Geri Dön

Bursa doğu atıksu arıtma tesisinde azot gideriminin ASM1 modeli-SSSP programı kullanılarak modellenmesi

Modelling of Bursa eastern wastewater treatment plant with respect to nitrogen removal by using ASM1 model-SSSP software

  1. Tez No: 154129
  2. Yazar: İLDEM TÜZEMEN
  3. Danışmanlar: Y.DOÇ.DR. SEVAL SOLMAZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Belirtilmemiş.
  7. Yıl: 2004
  8. Dil: Türkçe
  9. Üniversite: Uludağ Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET BURSA DOĞU ATIKSU ARITMA TESİSİNDE AZOT GİDERİMİNİN ASM1 MODELİ- SSSP PROGRAMI KULLANILARAK MODELLENMESİ Bu tez çalışması kapsamında, 2006 yılında işletmeye alınması planlanan ve inşaatı halen devam eden Bursa Doğu Atıksu Arıtma Tesisi' nde evsel atıksular için projelendirilen nitrifikasyon- denitrifîkasyon sisteminde azot giderimi ASM1 (Activated Sludge Model 1) matematik modeli ile SSSP (Simulation of Sludge Processes) bilgisayar programı çalıştırılarak modellenmiştir. Nitrifikasyon- denitrifîkasyon sisteminde azot giderimi açısından Bardenpho ve Kademeli Besleme Proseslerinin performansları, normal işletme şartlarında ve tanklardan biri devre dışı kalması durumunda, 10°C ve 20°C su sıcaklıklarında farklı içsel geridevir (%0- %600) oranlarında değerlendirilmiştir ve tesis projelendirilirken hedeflenen 10mg/l çıkış toplam N konsantrasyonunun bu proseslerle sağlanıp sağlanmadığı incelenmiştir. Çalışma neticesinde, en iyi çıkış veriminin, %400- %500 içsel geri devir oram ile sağlandığı görülmüştür. %500 içsel geri devir oram ile daha düşük çıkış konsantrasyonu elde edilebildiği halde, 20°C su sıcaklığında %400 içsel geri devir oram hedeflenen lOmg/1 çıkış toplam N konsantrasyonunun sağlanması için yeterli olmaktadır. Normal işletme şartlarında; su sıcaklığı 20°C olduğunda, toplam azot giderimi açısından optimum verim %400 geri devir oram ile Bardenpho Prosesiyle sağlanmaktadır. Bakım şartlarında da, yani tanklardan biri devre dışı kaldığında da, en optimum verim %400 geri devir oram ile sağlanmaktadır. Normal işletme şartlarında; su sıcaklığı 10°C olduğunda, Kademeli Besleme Prosesi ile daha yüksek azot giderimi %500 içsel geri devir oram ile sağlanmaktadır. Ancak su sıcaklığı 20°C olduğunda, toplam çıkış azot konsantrasyonu, hedeflenen 10mg/l değerinin altında elde edilebildiği halde, su sıcaklığı 10°C olduğunda, normal işletme ve bakım şartlarında hedeflenen lOmg/l çıkış değeri sağlanamamaktadır. Nisan2003-Mart2004 tarihleri arasında laboratuvarda mevcut ön arıtma tesisine gelen ham atıksuda yapılan analizlere göre, yaklaşık üç aylık süre boyunca (Aralık, Ocak, Şubat) su sıcaklığı ~10°C olmaktadır. Bu durumda, tesisin işletme parametrelerinde (özellikle reaktördeki MLSS konsantrasyonu, çamur yaşı, Vq/ Vt (denitrifîkasyon hacmi/ toplam hacim) oram) optimum düzenlemeler yapılarak arıtma veriminin iyileştirilmesi sağlanabilir.

Özet (Çeviri)

11 ABSTRACT MODELLING OF BURSA EASTERN WASTEWATER TREATMENT PLANT WITH RESPECT TO NITROGEN REMOVAL BY USING ASM1 MODEL- SSSP SOFTWARE In this thesis study, nitrogen removal by nitrification-denitrification system of Bursa Eastern Domestic Wastewater Treatment Plant which is being constructed and foreseen to be in operation in 2006 was simulated according to ASM 1 (Activated Sludge Model 1) mathematical model by using SSSP (Simulation of Sludge Processes) software. Nitrogen removal performances of Bardenpho and Step-feed processes in nitrification- denitrification system were evaluated in normal operation conditions and the condition of one tank is shut down at 10°C and 20°C water temperature and different internal recirculation rates (%0- %600). With this study, also it was investigated whether the Total N concentration of effluent (10mg/l) could be achieved or not by means of designed process. As a conclusion of this study, the best efficiency is achieved by 400%- 500% internal recirculation rates. Although lower Total N effluent concentrations are achieved by 500% internal recirculation rate at 20°C water temperature, 400% internal rate is sufficient to achieve 10mg/l Total N effluent concentration. In normal operation conditions, at 20°C water temperature, optimum nitrogen removal efficiency is achieved by 400% internal rate with Bardenpho Process. In maintaince conditions (one tank is shut down), optimum efficiency is achieved by 400% internal rate. In normal operation conditions, 10°C water temperature, optimum nitrogen removal efficiency is achieved by 500% internal rate with Step-feed Process. The required 10mg/l Total N effluent concentration could be satisfied at 20°C however when the water temperature drops to 10°C, nitrogen removal efficiency could not be enough to satisfy required 10mg/l in both normal operation and maintaince conditions. Influent analysis performed on April2003-March2004 indicates that the influent temperature is being ~10°C approximately 3months (December, January, February) in a year. In this case, the operation parameters of the plant (especially, MLSS concentration in the reactor, sludge age, Vd/ Vj (denitrification volume/ total volume) rate) can be optimized in order to improve treatment efficiency.

Benzer Tezler

  1. Türkiye' deki bazı atıksu arıtma tesislerinden çıkan atık çamurların bitki besin elementleri ve ağır metal içeriklerinin yıl içindeki değişimi

    In-year variations in plants nutrients and heavy metal content of sewage sludge derived from some wastewater treatment plants in turkey

    DİLEK TERZİ

    Yüksek Lisans

    Türkçe

    Türkçe

    2007

    ZiraatAnkara Üniversitesi

    Toprak Ana Bilim Dalı

    PROF.DR. İLHAN KARAÇAL

  2. CPT based compressibility assessment of soils

    Konik penetrasyon deneyi (CPT) verilerini kullanarak zeminin sıkışabilirliğinin belirlenmesi

    FATMA ÖZKAHRİMAN

    Yüksek Lisans

    İngilizce

    İngilizce

    2004

    İnşaat MühendisliğiOrta Doğu Teknik Üniversitesi

    İnşaat Mühendisliği Ana Bilim Dalı

    DOÇ. DR. KEMAL ÖNDER ÇETİN

    PROF. DR. ORHAN EROL

  3. Çeşitli susuzlaştırma yöntemlerinin arıtma çamurlarındaki patojen mikroorganizmalar üzerine etkisi

    Impact of various dewatering methods on pathogenic micro-organisms in treatment sludges

    BÜLENT BİRDEN

    Yüksek Lisans

    Türkçe

    Türkçe

    2006

    Çevre MühendisliğiUludağ Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. UFUK ALKAN

  4. Bursa şehir merkezinden kaynaklanan atıksular, arıtılmaları ve Nilüfer Çayı'na etkileri

    Wastewaters originated from the city center of Bursa, their treatments and their effects to the Nilüfer Creek

    AYSIN GİRAY KAYNAK

    Yüksek Lisans

    Türkçe

    Türkçe

    2002

    Çevre MühendisliğiUludağ Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    DOÇ. DR. YÜCEL TAŞDEMİR

  5. Doğu Bursa Ovası hidrojeoloji modellemesi ve sorunları

    Hydrogeological modelling of East Bursa Plain and its hydrogeological situation

    ERTAN MERT

    Doktora

    Türkçe

    Türkçe

    2003

    Jeoloji MühendisliğiKocaeli Üniversitesi

    Jeoloji Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. ÖZKAN CORUK