Geri Dön

Manyetik alanda Na+/K+ATP'az (EC:3.6.1.37) enzim aktivitesi, MDA ve GSH düzeylerinin araştırılması

Investigation of Na+/K+ATP'ase (EC:3.6.1.37) enzyme activity,MDA and GSH levels in static magnetic fields

  1. Tez No: 163289
  2. Yazar: PETEK USLU
  3. Danışmanlar: PROF.DR. MEHMET GÜRBİLEK
  4. Tez Türü: Doktora
  5. Konular: Biyokimya, Biochemistry
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2005
  8. Dil: Türkçe
  9. Üniversite: Selçuk Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Biyokimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

6. ÖZET S.Ü Sağlık Bilimleri Enstitüsü BİYOKİMYA ( TIP ) Anabilim Dalı Doktora Tezi / KONYA - 2005 Petek USLU Danışman Prof. Dr. Mehmet GÜRBİLEK Manyetik Alanda Na+ / K+ ATP'az ( EC:3.6.1.37 ) Enzim Aktivitesi, MDA ve GSH Düzeylerinin Araştırılması Bu çalışmada bir alümünyum fabrikasında elektrolizhanelerde çalışan işçilerde kronik statik manyetik alana maruziyetin Lipit peroksidasyonu,GSH ve Na+ / K+ ATP'az üzerindeki etkilerini görmek amacıyla 50 kişilik işçi ve 50 kişilik kontrol grubunda, kontrol gurubunun iş sebebiyle manyetik alana maruz kalmayan kişilerden ve işçi grubuyla aynı yaşlar arasında olmasına dikkat edilerek her iki grupta da kan örnekleri 10 cc anti koagülanh olarak alınmış MDA, GSH düzeyleri ve Na+ / K+ ATP'az ( E C 3.6.1.37 ) enzim aktivitesi ölçülmüştür. İşçilerde ve kontrol grubunda kan örneklerinde ölçülen parametrelerin ortalama ve standart sapma değerleri verilmiştir. MDA İŞÇİ ; 5,183 ± 0,370 nmol / mi, MDA kontrol ; 3,770 ± 0,645 nmol / gHb, GSH işçi ; 7,813 ± 0,454 mmol / gHb, GSH kontroi ; 3,640 ± 0,547 mmol / gHb, Na+ / K+ ATP'az jşçi ; 0,128 ± 0,022 umol.mprf'.lOdak, Na+ / K+ ATP'az kontroi ; 0,141 ± 0,023 umol.mprf'.lOdak. Veriler bilgisayar ortamına aktarılarak, istatistiki analiz SPSS for Windows V.12 istatistik paket programı kullanılarak yapıldı. Manyetik ve elektrik alanlara ( NIR ) yani non iyonize radyasyona kronik maruziyet sonucu MDA işçi grubunda fark MDA kontrol grubuna göre anlamlı olarak yüksek bulunmuştur. ( P <0,0001 ). GSH işçi düzeyleri, GSH kontrol grubuna anlamlı 46olarak yüksek bulunmuştur (P<0,0001 ). Na / K ATP'az işçi düzeyleri Na / K ATP'az kontrol düzeylerine göre düşüktür. İstatistiki olarak anlamlı bir fark vardır (P < 0,05 ). İşi sebebiyle noniyonize radyasyona (NIR)'a maruz kalanlarda MDA düzeyleri ve GSH düzeyleri yükselme yönünde Na+ / K+ ATP'az enzim aktivitesi azalma yönünde etkilenmektedir. Sonuç olarak noniyonize radyasyonun ( NIR ) bulunduğu yerlerde ki bunlara baz istasyonları ve trafoların civarını da eklemek gerekir. Maruziyet açısından sınır ve standart değerlerin tekrar gözden geçirilmesi son derece önemlidir. Bu iş güvenliği ve işçi sağlığı açısından önemli olduğu gibi gelecek nesilleri manyetik ses kirliliğinden uzak tutmak için de önemlidir. 47

Özet (Çeviri)

7. SUMMARY S.Ü Sağlık Bilimleri Enstitüsü BİYOKİMYA ( TIP ) Anabilim Dalı Doktora Tezi / KONYA - 2005 Petek USLU Danışman Prof. Dr. Mehmet GÜRBİLEK Investigation of Na+/K+ ATP'ase (EC:3.6.1.37) Enzyme Activity, MDA and GSH Levels in Static Magnetic Fields Investigation of the occupational exposure effects of static magnetic fields among workers of aluminium industry work in the area of electrolysis processes and the relationship of altering levels of MDA, GSH and Na+ / K+ ATP ase ( EC: 3.6.1.37 ) function control group which is not working in the same occasion. Our study includes 50 individual of workers group versus 50 individual of control group. The workers groupe was found in the risk of area because of their occupation 8 hours a day, 7 days per week. The control groupe was not working in a spesific exposure area or in the same occasion. In both of the groups the blood samples were taken 10 cc with anticoagulant and worked immediately for the three parameters which we analyzed. The mean ± standart deviation of the parameters are as follows; MDA worker 5.183 ± 0.370 n mol / ml, MDA control 3.770 ± 0.645nmol/gHb GSH worker 7.813 ± 0.454 mmol / gHb, GSH contro, 3.640 ± 0.547 mmol / gHb ; Na+ / K+ ATP'ase worker 0.128 ± 0.022 mmolmprt"1. 10 min. Na+/ K + ATP' ase control 0.141 ± 0.023 mmolprt ~x. 10 min. 48We used SPSS version 12 statistics programme for statistical analyses we used student's t test. According to t test there is significant difference between both parameters. MDA workers levels are higher than MDA control levels(P<0,0001 ). GSH workers levels are higher than GSH control groupe (P<0,0001 ). Na+ / K+ ATP'ase enzyme function of workers are lower than Na+ / K+ ATP'ase enzyme function of the control groupe (P<0,05 ). So, we can say as a conclusion; occupational exposure to NIR, changes the levels of Na+ / K+ ATP'ase enzyme function and MDA and GSH levels of the individuals what we can do for the problem is obvious we should take into account the limits and standarts of NIR. This is so important for both work and workers health and as for our next generation we should avoid magnetic sound pollution on our earth. 49

Benzer Tezler

  1. AC Manyetik alanın sıçanlarda biyomekanik ve hematolojik parametrelere etkisinin araştırılması

    Effects of AC magnetic fields on biomechanical and hematologic parameters in the rat.

    AYŞE DEMİRKAZIK

    Yüksek Lisans

    Türkçe

    Türkçe

    1995

    BiyofizikÇukurova Üniversitesi

    Biyofizik Ana Bilim Dalı

    DOÇ. DR. İSMAİL GÜNAY

  2. Batı Anadolu'nun neotektonik rejiminin paleomanyetik çalışmalarla incelenmesi

    Investigation of the neotectonic regime of Western Anatolia by means of paleomagnetic studies

    TURGAY İŞSEVEN

    Doktora

    Türkçe

    Türkçe

    2001

    Jeofizik Mühendisliğiİstanbul Teknik Üniversitesi

    PROF. DR. MUZAFFER SANVER

  3. Radiküler kist ve granülomların dijital histogram analizi ile ayırdedilmesi

    Differention of radicular cyst and granulomas with digital histogram analysis

    ÜLKEM AYDIN

    Doktora

    Türkçe

    Türkçe

    1998

    Diş HekimliğiGazi Üniversitesi

    Diş Hastalıkları ve Tedavisi Ana Bilim Dalı

    PROF. DR. TAYFUN ALAÇAM

  4. Fiziksel ölçümlerde sensörler

    The Sensors at the physical measurements

    GÖKHAN SERBEST

    Yüksek Lisans

    Türkçe

    Türkçe

    2000

    Fizik ve Fizik Mühendisliğiİstanbul Üniversitesi

    YRD. DOÇ. DR. BERKAY GÖRGEZ