Bazı biyolojik dokuların lineer x-ışını azaltma katsayılarının tayini ve bu katsayıların bilgisayarlı tomografide doku ayırımının iyileştirilmesi için kullanılması
Determination of linear x-ray attenuation coefficients of some biological tissues and use of these coefficients in tissue contrast enhancement in computed tomography
- Tez No: 185480
- Danışmanlar: PROF.DR. SALİH ZEKİ ERZENEOĞLU
- Tez Türü: Doktora
- Konular: Fizik ve Fizik Mühendisliği, Patoloji, Radyoloji ve Nükleer Tıp, Physics and Physics Engineering, Pathology, Radiology and Nuclear Medicine
- Anahtar Kelimeler: X-ışını tüpü, X-ışını azaltma katsayısı, bilgisayarlı tomografi, X-ışını filtreleri.i, X-ray tube, X-ray attenuation coefficient, computed tomography, X-rayfilters.ii
- Yıl: 2006
- Dil: Türkçe
- Üniversite: Atatürk Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Fizik Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZETDoktora TeziBAZI BİYOLOJİK DOKULARIN LİNEER X-IŞINI AZALTMA KATSAYILARININTAYİNİ VE BU KATSAYILARIN BİLGİSAYARLI TOMOGRAFİDE DOKUAYIRIMININ İYİLEŞTİRİLMESİ İÇİN KULLANILMASIM. Erdem SAĞSÖZAtatürk ÜniversitesiFen Bilimleri EnstitüsüFizik Anabilim DalıDanışman: Prof. Dr. Salih Z. ERZENEOĞLUTemel bir parametre olarak biyolojik numunelerin X-ışını azaltma katsayısıspektroskopik, radyolojik ve patolojik değerlendirmelerde ve biyolojik dokulardaradyasyon dozu dağılımının belirlenmesinde oldukça yaygın olarak kullanılmaktadır.Özellikle belli biyolojik dokuların, temel kimyasında ve morfolojisinde meydana gelenanormalliklerin normal olanlardan ayırt edilmesine ve bu yolla teşhis edilmelerineimkan sağlamaktadır. Bu tez çalışması ile inceliklerini keşfetme imkanı bulduğumuz BT(Bilgisayarlı Tomografi) sistemlerinin ve bu sistemlerde elde edilen X-ışını azaltmakatsayılarının yüksek doğrulukla belirlenmesinin önemi ortaya konmuştur.BT sistemi ile elde edilen verilerde, azalan filtrelenmiş ortalama foton enerjine bağlıolarak X-ışını azaltma katsayıları ve dolayısıyla suyun azaltma katsayısına oranıgösteren HU (Hounsfield Unit) değerleri artmaktadır. EDXRF (Energy Dispersive X-Ray Fluorescence) ölçümlerinin nispeten uzun sürelerde gerçekleştirilebilmesi buölçümleri güvenilir kılmaktadır. Önerilen filtrelerle, ancak kalibre edilemeyen tıbbiteşhis amaçlı BT cihazlarında elde edilen, canlıdan çıkarılmış beyin tümörü kesitlerinde,beklendiği üzere görüntülerdeki doku kontrastının arttığı gözlenmiştir.2006, 66 sayfa
Özet (Çeviri)
ABSTRACTPhD ThesisDETERMINATION OF LINEAR X-RAY ATTENUATIONCOEFFICIENTS OF SOME BIOLOGICAL TISSUES AND USE OF THESECOEFFICIENTS IN TISSUE CONTRAST ENHANCEMENT IN COMPUTEDTOMOGRAPHYM. Erdem SAĞSÖZAtatürk UniversityInstitute of Natural and Applied SciencesDepartment of PhysicsSupervisor: Prof. Dr. Salih Z. ERZENEOĞLUAs an essential parameter, X-ray attenuation coefficient is being used in commonradiologic, pathologic and spectroscopic examinations and determination of radiationdose distribution in biological tissues. Especially, it enables us to diagnose bydifferentiating abnormal tissues from normal ones with their morphological and basicchemical structure. This thesis study demonstrates the importance of CT (ComputedTomography) systems and of precisely determining the X-ray attenuation coefficientswith these systems.For the data acquired from computed tomography systems with the decreasing filteredphoton mean energy, X-ray attenuation coefficients thus the HU (Hounsfield Unit)showing the ratio of these to water?s attenuation coefficient are increased. Parallel, X-ray attenuation measurements by EDXRF (Energy Dispersive X-Ray Fluorescence)methods are more reliable because of the length of acquisition times. With oursuggested X-ray filters, nevertheless without calibrated CT patient scanners for thesefilters, tissue contrast enhancement have been increased in ex vivo brain tumor slices.2006, 66 Pages
Benzer Tezler
- Mobil telefon kullanımına bağlı oluşan 900-1800 mhz radyo frekans dalgalarının meydana getirdiği elektromanyetik alanın iliak kanat kemik mineral yoğunluğuna etkisi
The effect of electromagnetic fields on bone mineral density of iliac bone produced by 900-1800 mhz radio frequency waves dependent on cellular phone usage
BEŞİR ANDAÇ AKSOY
Tıpta Uzmanlık
Türkçe
2006
Ortopedi ve TravmatolojiSüleyman Demirel ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF.DR. NEVRES HÜRRİYET AYDOĞAN
- In vivo indenter experiments on soft biological tissues for identification of material models and corresponding parameters
Mekanik malzeme modeli ve ilgili parametrelerin kestirilmesi için yumuşak biyolojik dokular üstünde yapılan yerinde indentör deneyleri
ALİ TOLGA PETEKKAYA
Yüksek Lisans
İngilizce
2008
Makine MühendisliğiOrta Doğu Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. ERGİN TÖNÜK
- Enerji iletim hatlarının oluşturduğu elektrik ve magnetik alanların canlılar üzerindeki etkileri
Effects of electrical and magnetic fields formed by energy transmission lines on living beings
SEVİL KOÇYİĞİT
Yüksek Lisans
Türkçe
2000
Elektrik ve Elektronik MühendisliğiMarmara ÜniversitesiElektrik Eğitimi Ana Bilim Dalı
YRD. DOÇ. DR. CANER AKÜNER
- Elektromagnetik alanın insanlar ve hayvanlar üzerindeki etkisinin incelenmesi ve alan hesapları
Study of effects electromagnetic field on the humans and animals, and calculating field
BAYRAM TÜRKOĞLU
Yüksek Lisans
Türkçe
1998
Elektrik ve Elektronik MühendisliğiYıldız Teknik ÜniversitesiElektrik Mühendisliği Ana Bilim Dalı
DOÇ. DR. NURETTİN UMURKAN
- Polimerik biyomalzemelerin biyouyumluluğu (deneysel çalışma)
Biocompatibility of polymeric biomaterials (experimental study)
FAİK TÜRKMEN
Tıpta Uzmanlık
Türkçe
2004
Ortopedi ve TravmatolojiSelçuk ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. UĞUR YENSEL