Geri Dön

Cep telefonu radyasyonunun farklı frekans-şiddetteki ses ile değişimi ve doku hidroksiprolin seviyesine etkisi

Variation in mobile phone radiation with voices of different frequencies and strengths, effects to tissue hydroxyproline level

  1. Tez No: 171480
  2. Yazar: ELÇİN ÖZGÜR
  3. Danışmanlar: Y.DOÇ.DR. GÖKNUR GÜLER
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyofizik, Biophysics
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2006
  8. Dil: Türkçe
  9. Üniversite: Gazi Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Biyofizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

160 6 ÖZET Günlük hayatımızda maruz kaldığımız cep telefonlarından yayılan RF radyasyonunun ses bağlı değişimi saptandı ve bu radyasyona farklı sürelerde maruz kalmanın kollagen sentezine etkisi üç farklı hidroksiprolin yöntemi kullanılarak araştırıldı. 1800 MHz frekans bandında çalışan Nokia 3210 marka ve modeldeki cep telefonu konuşma modülasyonunda iken ses verilmeyerek oluşan RF alan değeri ile farklı frekans ve şiddetlerde pure ton ses, kadın ve erkek sesi verilerek oluşan RF alan değeri değişimleri gözlendi ve bu değerler daha düşük SAR değerine sahip Nokia 2100 marka ve model cep telefonu kullanılarak oluşan alan değerleri ile karşılaştırıldı. Cep telefonu radyasyonunun sesin tipinden bağımsız, fakat sesin frekans ve şiddetine bağlı olarak değiştiği saptandı. Bu değişim teknolojileri farklı olan Nokia 3210 ve Nokia 2100 marka ve modelli iki telefon arasında farklılık gösterdi. Araştırma süresince anlık olarak ölçülen Nokia 3210 marka ve modeldeki cep telefonu konuşma modülasyonunda iken ses verilmeyerek oluşan RF alan 10 dakika ve 20 dakikalık periyotlarda 1 hafta süresince erkek kobaylara uygulandı ve kollagen sentezine etkisi karaciğer dokusunda 3 ayrı yöntem ile karşılaştırmalı olarak hidroksiprolin seviyesi belirlenerek saptandı. H. Stegemann-K. Stalder, I.S. Jamall, V.N. Finell ve TS ISO 3496 hidroksiprolin tayin yöntemleri ile karaciğer dokusu hidroksiprolin seviyesi tespit edildi. Uygulanan cep telefonu radyasyonunun karaciğer hidroksiprolin miktarında meydana getirdiği artışın istatistiksel olarak önemli olmadığı saptandı. Kullanılan üç yöntemden TS ISO 3496 Hidroksiprolin tayin yönteminin en hassas yöntem olduğu istatistiksel olarak da tespit edildi.

Özet (Çeviri)

161 7 SUMMARY Alteration of radiofrequency radiation emitted by mobile phones used in daily life due to sound was determined and effects of mobile phone exposure in different periods to collagen synthesis were investigated by using three different hydroxyproline level determination method. RF field value changes in speech modulation with no tone and pure tone, woman, man voice in different frequencies and strengths delivered to Nokia 3210 mobile phone operating in 1800 MHz frequency band were observed. These RF field changes were compared to RF radiation values for Nokia 2100 in the same condition. It was deduced that mobile phone radiation has the same alteration due to sound in different frequencies and strengths. However, the field difference in Nokia 3210 and Nokia 2100 radiated showed distinction because of having less SAR values. RF field of Nokia 3210 mobile phone in speech modulation of mute condition exposed to male guinea pigs for 10 and 20 minutes periods in 7 days of a week was measured instantaneously during the experiments and effects of this level of RF radiation to collagen synthesis determined by designation of hydroxyproline level in liver tissue. The hydroxyproline level designation methods of H. Stegemann-K. Stalder, I.S. Jamall, V.N. Finell and TS ISO 3496 were used in determining the level of hydroxyproline in liver tissue. It was detected that the increment found in hydroxyproline level due to mobile phone radiation in liver was statistically insignificant. It was detected statistically that the hydroxyproline level designation methods of TS ISO 3496 is most accurate way of determining hydroxyproline level in between the methods used in this research.

Benzer Tezler

  1. Cep telefonu radyasyonunun sıçan (Wistar albino) karaciğer dokusundaki oksidant/antioksidant dengesi üzerine etkisinin incelenmesi

    The Investigation of effects of mobile phone radiation on oxidant/antioxidant status of liver tissue Ifrom rat (Wistar albino)

    EMİNE OKCU YAYKAŞLI

    Yüksek Lisans

    Türkçe

    Türkçe

    2006

    BiyokimyaGazi Üniversitesi

    Kimya Ana Bilim Dalı

    PROF. DR. AHMET YAŞAR

  2. Cep telefonlarının yaydığı radyasyonun beyin üzerine etkilerinin elektron mikroskobik olarak değerlendirilmesi

    The electron microscopial evaluation of cell phone exposure on rat brain tissue

    GİYASETTİN DİKİCİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    BiyofizikDicle Üniversitesi

    Biyofizik Ana Bilim Dalı

    PROF.DR. SÜLEYMAN DAŞDAĞ

  3. Cep telefonlarının yaydığı radyasyonun testis üzerine etkilerinin elektron mikroskobik olarak değerlendirilmesi

    The electron microscopical evaluation of cell phone expasure on rat testes tissue

    ABDULLAH TOPRAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    BiyofizikDicle Üniversitesi

    Biyofizik Ana Bilim Dalı

    PROF.DR. SÜLEYMAN DAŞDAĞ

  4. Cep telefonlarının yaydığı radyasyonun böbrek üzerine etkilerinin elektron mikroskobik olarak değerlendirilmesi

    Elektron microscopial evaluation of cell phone exposure on rat kidneys

    MEHMET TEVFİK ADICAN

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    BiyofizikDicle Üniversitesi

    Biyofizik Ana Bilim Dalı

    DOÇ.DR. ABDURRAHMAN KAYA

  5. Cep telefonu mikrodalga radyasyonun farelerde folikül sayısı üzerine etkisi

    Başlık çevirisi yok

    HACER ÇELEBİ

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2003

    Kadın Hastalıkları ve DoğumYüzüncü Yıl Üniversitesi

    Kadın Hastalıkları ve Doğum Ana Bilim Dalı

    DOÇ. DR. ABDULAZİZ GÜL