Bir el bileği modüler yüzey replasman protezinin sonlu elemanlar analizi yöntemiyle biyomekanik değerlendirmesi
Biomechanical evaluation of a modular surface replacement wrist prothesis with finite element analysis.
- Tez No: 192522
- Danışmanlar: DOÇ.DR. AHMET EGE
- Tez Türü: Tıpta Uzmanlık
- Konular: Ortopedi ve Travmatoloji, Orthopedics and Traumatology
- Anahtar Kelimeler: Elbileği potezi, elbileği biyomekaniği, sonluelemanlar analizi, wrist arthroplasty, biomechanics of the wrist, finiteelement analysis
- Yıl: 2006
- Dil: Türkçe
- Üniversite: Zonguldak Karaelmas Üniversitesi
- Enstitü: Tıp Fakültesi
- Ana Bilim Dalı: Ortopedi ve Travmatoloji Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZETDemirel, N., Bir el bileği modüler yüzey replasman protezininsonlu elemanlar analizi yöntemi ile biyomekanik değerlendirmesi,Zonguldak Karaelmas üniversitesi Tıp Fakültesi, Ortopedi veTravmatoloji Tezi. Zonguldak, 2006El bileği eklemi kompleks yapıya sahip olan bir eklemdir. Distal radiuselbileği eklemini oluşturan elemanlardan birisidir. Burada tanımlananyaklaşım travma, tümör, romatizmal veya dejeneratif hastalıklara sekonderolarak eklemin diğer kompartmanlarını tutmadan distal radius eklem yüzünütutan durumlarda yapılan sınırlı bir replasman girişimidir. Yapılan bureplasmanla sadece bozuk olan distal radius eklem yüzeyinin anatomiközelliklere ve dolayısıyla biyomekaniğe sadık kalarak sentetik materyalledeğiştirilmesi sağlanmaktadır.Bu çalışmada distal radius eklem yüzeyini ilgilendiren patolojilerdekullanılmak üzere tasarlanmış olan modüler parsiyel yüzey replasmanprotezinin biyomekanik değerlendirmesi ?sonlu elemanlar analizi yöntemi?kullanılarak yapılmıştır. Yapılan bu analizde protezin üç ana parçasınınbirbirine tespitini sağlayan vidanın minimum ve maksimum sıkılma momentive ele uygulanan yükün protezin artiküler yüzeyine yansıtılması sonucunda herüç ana parçadaki kuvvet yığılımları hesaplanmıştır.Vida hesabından çıkan sonuçlara göre vida minimum 35 daNmm vemaksimum 160.95 daNmm a kadar sıkılmalıdır. Bu değerlerin arasındauygulanan sıkma momenti ile protezin daha stabil olacağı, bu aralıklarındışında sıkılması durumunda ise vida ve parçaların yivlerinde aşınma vestabilite kaybı meydana geleceği ortaya konulmuştur.Protez yüzeyine uygulanan yük sonucunda protezin artiküler vemetafizer bölgesi arasında yer alan boyun bölgesinin maruz kaldığı kuvvetyığılımı 5,94 ile 9,9 arasında değişmektedir. Elde edilen değerlerle bubölgenin yüksek yığılımlara maruz kaldığı ve bu iki parçanın gevşemeyönünden diğer alanlara oranla daha riskli olduğu düşünülmektedir. Artiküleryüzeyde meydana gelen yığılmalar ise özellikle skafoid bölgede daha fazlaolmak üzere 2,64 ile 3,3 arasında değişmektedir. Bu sonuç ise bu alanın çokdüşük yığılıma maruz kaldığını ve skafoid fossanın da lunat fossaya göredaha fazla yığılıma uğradığını göstermektedir. Protezin metafizer ve diafizerbölgelerinde ortaya çıkan kuvvet yığılımlarının oldukça düşük olan 0 ile 1,32değerleri arasında olması protezden distal radiusa transfer olan kuvvetyığılımının da oldukça düşük olacağına işaret etmektedir. Bu durum distalradiusda meydana gelebilecek olası stres kırıklarının oranının da düşükolacağı anlamına gelmektedir.
Özet (Çeviri)
ABSTRACTDemirel,N., Biomechanical evaluation of a modular surfacereplacement wrist prosthesis with finite element analysis, ZonguldakKaraelmas university Faculty of Medicine, Thesis in Orthopaedics andTaumatology. Zonguldak, 2006The wrist joint is an articulation with complex structure. Distalradius is one of the elements that from the wrist. The approach described hereis a limited replacement intervention for the conditions that do not affectcompartments outside distal radius articulation, occuring as a secondary resultsof trauma, tumor, rheumatoid arthritis and degenerative diseases.By this replacement approach, a synthetic replacement of thedefective distal radius is ensured in a way complying with the anatomicfeatures and biomechanics.At this study, the biomechanical evaluation of the modular, partialsurface replacement prosthesis, destined to use at pathologies affecting thesurface of the distal radius articulation was made by using the ?finite elementanalysis methot?. At this analysis, the force accumulations at each of the threemain parts as a result of the minimum and maximum squeezing moment of thescrew that connects the three main parts of the prosthesis and transfer of theload applied to the hand on the articular surface of the prosthesis werecalculated.According to the results of the screw calculation, the screw must besqueezed at minimum 35 daNmm and at maximum 160.95 daNmm. It wasdetermined that the prosthesis might be more stable by the squeezing momentapplied within these values and if the screw is squeezed outside this interval,the screw and grooves of the parts may be worn and stability loss may occur.As a result of the load applied on the prosthesis surface, the force thatthe neck section between the articular and metaphisial region of the prosthesischanges between 5.94 and 9.9. It is considered that this section faces highforce accumulations and these two parts face higher risk of slackening whencompared to other regions.The accumulations occuring at the articular surface changes between2.64 and 3.3, higher especially at the scaphoid region. This result indicates thatthis region faces less force accumulation and the scaphoid fossa faces moreaccumulation than lunat fossa. The fact that the force accumulations at themetaphiser and diaphiser regions of the prosthesis are between 0 and 1.32,which is very low shaows that the force accumulation transferred from theprosthesis to distal radius is very low. This stuation means that potential stresfractures that may occur at distal radius will be low
Benzer Tezler
- A research on intelligent software development for design and analysis of factorial experiments
Başlık çevirisi yok
İNCİ BATMAZ DANACI
Doktora
İngilizce
1993
Bilgisayar Mühendisliği Bilimleri-Bilgisayar ve KontrolEge ÜniversitesiBilgisayar Mühendisliği Ana Bilim Dalı
PROF. DR. AYDIN ÖZTÜRK
- Çeşitli büyüklüklerdeki alışveriş mekanlarını aydınlatma sistemleri tasarım ilkeleri
Designing principles of lighting systems in store designs of various types
HALE İKİZLER
Yüksek Lisans
Türkçe
1996
Mimarlıkİstanbul Teknik ÜniversitesiMimarlık Ana Bilim Dalı
PROF. DR. MEHMET Ş. KÜÇÜKDOĞU
- Development of an expert system for wire electrical discharge machining
Tel elektro-erozyon işleme için bir uzman (eksper) sisteminin geliştirilmesi
SERKAN ÇETİN
Yüksek Lisans
İngilizce
2000
Makine MühendisliğiOrta Doğu Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. M. A. ŞAKİR ARIKAN
- Çalışan evli kadınlarda üreme sağlığını koruyucu davranışların geliştirilmesi
Promoting reproductive health preventive behaviours in married women workers
HÜLYA DEMİRCİ
Yüksek Lisans
Türkçe
2004
Hemşirelikİstanbul ÜniversitesiHemşirelik Ana Bilim Dalı
PROF.DR. HACER KARANİSOĞLU