyonu ile 2 aşamalı keser retraksiyonunun etkilerini incelemektir.Bu amaçla çekim boşluklarının maksimum ankrajla kapatılması gereken 16 hastaya sağ ve sol 1. molarlar ile 2. premolarlar arasına bukkal tarafa 1,2 mm çap ve 8 mm uzunlukta mikrovida implantlar iskeletsel ankraj amacıyla yerleştirilmiştir. Hastalar 8'er bireyden oluşan 2 gruba rastgele dağıtılmıştır. Birinci gruptaki bireylerde (18,5 ortalama yaşa sahip 6 bayan, 2 erkek) anterior segmentin retraksiyonu tek aşamada kütlesel (en masse) olarak gerçekleştirilmiştir. İkinci gruptaki bireylerde (19,7 ortalama yaşa sahip 6 bayan, 2 erkek) önce kanin dişler mikrovidalarla, sonra keser dişler bull-looplu arklarla retrakte edilmiştir. Tüm bireylerden retraksiyon başı (T1) ve retraksiyon sonunda (T2) lateral sefalometrik filmler ve alçı modeller elde edilmiştir. Yapılan ölçümler istatistiksel olarak Bağımlı t-testi, Wilcoxon testi, Student's t-testi ve Mann Whitney U testi ile değerlendirilmiştir.Mikrovida ankrajı kullanılarak kütlesel retraksiyon grubunda ortalama 7,3 ayda, iki aşamalı retraksiyon grubunda ortalama 8,1 ayda hastaların çekim boşlukları ankraj kaybı olmadan başarılı bir şekilde kapatılmıştır. Uygulanan toplam 32 mikrovidanın tamamı (%100) retraksiyon bitimine kadar yerlerinde stabil kalmıştır. Tedavi süresi bakımından gruplar arasında anlamlı fark bulunamamış ancak retraksiyon hızı 1. grupta (0,74 mm/ay), 2. gruba göre (0,57 mm/ay) daha fazla olmuştur. Birinci grupta üst keserlerde 5,25 mm retraksiyon, 3,63° devrilme ve 0,81 mm intrüzyon hareketi görülmüştür. İkinci grupta üst keserlerde 4,63 mm retraksiyon ile 7,13° devrilme hareketi olmuş, intrüzyon hareketi meydana gelmemiştir. Sadece üst keserlerin devrilme hareketindeki farklılık gruplar arasında anlamlıdır (p<0,05). Buna bağlı olarak birinci grupta A noktasının 0,88 mm geriye hareketi meydana gelmiştir (p<0,05). Öte yandan, ikinci grupta mandibuler düzlem açısında 0,88° azalma anlamlı bulunmuştur (p<0,001). Birinci grupta üst molarlarda anlamlı bir hareket gözlenmemiş, ankraj başarıyla korunmuştur. İkinci grupta üst molarlarda 0,63 mm distale devrilme görülmüş, bu hareket istatistiksel olarak anlamlı bulunmuştur (p<0,001). Her iki grupta da alt ve üst dudaklarda yaklaşık 2 mm retrüzyon meydana gelmiştir. Model ölçümlerine göre interkanin mesafe 1. grupta 2,38 mm (p<0,001), 2. grupta 2,75 mm azalmış (p<0,01), intermolar mesafe her iki grupta da değişmemiştir.Mikrovida ankrajı kullanılarak üst çenede gerçekleştirilen anterior segmentin kütlesel retraksiyonu daha hızlı diş hareketi sağlamış, elde edilen keser hareketi paralele yakın olmuş, molar ankrajı başarıyla korunmuş ve A noktasının daha fazla geriye hareketi gerçekleşmiştir. Öte yandan iki aşamalı retraksiyon işleminde keserler daha fazla devrilmiş, üst molarlarda distale devrilme görülmüş, alt ön yüz yüksekliğinde azalma meydana gelmiştir.
Özet (Çeviri)
The purpose of this randomized prospective clinical study was to investigate the treatment effects of en-masse retraction compared with two-step retraction of maxillary anterior teeth with microscrews as absolute anchorage units in patients undergoing extraction of first premolars.Sixteen subjects requiring high anchorage for space closure were included in the study and microscrew implants measuring 1,2 mm in diameter and 8 mm in length were placed between right and left first molars and second premolars buccaly to provide skeletal anchorage. The patients were randomly divided into two groups each consisting of 8 patients. In the first group (6 women, 2 men, mean age 18,5), space closure was achieved by en-masse retraction of maxillary anterior teeth. In the second group (6 women, 2 men, mean age 19,7), the retraction procedure was performed in two steps: canine retraction with microscrews followed by incisor retraction with bull-loops. Lateral cephalograms and cast models were taken from each patient before retraction (T1) and after space closure (T2). Independent t-test, Wilcoxon test, Student?s t test and Mann Whitney U test were used for statistical analysis.Successful closure of the extraction spaces without any anchorage loss was achieved with microscrews in 7,3 months for the en-masse retraction group and in 8,1 months for the two-step retraction group. All 32 microscrews (100%) remained stable until the end of the retraction period. Even though there was no significant difference in treatment times, the first group showed greater incisor retraction rate (0,74 mm per month) than the second group (0,57 mm per month). 5,25 mm retraction, 3,63° tipping and 0,81 mm intrusion of the central incisors were observed in the first group. The central incisors of the second group showed 4,63 mm retraction and 7,13° tipping and no intrusion. Only the difference in tipping movement of the incisors was statistically significant between two groups (p<0,05). Therefore, 0,88 mm significant retrusion of A- point was seen in the first group (p<0,05). On the other hand, 0,88° significant decrease in mandibular plane was found in the second group (p<0,001). No significant maxillary first molar movement was noted in the first group thus no anchorage loss occurred. The first molars in the second group showed 0,63 mm distal tipping which was considered significant (p<0,001). Both groups showed approximately 2 mm of upper and lower lip retrusion. Cast model measurements proved 2,38 mm decrease of intercanine distance in the first group (p<0,001), 2,75 mm decrease in the second group (p<0,01), no change of intermolar distance in both groups.En-masse retraction of the upper anterior teeth with microscrew implants showed faster rate of tooth movement, more translational incisor retraction, no molar movement and reduction of A-point. On the other hand, two-step retraction of upper anterior teeth showed more tipping of the incisors, distal tipping of upper molars and reduction of mandibular plane angle.
Benzer Tezler
- Farklı implant - abutment bağlantı tiplerinde çiğneme simülatörü ile yaşlandırma öncesi ve sonrası oluşan mikro boşluğun 3 boyutlu mikro bilgisayarlı tomografi ile in vitro olarak değerlendirilmesi
In vitro evaluation of microgap by micro - computed tomography in different implant – abutment connection types before and after aging with mastication simulator
ASİLKAN GEZ
Doktora
Türkçe
2021
Diş HekimliğiAnkara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. PELİN ÖZKAN
- Sürtünmesel kilitlenen implant-dayanak bağlantısının yüzey elementel analizinin (EDX) ve pürüzlülüğünün, mikro boşluk ve dayanak yer değiştirme miktarının in-vitro incelenmesi
In-vitro evaluation of surface elemental analysis (EDX) and roughness,amount of micro-gaps and abutment displacement of frictional lockingtaper implant-abutment connection
MUSTAFA BURAK TANGÜL
Doktora
Türkçe
2021
Diş HekimliğiEge ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. BÜLENT GÖKÇE
- İmplant-abutment aralığının farklı yükler altında micro-ct'de incelenmesi
Evaluation of implant-abutment interface using micro-ct under different loading
CEREN BAYRAKTAR
Diş Hekimliği Uzmanlık
Türkçe
2022
Diş HekimliğiEge ÜniversitesiPeriodontoloji Ana Bilim Dalı
PROF. DR. GÜLNUR EMİNGİL
- Vidalı implant üstü sabit restorasyonlarda protetik komponent tercihinin ve implant açılanmalarının protetik vida üzerindeki mekanik etkisi
The mechanical effect of different implant angles and prosthetic component preference on implant supported screw retained prosthetis's screw
KÜBRA NUR DURAN İLHAN
Doktora
Türkçe
2025
Diş Hekimliğiİstanbul Medipol ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. GÜLSÜM SAYIN ÖZEL
- Farklı implant- abutment bağlantılarının çiğneme kuvvetleri altında yorgunluk, kırılganlık dayanımlarının in-vitro olarak incelenmesi
The in-vitro comparison of fracture resistance in dental implant-abutment connection using two different implant systems besides chewing forces
SELİN KIPIRDI
Doktora
Türkçe
2013
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. BİLGE GÖKÇEN RÖHLİG