Buzdolaplarında kullanılan seri sıralamalı (tandem) sistemlerin deneysel ve teorik incelenmesi
Experimental and theoretical investigation of the serial arrangement (tandem) refrigeration system in refrigerators
- Tez No: 151583
- Danışmanlar: PROF. DR. NİLÜFER EĞRİCAN
- Tez Türü: Yüksek Lisans
- Konular: Makine Mühendisliği, Mechanical Engineering
- Anahtar Kelimeler: Belirtilmemiş.
- Yıl: 2004
- Dil: Türkçe
- Üniversite: İstanbul Teknik Üniversitesi
- Enstitü: Fen Bilimleri Enstitüsü
- Ana Bilim Dalı: Makine Mühendisliği Ana Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
BUZDOLAPLARINDA KULLANILAN SERİ SIRALAMALI (TANDEM) SİSTEMLERİN DENEYSEL VE TEORİK İNCELENMESİ ÖZET Buzdolaplarında kullanılagelen çift buharlaştırıcılı, seri sıralamalı soğutma çevrimierinde temel olarak iki verimsizlik mevcuttur. Bunlardan ilki buzolabtnda yer alan taze gıda bölmesinin gerekenden daha düşük bir buharlaşma basıncında ve sıcaklığında soğutulmasıdır. Düşük buharlaşma sıcaklıkları kompresörün dolayısıyla da sistemin SHK'ini düşürmektedir. Bu nedenle taze gıda bölmesi için gerekenden daha düşük bir buharlaşma basıncında (buharlaşma sıcaklığında) soğutma yapılması verimsiz bir soğutma işlemine sebep olmaktadır. Bunun çözümü için taze gıda bölmesinin, kendisi için daha verimli olan yüksek bir buharlaşma basıncında yani buharlaşma sıcaklığında soğutulması gerekmektedir. Bunu yaparken ise bu çalışmada kompresörün kalkış anından itibaren başlayan ve çevrim alt ve üst basınçları (buharlaşma ve yoğuşma basınçları) dengeye gelene kadar devam eden geçici rejim koşullan (aralığı) taze gıda bölmesinin soğutulmasında kullanılmıştır. Geçici rejim süresinden etkin bir şekilde yararlanmak için taze gıda buharlaştıncısı olarak zorlanmış taşınımlı bir bııharlaştırıcı kullanılmıştır. Diğer bir verimsizlik ise dondurucu buharlaştıncısı tanının çalışma zamanlamasından kaynaklanmaktadır. Kompresörün durmasıyla birlikte yüksek basınçlı basma hattı ile düşük basınçlı emme hattı arasındaki basınç farkından ötürü bir soğutkan göçü meydana gelmektedir. Bu göç neticesinde kompresör çalışmaz iken buharlaştırıcılar ısınmakta ve kompresörün çalışmaya başlamasıyla birkaç dakika bölmelerini soğutamamakta aksine bölmelerine ısıtabilmektedirier. Bu yüzdendir ki, kompresörün çalışmaya başlamasıyla birlikte özellikle dondurucu buharlaştıncısı fanının da çalışmaya başlaması dondurucu bölmesinin ısı yükünü artırmaktadır. Bu durumun çözümü için ise dondurucu fanı kompresör çalışmasını takiben belli bir süre sonra çalıştırılmıştır.
Özet (Çeviri)
EXPERIMENTAL AND THEORETICAL INVESTIGATION OF THE SERIAL ARRANGEMENT (TANDEM) REFRIGERATION SYSTEM IN REFRIGERATORS SUMMARY The current conventional domestic serial cycles have two main inefficiencies. One of said inefficiencies is inappropriate pressure levels for cooling fresh food compartment. Lower evaporation pressure than required degrades COP of compressor and refrigeration system. Therefore, the refrigeration cycle operates inefficiently to keep the fresh food compartment at desired temperatures with inappropriate (lower) evaporation levels. In this study, transient regime was used to cool fresh food compartment. During the transient regime, evaporation temperature and pressure levels are suitable to provide efficient cooling for the fresh food compartment while evaporation pressure and temperature are higher than desired levels for the freezer compartment. Fresh food evaporator was changed from cold- wall natural-convection heat exchanger to forced-convection heat exchanger to enhance the transient regime effects on cooling of fresh food compartment. The other inefficiency is related to the start time of freezer evaporator fan according to the compressor. When the compressor starts to operate, the FRZ evaporator can't cool its compartment in first few minutes because of increased evaporator temperature due to refrigeration migration during the compressor off period. Moreover, working of the freezer fan in this period cause extra heat load to the its cabinet. Therefore, in this study, freezer fan was started to operate after the adequate time of the compressor initiation.
Benzer Tezler
- Buzdolaplarında kullanılan buhar sıkıştırmalı soğutma çevrimlerinin enerji ve ekserji analizi ile incelenmesi
The study of vapor-compression refrigeration cycles in refrigerators via energy and exergy analysis
AYŞE BİLGEN EKİN
Yüksek Lisans
Türkçe
2008
Makine MühendisliğiCelal Bayar ÜniversitesiMakine Mühendisliği Bölümü
DOÇ. DR. YUNUS ÇERÇİ
- Experimental evaluation of air-cooled condensers for household refrigerators
Ev tipi buzdolaplarında kullanılan hava soğutmalı kondenserlerin deneysel olarak değerlendirilmesi
ELİF DİRGİN
Yüksek Lisans
İngilizce
2002
Makine MühendisliğiOrta Doğu Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF. DR. RÜKNETTİN OSKAY
- Vakumlu izolasyon panellerinin ısı iletim katsayılarının deneysel olarak incelenmesi
An Experimental investigation on the thermal conductivity of vacuum insulated panels
FEYZİ ALPER SOYSAL
- Bir buzdolabı buharlaştırıcısının ısıl hirolik performansının sayısal incelenmesi
Numerical investigation of thermohydraulic performance of a refrigerator evaporator
TUĞBA SARIÇAY
Yüksek Lisans
Türkçe
2006
Makine MühendisliğiEskişehir Osmangazi ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
PROF.DR. BERRİN ERBAY
- Hermetik pistonlu kompresörlerde sürtünme kayıplarının incelenmesi
The investigation of frictional losses in hermetic reciprocating compressors
MEHMET ERDEM TURFAN
Yüksek Lisans
Türkçe
2005
Makine Mühendisliğiİstanbul Teknik ÜniversitesiMakine Mühendisliği Ana Bilim Dalı
YRD. DOÇ. DR. İSMAİL GERDEMELİ