Bursa doğu atıksu arıtma tesisinde azot gideriminin ASM1 modeli-SSSP programı kullanılarak modellenmesi
Modelling of Bursa eastern wastewater treatment plant with respect to nitrogen removal by using ASM1 model-SSSP software
- Tez No: 154129
- Danışmanlar: Y.DOÇ.DR. SEVAL SOLMAZ
- Tez Türü: Yüksek Lisans
- Konular: Çevre Mühendisliği, Environmental Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2004
- Dil: Türkçe
- Üniversite: Uludağ Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZET BURSA DOĞU ATIKSU ARITMA TESİSİNDE AZOT GİDERİMİNİN ASM1 MODELİ- SSSP PROGRAMI KULLANILARAK MODELLENMESİ Bu tez çalışması kapsamında, 2006 yılında işletmeye alınması planlanan ve inşaatı halen devam eden Bursa Doğu Atıksu Arıtma Tesisi' nde evsel atıksular için projelendirilen nitrifikasyon- denitrifîkasyon sisteminde azot giderimi ASM1 (Activated Sludge Model 1) matematik modeli ile SSSP (Simulation of Sludge Processes) bilgisayar programı çalıştırılarak modellenmiştir. Nitrifikasyon- denitrifîkasyon sisteminde azot giderimi açısından Bardenpho ve Kademeli Besleme Proseslerinin performansları, normal işletme şartlarında ve tanklardan biri devre dışı kalması durumunda, 10°C ve 20°C su sıcaklıklarında farklı içsel geridevir (%0- %600) oranlarında değerlendirilmiştir ve tesis projelendirilirken hedeflenen 10mg/l çıkış toplam N konsantrasyonunun bu proseslerle sağlanıp sağlanmadığı incelenmiştir. Çalışma neticesinde, en iyi çıkış veriminin, %400- %500 içsel geri devir oram ile sağlandığı görülmüştür. %500 içsel geri devir oram ile daha düşük çıkış konsantrasyonu elde edilebildiği halde, 20°C su sıcaklığında %400 içsel geri devir oram hedeflenen lOmg/1 çıkış toplam N konsantrasyonunun sağlanması için yeterli olmaktadır. Normal işletme şartlarında; su sıcaklığı 20°C olduğunda, toplam azot giderimi açısından optimum verim %400 geri devir oram ile Bardenpho Prosesiyle sağlanmaktadır. Bakım şartlarında da, yani tanklardan biri devre dışı kaldığında da, en optimum verim %400 geri devir oram ile sağlanmaktadır. Normal işletme şartlarında; su sıcaklığı 10°C olduğunda, Kademeli Besleme Prosesi ile daha yüksek azot giderimi %500 içsel geri devir oram ile sağlanmaktadır. Ancak su sıcaklığı 20°C olduğunda, toplam çıkış azot konsantrasyonu, hedeflenen 10mg/l değerinin altında elde edilebildiği halde, su sıcaklığı 10°C olduğunda, normal işletme ve bakım şartlarında hedeflenen lOmg/l çıkış değeri sağlanamamaktadır. Nisan2003-Mart2004 tarihleri arasında laboratuvarda mevcut ön arıtma tesisine gelen ham atıksuda yapılan analizlere göre, yaklaşık üç aylık süre boyunca (Aralık, Ocak, Şubat) su sıcaklığı ~10°C olmaktadır. Bu durumda, tesisin işletme parametrelerinde (özellikle reaktördeki MLSS konsantrasyonu, çamur yaşı, Vq/ Vt (denitrifîkasyon hacmi/ toplam hacim) oram) optimum düzenlemeler yapılarak arıtma veriminin iyileştirilmesi sağlanabilir.
Özet (Çeviri)
11 ABSTRACT MODELLING OF BURSA EASTERN WASTEWATER TREATMENT PLANT WITH RESPECT TO NITROGEN REMOVAL BY USING ASM1 MODEL- SSSP SOFTWARE In this thesis study, nitrogen removal by nitrification-denitrification system of Bursa Eastern Domestic Wastewater Treatment Plant which is being constructed and foreseen to be in operation in 2006 was simulated according to ASM 1 (Activated Sludge Model 1) mathematical model by using SSSP (Simulation of Sludge Processes) software. Nitrogen removal performances of Bardenpho and Step-feed processes in nitrification- denitrification system were evaluated in normal operation conditions and the condition of one tank is shut down at 10°C and 20°C water temperature and different internal recirculation rates (%0- %600). With this study, also it was investigated whether the Total N concentration of effluent (10mg/l) could be achieved or not by means of designed process. As a conclusion of this study, the best efficiency is achieved by 400%- 500% internal recirculation rates. Although lower Total N effluent concentrations are achieved by 500% internal recirculation rate at 20°C water temperature, 400% internal rate is sufficient to achieve 10mg/l Total N effluent concentration. In normal operation conditions, at 20°C water temperature, optimum nitrogen removal efficiency is achieved by 400% internal rate with Bardenpho Process. In maintaince conditions (one tank is shut down), optimum efficiency is achieved by 400% internal rate. In normal operation conditions, 10°C water temperature, optimum nitrogen removal efficiency is achieved by 500% internal rate with Step-feed Process. The required 10mg/l Total N effluent concentration could be satisfied at 20°C however when the water temperature drops to 10°C, nitrogen removal efficiency could not be enough to satisfy required 10mg/l in both normal operation and maintaince conditions. Influent analysis performed on April2003-March2004 indicates that the influent temperature is being ~10°C approximately 3months (December, January, February) in a year. In this case, the operation parameters of the plant (especially, MLSS concentration in the reactor, sludge age, Vd/ Vj (denitrification volume/ total volume) rate) can be optimized in order to improve treatment efficiency.
Benzer Tezler
- Türkiye' deki bazı atıksu arıtma tesislerinden çıkan atık çamurların bitki besin elementleri ve ağır metal içeriklerinin yıl içindeki değişimi
In-year variations in plants nutrients and heavy metal content of sewage sludge derived from some wastewater treatment plants in turkey
DİLEK TERZİ
- CPT based compressibility assessment of soils
Konik penetrasyon deneyi (CPT) verilerini kullanarak zeminin sıkışabilirliğinin belirlenmesi
FATMA ÖZKAHRİMAN
Yüksek Lisans
İngilizce
2004
İnşaat MühendisliğiOrta Doğu Teknik Üniversitesiİnşaat Mühendisliği Ana Bilim Dalı
DOÇ. DR. KEMAL ÖNDER ÇETİN
PROF. DR. ORHAN EROL
- Çeşitli susuzlaştırma yöntemlerinin arıtma çamurlarındaki patojen mikroorganizmalar üzerine etkisi
Impact of various dewatering methods on pathogenic micro-organisms in treatment sludges
BÜLENT BİRDEN
Yüksek Lisans
Türkçe
2006
Çevre MühendisliğiUludağ ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
DOÇ. DR. UFUK ALKAN
- Bursa şehir merkezinden kaynaklanan atıksular, arıtılmaları ve Nilüfer Çayı'na etkileri
Wastewaters originated from the city center of Bursa, their treatments and their effects to the Nilüfer Creek
AYSIN GİRAY KAYNAK
Yüksek Lisans
Türkçe
2002
Çevre MühendisliğiUludağ ÜniversitesiÇevre Mühendisliği Ana Bilim Dalı
DOÇ. DR. YÜCEL TAŞDEMİR
- Doğu Bursa Ovası hidrojeoloji modellemesi ve sorunları
Hydrogeological modelling of East Bursa Plain and its hydrogeological situation
ERTAN MERT
Doktora
Türkçe
2003
Jeoloji MühendisliğiKocaeli ÜniversitesiJeoloji Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. ÖZKAN CORUK