Pb(II)-seçici PVC elektrot hazırlanması ve analitik uygulamaları
Preparation of lead (II)-selective PVC electrode and their analytical application
- Tez No: 213803
- Danışmanlar: YRD. DOÇ. DR. ESİN CANEL
- Tez Türü: Yüksek Lisans
- Konular: Kimya, Chemistry
- Anahtar Kelimeler: Potansiyometri, iyon-seçici elektrotlar, kaliks[4]aren, kurşun(II) iyonu, İyon seçici elektrotlar, Potentiometry, ion-selective electrodes, calix[4]arene, lead (II) ion, Ion selective electrodes
- Yıl: 2007
- Dil: Türkçe
- Üniversite: Ankara Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Kimya Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Yeni sentezlenen kaliks[4]aren bileşikleri 5,11,17,23-Tetra-ter-bütil?25,27-bis(benzilaminokarbonilmetoksi)-26,28-dihidroksikaliks[4]aren (I), 1,3-[etilen-bis-(aminokarbonilmetoksi)]-p-ter-bütilkaliks[4]aren (II) ve 25,27-bis-(4-nitrobenziloksi)-26,28-dihidroksikaliks[4]aren (III) bazlı yeni kurşun iyon-seçici PVC membran elektrotlar geliştirildi. En iyi performans iyonofor I bazlı elektrotla elde edildi. Bu elektrot, Pb(II) iyonları için 26,51±2,19 mV/p[Pb] eğimle, geniş bir konsantrasyon aralığında (1,0×10?2?1,0×10?6 M) Nernstian bir cevap gösterdi. Elektrot oldukça hızlı cevap süresine sahipti (~10,0 s) ve en az 35 gün kullanılabildi. Önerilen elektrotlar bazı metal katyonları varlığında Pb(II) iyonlarına iyi bir seçicilik gösterdi ve pH 4?5 aralığında kullanılabildiler. Elektrotlar, kurşun iyonlarının EDTA ile potansiyometrik titrasyonunda indikatör elektrot olarak kullanıldı ve Sn ve Sb içeren standart referans maddedeki kurşun içeriği başarılı bir şekilde tayin edildi.
Özet (Çeviri)
New PVC membrane electrodes for Pb (II) ion based on a recently synthesized calix[4]arene compound of 5,11,17,23-Tetra-tert-butyl?25,27-bis(benzylaminocarbonylmethoxy)-26,28-dihydroxycalix[4]arene(I), 1,3-[ethylene-bis-(aminocarbonylmethoxy)]-p-tert-butylcalix[4]arene(II) and 25,27-bis-(4-nitrobenzyloxy)-26,28-dihydroxycalix[4]arene(III) were developed. The best performance was obtained with the electrode based on ionophore I. The electrode exhibits a Nernstian response for Pb(II) ions over a wide concentration range (1,0×10?2?1,0×10?6 M) with a slope of 26,51±2,19 mV/p[Pb]. The response time of the electrode was relatively fast (~10 s) and this electrode could be used for at least 35 days. The proposed electrodes show good selectivity for lead(II) ions in presence of some metal cations and could be used in the pH range of 4?5. The electrodes were successfully applied as an indicator electrode for the potentiometric titration of lead ions with EDTA and to determine lead content in standard referans material containing Sb and Sn.
Benzer Tezler
- Oksimler kullanılarak iyon seçici elektrot hazırlanması
Preparation of ion-selective electrode by using oximes
TUĞBA SARDOHAN KÖSEOĞLU
- Kaliksarenler kullanılarak iyon-seçici elektrot hazırlanması
Preparation of ion-selective electrode by using calix[4]arene
SİBEL EROL
- Bilgisayar yardımıyla soğutucu akışkan özelliklerinin hesaplanması ve termodinamik tablo ve diyagramlarının hazırlanması
Computer aided calculation of thermodynamic properties and formation of tables and diagrams of refrigerants
YAHYA DOĞU
- İç dolgu çözeltisiz Pb(II)-seçici elektrot hazırlanması
Preparation of lead (II)-selective electrode without internal filling solution
ELİF TUNA
- Biosorption sites for lead [Pb(II)] in Phanerochaete chrysosporium
Phanerochaete chrysosporium`da kurşun [Pb(II)] için biyosorpsiyon bölgeleri
LEVEND KAYA
Yüksek Lisans
İngilizce
2004
BiyolojiOrta Doğu Teknik ÜniversitesiBiyoloji Ana Bilim Dalı
PROF.DR. FERİDE SEVERCAN
PROF.DR. GÜLAY ÖZCENGİZ