Crown eter bileşiklerine dayalı katı-hal potansiyometrik iyon sensörleri

Solid-state potentiometric ion sensor base on crown-ether compounds

  1. Tez No: 171022
  2. Yazar: BARIŞ KEMER
  3. Danışmanlar: PROF.DR. MUSTAFA ÖZDEMİR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kimya, Chemistry
  6. Anahtar Kelimeler: İyon-Seçici Elektrot, Katı-Hal Elektrot, Crown-Eter, PVC-membran Elektrot. VI, Ion selective electrode, solid-state electrode, crown-ether, PVC-membrane electrode vn
  7. Yıl: 2005
  8. Dil: Türkçe
  9. Üniversite: Karadeniz Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET İyonofor 1; 4,4“-Bis[4”-fenoksi(15-crown-5)metil]benzil îyonofor 2; 23-(4'-Aminobenzo)-8,9:14,15-dibenzo-7,16-ditia-l,4-dioksa-10,13- diazasiklooktadekan gibi crown-eter bileşikleri (nötral iyonoforlar) kullanılarak tamamıyla katı-hal kontakt PVC-membran iyon-seçici elektrotlar hazırlandı. Elektrotların potansiyometrik performans karakteristikleri bilgisayarlı bir ölçüm sisteminde araştırıldı, îyonofor 1 ile hazırlanan elektrotun özellikle K+ iyonuna karşı oldukça seçici olduğu; iyonofor 2 ile hazırlanan elektrodun H+ iyonuna karşı yani pH sensör ve Fe3+ iyonuna karşı seçici olduğu sonucuna varıldı. İyonofor 1 ile hazırlanan elektrotların K+ çözeltisine karşı Nernst davranışı gösterirken (>55(±15) mV/her 10 kat değişim), cevap zamanlan kısa (<10 s) ve kullanım ömürleri uzundur (en az 1-2 ay). Tüm elektrotlar 1.10“2-1.10”5 moLL“1 konsantrasyon aralığında ana iyon çözeltisine karşı doğrusal davranış sergilemektedir. İyonofor 2 ile hazırlanan elektrot da ise her 10 birimlik konsantrasyon farkı içeren Fe3+ çözeltisi için oluşan potansiyel farkı (58±30) mV civarındadır. Cevap zamanları kısa (<15 s) ve kullanım ömürleri uzundur (en az 1-2 ay). Hazırlanan elektrotlar LIO^-LIO”5 moLL“1 konsantrasyon aralığında ana iyon çözeltisine karşı doğrusal davranış sergilemektedir. İyonofor 2 ile geliştirilen PVC-membran H+-seçici elektrot pH 2-11 arasında elektrot doğrusal bir davranış sergilerken, her bir pH farkı için oluşan potansiyel farkı (69+20) mv civarındadır. Cevap zamanları kısa (<10 s) ve kullanım ömürleri uzundur (en az 1-2 ay). Elektrotların ana iyon yaranda girişim yapan iyonlara karşı seçicilik katsayıları ”ayrı çözelti metodu" ile hesaplanmıştır.

Özet (Çeviri)

SUMMARY Solid-State Potentiometric Ion Sensor Base On Crown-Ether Compounds In this work,a novel absolutely solid-state contact PVC-membrane ion-selective electrodes were produced. For this by using crown-ether compounds (neutral ionophore) such as Ionophore 1; 4,4'-Bis[4“-phenoxy(15-crown-5)methyl]benzyl and Ionophore 2; 2,3-(4'-Aminobenzo)-8,9: 14, 1 5-dibenzo-7, 1 6-dithia- 1,4-dioxa- 1 0, 1 3-diazacyclooctadecane the electrodes were prepared. The potantiometric performance characteristics of the electrodes were investigated in a computerised measurement system.lt was concluded that the electrode prepared with ionophore 1 was especially selective towards K+ ion; the electrode prepared with ionophore 2 was selective towards H* ion; meaning it is a pH sensor; and selective towards Fe3+. While the electode prepared with ionophore 1 showes Nernst behaviour towards K+ solution (>55(±15) mV/per 10 times change), the response times are short (<10 s) and the life times are long (at least 1-2 months). All electrodes show linear behaviour towards main ion solution in the concentration interval 1.10”2-1.10“5 moLL”1. On the electrode prepared with ionophore 2 the potantial differences, which occurs for each Fe3+ solution containing a concentration differce of 10 units are around (58±30) mV.The response times are short (<15 s) and the life times are long (at least 1-2 months).The prepared electrodes show linear behaviour towards main ion solution in the concentration interval LlO^-l.lO“5 moLL”1. While the PVC-membrane ff^ selective electrode which was developed with ionophore 2 showes linear behaviour between pH 2-1 1,the potential diffence occurring for each ph difference is around (69±20) v.The response times are short (<10 s) and the life times are long (at least 1-2 months). The electrodes' selectivity coefficients relating to the ions which do interference besides the main ion were calculated with“separate solution method”.

Benzer Tezler

  1. Benzen birimleri içeren N1N1-disübstitüe 18-crown-6 eter türevlerinin hazırlanması

    Preparation of N1N1-disübstitued mono and dibenzo 18-crown-6 ether derivatives

    NADİR DEMİREL

    Yüksek Lisans

    Türkçe

    Türkçe

    1999

    KimyaDicle Üniversitesi

    Kimya Ana Bilim Dalı

    PROF.DR. HALİL HOŞGÖREN

  2. 2,3-dihidroksi-9,10-antrakinon makro halkalı eter ve podand türevlerinin hazırlanması

    Synthesis and podands derivatives of 9,10-anthraquinone-2,3-crown ethers

    MEHTAP ARICAN

    Doktora

    Türkçe

    Türkçe

    2002

    Kimyaİstanbul Teknik Üniversitesi

    Organik Kimya Ana Bilim Dalı

    PROF. DR. ÇAKIL ERK

  3. Yeni makrosiklik bileşiklerin sentezi ve iyon seçimliliğinin incelenmesi

    The Synthesis of new macrocylic compounds and investigation of their ion sellective effects

    ÜMMÜHAN OCAK

    Yüksek Lisans

    Türkçe

    Türkçe

    1994

    KimyaKaradeniz Teknik Üniversitesi

    Kimya Ana Bilim Dalı

    DOÇ. DR. H. BASRİ ŞENTÜRK

  4. Benzo-15-crown-5 içeren vic-dioksimler ve geçiş metal komplekslerinin sentezi

    Synthesis of vic-dioximes with benzo-15-crown-5 and their transition complexes

    RİFAT BATTALOĞLU

    Doktora

    Türkçe

    Türkçe

    2002

    KimyaNiğde Üniversitesi

    Kimya Ana Bilim Dalı

    YRD. DOÇ. DR. ALİ İHSAN PEKACAR

  5. Bazı yeni“taç eterlerinin”komplekslerinin hazırlanması, yapılarının aydınlatılması

    The Synthesis of some crown ethers and their complexes and the investigation of their structures

    AYHAN YILMAZ

    Doktora

    Türkçe

    Türkçe

    1996

    KimyaAnkara Üniversitesi

    PROF.DR. NECLA GÜNDÜZ