Geri Dön

Simple, low-cost biosignal amplifier design for ECG and EEG

EKG ve EEG biyolojik işaretleri için basit, düşük maliyetli sinyal kuvvetlendirici dizaynı

  1. Tez No: 151477
  2. Yazar: ABDULAZİZ AYDIN
  3. Danışmanlar: Y.DOÇ.DR. TURGUT İKİZ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Sinyal kuvvetlendirici, biyolojik işaret yükseltec, ECG, EEG, Filtre, Instrumentation amplifier, biosignal amplifier, ECG, EEG, Filter. n
  7. Yıl: 2004
  8. Dil: İngilizce
  9. Üniversite: Çukurova Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Elektrik-Elektronik Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

oz YÜKSEK LİSANS TEZİ SIMPLE, LOW-COST BIOSIGNAL AMPLIFIER DESIGN FOR ECG AN» EEG Abdulaziz AYDIN ÇUKUROVA ÜNİVERSİTESİ FEN BİLİMLERİ ENSTİTÜSÜ ELEKTRİK-ELEKTRONİK ANABİLİM DALI Danışman :Yard. Doç. Dr. Turgut İKİZ Yıl : 2004, Sayfa: 78 Jüri :Yard. Doç. Dr. Turgut İKİZ ?.Yard. Doç. Dr. Sami ARICA : Yard. Doç. Dr. Mustafa ORAL Bu çalışmada ECG ve EEG biyolojik işaret yükselteci tasarlandı. ECG sistemi kullanılarak bipolar, monopolar gibi standart bağlantılar ölçülebilmektedir. Aynı şekilde monopolar, bipolar, yaklaşık hjort ölçümleri ticari biyolojik işaret yükselteçlerinde olduğu gibi yüksek kalitede EEG sistemi ile ölçüm yapılabilmektedir. Her iki sistemde portatif olduğundan dolayı kolayca her tarafta taşınabilir. Sistemin kalitesi korunarak, sinyal kuvvetlendirici katında ayrık elemanlar kullanılıp fiyatı oldukça düşük bir seviyede tutulmuştur. Herhangi bir arıza durumunda elemanlar kolayca temin edilip değiştirilebilir. Bu çalışmada çift kanallı 0.05Hz-100Hz frekans aralığına sahip kalp işaretlerini ölç en ECG ve 1.5Hz-37Hz frekans aralığına sahip beyin işaretlerini ölçen EEG sistemi tasarlanmış olup, sonunda uygulama aşamasında karşılaşılan problemler çözümler ile birlikte verilmiştir.

Özet (Çeviri)

ABSTRACT M.Sc. THESIS SIMPLE, LOW-COST BIOSIGNAL AMPLIFIER DESIGN FOR ECG AND Abdulaziz AYDIN DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING INSTITUTE OF NATURAL AND APPLIED SCIENCES UNWERISTY OF ÇUKUROVA Supervisor : Assist. Prof. Dr. Turgut İKİZ Year : 2004, Pages: 78 Jury : Assist. Prof. Dr. Turgut İKİZ Assist. Prof. Dr. Sami ARICA Assist. Prof. Dr. Mustafa ORAL In this study, ECG and EEG biosignal amplifiers were designed. Standard lead systems such as bipolar limb leads and unipolar limb leads can be measured by using the ECG system. In addition, monopolar, bipolar and approximately hjort measurements can be measured at high quality by the EEG system like commercial biosignal amplifier. Because of both of the systems are modular, they are very portative and can move everywhere easily. Also at the stage of instrumentation amplifier, discrete components were used to decrease cost of the circuit together by keeping quality of amplifier. In any failure, components used in the systems can be founded easily. In this study, the design and implementation of dual channels ECG circuit with 0.05 - 100 Hz bandwidth that is used to pick up signals of heart and EEG circuit with 1.5 - 37 Hz bandwidth that is used to measure activities of brain were evaluated, designed and the faced problems were given with their solutions together.

Benzer Tezler

  1. Uncooled infrared focal plane arrays with integrated readout circuitry using MEMS and standard CMOS technologies

    MEMS ve standart CMOS teknolojileri ile entegre okuma devreli soğutmasız kızılötesi odak düzlem matrisleri

    SELİM EMİNOĞLU

    Doktora

    İngilizce

    İngilizce

    2003

    Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. TAYFUN AKIN

  2. Surface micromachined capacitive accelerometers using MEMS technology

    MEMS teknolojisi ile yüzey mikroişlenmiş kapasitif ivmeölçerler

    REFET FIRAT YAZICIOĞLU

    Yüksek Lisans

    İngilizce

    İngilizce

    2003

    Elektrik ve Elektronik MühendisliğiOrta Doğu Teknik Üniversitesi

    Elektrik-Elektronik Mühendisliği Ana Bilim Dalı

    DOÇ. DR. TAYFUN AKIN

  3. Çevik üretimdeki ürün farklılıklarının ertelenmesi için üretim sistemlerinin çizelgelenmesi ve bir işletme uygulaması

    Scheduling manufacturing systems for delayed product differentiation in agile manufacturing and a company application

    PERİHAN BAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2004

    İşletmeİstanbul Üniversitesi

    İşletme Ana Bilim Dalı

    DOÇ. DR. NECDET ÖZÇAKAR

  4. Düşük maliyetli bir fruktozamin testinin otomasyonu; laboratuvar performansı ve klinikyararlılığının değerlendirilmesi

    Automation of low cost fructosamine assay; evaluation of the laboratory performance and clinical usefullness

    TUNCAY KÜME

    Tıpta Uzmanlık

    Türkçe

    Türkçe

    2003

    BiyokimyaDokuz Eylül Üniversitesi

    Biyokimya Ana Bilim Dalı

    PROF. DR. BANU ÖNVURAL

  5. Cold pressure and resistance welding of copper wires

    Bakır tellerin soğuk basınç ve direnç kaynağı

    AYŞEGÜL EFE

    Yüksek Lisans

    İngilizce

    İngilizce

    2000

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    PROF.DR. HÜSEYİN ÇİMENOĞLU