Klinik lineer hızlandırıcıların su fantomundaki doz dağılımlarının Monte Carlo Yöntemi ile elde edilmesi
Determination of dose distributions for clinical linear accelerators using Monte Carlo Method in water phantom
- Tez No: 202352
- Danışmanlar: PROF. DR. AHMET CENGİZ
- Tez Türü: Yüksek Lisans
- Konular: Fizik ve Fizik Mühendisliği, Onkoloji, Biyofizik, Physics and Physics Engineering, Oncology, Biophysics
- Anahtar Kelimeler: Monte Carlo Simülasyonu, lineer hızlandırıcılar, yüzde derin doz, doz profili, radyoterapi, Doz dağılımı, Monte Carlo benzetimi, Monte Carlo simulation, linear accelerator, percentage depth dose, dose profile, radiotherapy, Dose distribution
- Yıl: 2007
- Dil: Türkçe
- Üniversite: Uludağ Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Fizik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
Radyasyon terapisinde Monte Carlo hesaplamaları için çeşitli kodlar kullanılmaktadır. Bu çalışmada, sudaki doz dağılımlarında Siemens PRIMUS klinik lineer hızlandırıcılardan (LINAC) fotonların fiziksel parametrelerinin etkileri için yeni bir Monte Carlo Simülasyon Programı (MCSP) geliştirilmiştir. MCSP, fotonların madde ile etkileşimleri dikkate alınarak yazılmıştır. Burada başlıca iki etkileşme dikkate alınmıştır: Compton (inkoherent) saçılması ve fotoelektrik olay. Bir nokta kaynaktan yayınlanarak su fantomu yüzeyine gelen fotonlar, bremsstrahlung ışınlarıdır. Foton takibinin yapılabilmesi için bu fotonların enerji dağılımlarının bilinmesi gerekir. Maksimum enerjisi 6 MeV (6 MV foton modu) olan bremsstrahlung fotonları dikkate alınmıştır. 6 MV foton modunda, yayınlanan fotonların enerjileri, Mohan tarafından deneysel olarak elde edilen spektrumdan örneklenmiştir (Mohan ve ark. 1985). MCSP'de doz profilleri ve yüzde derin doz eğrileri 107 parçacık takip edilerek hesaplanmıştır. Deneysel ölçümler, Siemens PRIMUS lineer hızlandırıcının 6 MV foton ışınları ve 48x48x48 cm3 boyutlu su fantomu kullanılarak yapılmıştır. 6 MV foton ışınları ile kaynak-fantom yüzeyi mesafesi, SSD=100 cm için yüzde derin dozlar, 3x3, 5x5, 10x10, 20x20 ve 30x30 cm2 alan boyutları için hem MCSP hem de yüksük iyonizasyon odası ile ölçülerek elde edilmiştir. 6 MV foton ışınları için doz profilleri, 3x3, 5x5, 10x10, 20x20 ve 30x30 cm2 alan boyutları ve beş farklı derinlik, 0, 3, 5, 10 ve 20 cm için hem MCSP hem de deneysel olarak elde edilmiştir. Simülasyonun doğruluğunu ve performansını incelemek için, ölçülen (deneysel) ve hesaplanan (MCSP) yüzde derin doz eğrileri ve doz profilleri karşılaştırılmıştır. Monte Carlo sonuçları, deneysel sonuçlarımız ile iyi bir uyum göstermektedir.
Özet (Çeviri)
Different codes were used for Monte Carlo calculations in radiation therapy. In this study, a new Monte Carlo Simulation Program (MCSP) was developed for the effects of the physical parameters of photons emitted from a Siemens PRİMUS clinical linear accelerator (LİNAC) on the dose distribution in water. For MCSP, it was written considering interactions of photons with matter. Here, it was taken into account mainly two interactions: The Compton (or incoherent) scattering and photoelectric effect. Photons which come to water phantom surface emitting from a point source were bremsstrahlung photons. It were ought to known the energy distributions of these photons for following photons. Bremsstrahlung photons which have 6 MeV (6 MV photon mode) maximum energies were taken into account. In the 6 MV photon mode, the energies of photons were sampled from using Mohan?s experimental energy spectrum (Mohan at al 1985). For MCSP, Dose (beam) profiles and Percentage Depth Dose (PDD) curves were calculated following simulating about 107 histories. The measurements were done using 6 MV photon beams of a Siemens PRİMUS linear accelerator and a 48x48x48 cm3 water phantom. Percentage depth doses for 6 MV photon beams were determined by both MCSP and measured with thimble ionization chamber for 3x3, 5x5, 10x10, 20x20 and 30x30 cm2 field sizes at SSD=100 cm. Dose profiles for 6 MV photons were determined at five different depths, 0, 3, 5, 10 and 20 cm for the reference field sizes of 3x3, 5x5, 10x10, 20x20 and 30x30 cm2 by both MCSP and measured. In order to investigate the performance and accuracy of the simulation, measured and calculated (MCSP) PDD curves and dose profiles were compared. The Monte Carlo results were shown good agreement with experimental measurements.
Benzer Tezler
- İki farklı lineer hızlandırıcıda (Saturne-42 ve oncor), elektron ışını tedavilerinde kullanılan, konüs ve trimmerin yüzey dozuna ve doz verimine etkilerinin karşılaştırılması
Comparison for the effect of a trimmer and a cone on surface dose and output factor of two different linear accelerators used in electron beam treatment (Saturne-42 ve oncor)
EVREN OZAN GÖKSEL
Yüksek Lisans
Türkçe
2008
Fizik ve Fizik Mühendisliğiİstanbul ÜniversitesiTemel Onkoloji Ana Bilim Dalı
PROF. DR. HATİCE BİLGE
- Yüksek enerjili x ışını ve elektron tedavilerinde nötron kontaminasyonu
Neutron contamination resulted from high energy x-ray and electron theraphy
İSMAİL HAKKI ARIKAN
Yüksek Lisans
Türkçe
1997
Radyoloji ve Nükleer TıpHacettepe ÜniversitesiRadyasyon Fiziği Uygulamaları Ana Bilim Dalı
PROF. DR. İ. LALE ATAHAN
- Yüksek enerjili foton hüzmeleriyle yapılan çeşitli klinik uygulamalar için yüzey dozlarının araştırılması
High energy photon beams skin dose analysis for various clinical set-ups
NADİR KÜÇÜK
Yüksek Lisans
Türkçe
2000
Onkolojiİstanbul ÜniversitesiTemel Onkoloji Ana Bilim Dalı
DOÇ. DR. GÖNÜL KEMİKLER
- Düzensiz (Korumalı) elektron alanlarında dozimetri
Dosimetry in the irregular (Shilded) fields of electrons
CEMİLE ÇELİK CEYLAN
Yüksek Lisans
Türkçe
2001
Fizik ve Fizik MühendisliğiAnkara ÜniversitesiFizik Mühendisliği Ana Bilim Dalı
PROF. DR. DOĞAN BOR
DOÇ. DR. BAHAR DİRİCAN