Diagnostik radyolojide bazı parametrelerin ölçülmesinde kullanılacak bir düzeneğin yapımı

The Construction of a system for the measurement of some parameters used diagnostic radiology

  1. Tez No: 23000
  2. Yazar: DİLEK HASANÇEBİ
  3. Danışmanlar: PROF. DR. NURAY BÜGET
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Radiology and Nuclear Medicine
  6. Anahtar Kelimeler: Diagnostik (Radyolojide Kalite Kontrolü, Radyografik X- Işın Sistemleri için Kalite Temini, Tıb£i Fizik, Tıbbi Görüntüleme Fiziği, Kalite kontrol, Teşhis-görüntüleme, Tıbbi fizik, X ışını, Quality Control In Diagnostic Radiology, Quality Assurance For Radiographic X- Ray Units, Medical Physics, The Physics Of Medical Imaging, Quality control, Diagnostic imaging, X ray
  7. Yıl: 1992
  8. Dil: Türkçe
  9. Üniversite: Ankara Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Yüksek Lisans Tezi DİAGNOSTÎK RADYOLOJİDE BAZI PARAMETRELERİN ÖLÇÜLMESİNDE KULLANILACAK BİR DÜZENEĞİN YAPIMI Dilek HASANÇEBİ Ankara Üniversitesi Fen Bilimleri Enstitüsü Fizik Mühendisliği Anabilim Dalı Danışman : Prof. Dr. Nuray BÜĞET 1992, 88 Jüri : Prof. Dr. Nuray BÜĞET Prof. Dr. Hikmet BAYHAN Prof. Dr. Sedat IŞIK Bu çalışmada, konvansiyonel x- ışını sistemlerinde görüntü kalitesini ve ışınlama dozunu etkileyen bazı parametrelerin rutin ölçümleri için basit ve ucuz bir test cihazı yapıldı. iki kısımdan oluşan çalışmanın ilk aşamasında, tüp voltajını (kVp), ışınlama zamanını ve demetin dikliğini test etmek için sırasıyla bakır bir basamak, dönen bir disk ve plexiglas bir silindir yapıldı ve kVp kalibrasyon eğrisi elde edildi. ikinci kısımda ise demetin tekraredilebilirlik ve lineerite ölçümleri, filmin banyo işleminin kalite kontrolü ve karakteristik H.D. eğrisinin çizimi, yapılan alimunyum bir basamak ve üzerinde eşit aralıklı kurşun şeritler bulunan plexiglasbir filtre ile gerçekleştirildi. Sonuçlar, standart sistemlerden elde edilen değerlerle karşılaştırıldı ve test cihazının güvenilirliği sağlandı.

Özet (Çeviri)

ABSTRACT Masters Thesis THE CONSTRUCTION OF A SYSTEM FOR THE MEASUREMENT OF SOME PARAMETERS USED DIAGNOSTIC RADIOLOGY Dilek HASANÇEBİ Ankara University Graduate School of Natural and Applied Science Department of Physics Engineering Supervisor : Prof. Dr. Nuray BÜĞET 1992, 88 Jury : Prof. Dr. Nuray BÜĞET Prof. Dr. Hikmet BAYHAN Prof. Dr. Sedat IŞIK In this work a simple and cheap test equipment has been constructed for the routin measurements of some parameters affecting the image quality and the exposure dose in the conventional x- ray systems. In the first stage of the work consisting of two parts the constructions of a copper step-wedge a rotating discand a plexiglass cylinder have been made to test the tube voltage (kVp) the exposure time and the perpendicularity of the beam respectively and the kVp calibration curve has been obtained, In the second part, the measurements of reproducability and the linearity of the beam, the quality control of the film??<-:? t t, [processing and the plot of the characteristic H.D.- curve have been made by constructing an aliminum stepwedge together with a plexiglass filter having equally spaced lead strips. The results have been compared with the values obtained by standart systems and the veliability of the systems has been established.

Benzer Tezler

  1. Fantom modellerde 50-120 KV için effektif doz hesabı

    Başlık çevirisi yok

    GEİATH BREİKİ

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    Fizik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. ADNAN TAYMAZ

  2. Kronik kalp yetmezliği belirtileri gösteren köpeklerde klinik biyokimyasal radyografik elektrokardiyografik ve ultrasonografik bulgular ve sağaltım

    Clinical, biochemical, radiologic, electrocardiographic and ultrasonographic findings and therapy in dogs exhibiting chronic heart failure

    RAMAZAN DURGUT

    Doktora

    Türkçe

    Türkçe

    1999

    KardiyolojiAnkara Üniversitesi

    İç Hastalıkları Ana Bilim Dalı

    PROF. DR. ARİF KURTDERE

  3. Radiküler kist ve granülomların dijital histogram analizi ile ayırdedilmesi

    Differention of radicular cyst and granulomas with digital histogram analysis

    ÜLKEM AYDIN

    Doktora

    Türkçe

    Türkçe

    1998

    Diş HekimliğiGazi Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF. DR. TAYFUN ALAÇAM

  4. Arayüz çürüklerinin radyografik olarak saptanmasında görüntü kalitesinin etkisi

    Başlık çevirisi yok

    NESRİN ERGÜL

    Doktora

    Türkçe

    Türkçe

    1996

    Diş HekimliğiEge Üniversitesi

    Oral Diagnoz ve Radyoloji Ana Bilim Dalı

    PROF.DR. TANER OKŞAN

  5. Konya yöresindeki buzağılarda şekillenen bazı metabolik kemik hastalıklarının teşhisinde biyokimyasal ve radyolojik kriterlerin önemi

    The Importance of biochemical and radiological findings in the diagnosis of metabolic bone diseases in calves of Konya region

    MUSTAFA KUL

    Doktora

    Türkçe

    Türkçe

    1996

    Veteriner HekimliğiSelçuk Üniversitesi

    Veterinerlik Cerrahisi Ana Bilim Dalı

    PROF.DR. NURİ YAVRU