Fresenius-comtec cihazı ile yapılan çift doz trombosit toplama işleminin etkinliği
Efficacy of fresenius-comtec blood cell seperator in double dose platelet collection
- Tez No: 193778
- Danışmanlar: PROF. DR. ÖNDER ARSLAN
- Tez Türü: Yüksek Lisans
- Konular: Hematoloji, Hematology
- Anahtar Kelimeler: Hemaferez, çift doz trombosit, Fresenius-Comtec aferez cihazı, Hemapheresis, double dose platelet, Fresenius-Comtec apheresis device
- Yıl: 2006
- Dil: Türkçe
- Üniversite: Ankara Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: İç Hastalıkları Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZETFresenius-Comtec Cihazı ile Yapılan Çift Doz Trombosit Toplama şleminin EtkinliğiGünümüz tedavi protokollerinde kan komponentleri kullanımının oranının artmasıyla birlikteaferez cihazlarının teknolojileri de her geçen gün artmaktadır. Aferez cihazlarıyla hem düşüklökosit kontaminasyonlu hem de tek donörden fazla miktarda trombosit toplamakmümkündür. Aferez cihazlarıyla toplanan trombosit miktarını daha da arttırmak amacıylauygun bulunan donörlerden çift doz trombosit toplama uygulaması başlamıştır. Bu uygulamaile hem toplanan trombosit miktarının artması hem de maliyetin azalması söz konusudur. Buçalışmanın amacı; Fresenius-Comtec devamlı akım aferez cihazı kullanılarak çift doztrombosit toplama deneyimimizi aktarmaktır.3-Ocak-2006 ile 9-Haziran-2006 tarihleri arasında doktor muayenesinden geçen ve uygunbulunan 295 (294 erkek, 1 bayan) donöre çift doz trombosit toplama işlemi uygulandı. şlemöncesi trombosit sayısı â¥225x109/L ve â¥63 kg olan donörler Fresenius-Comtec cihazınayönlendirildi.Fresenius-Comtec cihazı ile 300 donöre işlem yapıldı. 5 donör reaksiyon nedeniyle işlemitamamlayamadı. Değerlendirilmeye alınan 295 donörden 209'u aferez ünitesinin belirlemişolduğu minimum 6.0x1011 trombosit seviyesine ulaşmıştır. Elde edilen başarı %72.3olmuştur. Avrupa kalite kontrol standardına göre üründeki lökosit kontaminasyonunun<1x106 olması gerekmektedir. Çalışmamızda akım sitometri kullanılarak rastgele seçilen 38üründe ortalama 0.224x106 lökosit kontaminasyonu belirlendi.Kan merkezlerinde uygun donörlerden çift doz trombosit toplanarak hem donör ihtiyacınıazaltmak hem de maliyeti düşürmek mümkün olabilir.
Özet (Çeviri)
SUMMARYEfficacy of Fresenius-Comtec Blood Cell Seperator in Double Dose Platelet CollectionWith the raise of using blood components in recent treatment procedures the technology ofapheresis devices are also developing. Due to increase the number of platelet collecting byapheresis devices, blood banks began to collect double dose platelets from suitable donors. Bythis application we can increase the collected platelets while decreasing the costs. The aim ofthis study was to document our double dose platelet collection experience by using Fresenius-Comtec continious flow apheresis device.Between 3-January-2006 and 9-June-2006 double dose platelet collection was performed on295 suitable donörs (294 men, 1 woman) after medical examination. Donors with a plateletprecount of â¥225x109/L and â¥63 kg were directed to Fresenius-Comtec apheresis device fordouble dose collection.300 procedures were performed with Fresenius-Comtec apheresis device. Because of donorreaction 5 of them can not complete the procedure. 209 of 295 donors that taken intoevaluation have reached to the minimum platelet level of 6.0x1011. We obtained 72.3%success. According to the European Quality Control Criteria, leucocyte count in the productshould be <1x106. In our study, average 0.224x106 leucocyte contamination was determinedin randomly selected 38 products by using flow cytometry.In our opinion; It can be possible to decrease both the cost and donor requirement forplateletpheresis by collecting double dose platelet collection from suitable donors in bloodbanks.
Benzer Tezler
- Fresenius comtec aferez cihazları ile uygun donörlerden çift doz trombosit süspansiyonu elde edilmesinin değerlendirilmesi
Evaluation of the resenius comtec blood cell seperator in the collection of double dose apheresis platelets from suitable donors
CENK ÇETİN
Yüksek Lisans
Türkçe
2004
HematolojiAnkara Üniversitesiİç Hastalıkları Ana Bilim Dalı
PROF. DR. HAMDİ AKAN
- Aspergillus fumigatus Fresenius'un PCR ile DNA düzeyinde tanısının standardizasyonu
Standardization of identification of Aspergillus fumigatus Fresenius based on DNA by PCR
ÖZGÜR DEMİR
Yüksek Lisans
Türkçe
2004
BiyolojiEge ÜniversitesiTemel ve Endüstriyel Mikrobiyoloji Ana Bilim Dalı
YRD. DOÇ. DR. ALEV HALİKİ
- Sağlıklı vericilerde çift doz trombosit aferezi işleminin trombosit fonksiyonları ve trombosit aktivasyonu üzerine etkisi
The effects of double dose plateletpheresis on platelet functions and platelet activation in healthy apheresis donors
FERAHNAZ GENÇAY YILMAZ
Yüksek Lisans
Türkçe
2004
HematolojiAkdeniz Üniversitesiİç Hastalıkları Ana Bilim Dalı
DOÇ. DR. İHSAN KARADOĞAN
- Allojenik granülosit ve kök hücre donörlerinde rHuG-CSF'in nötrofil adezyon molekül ekspresyonu ve trombosit-lökosit kompleks oluşumu üzerine etkisi
Effect of G-CSF administration to allogeneic stem cell and granulocyte donors on platelet-leukocyte complex formation anf neutrophil adhesion molecule expression
CAVİDAN KARADOĞAN
Yüksek Lisans
Türkçe
2002
HematolojiAkdeniz Üniversitesiİç Hastalıkları Ana Bilim Dalı
PROF.DR. LEVENT ÜNDAR
- Farklı ticari propofol preparatlarının klinik etkinliklerinin karşılaştırılması
Comparative assesment of clinical efficacy of commercial propofol preparations
GÖKŞEN ÖZ
Tıpta Uzmanlık
Türkçe
2005
Anestezi ve ReanimasyonHacettepe ÜniversitesiAnesteziyoloji ve Reanimasyon Ana Bilim Dalı
DOÇ. DR. DİDEM DAL