Geri Dön

Motion artifact reduction techniques in magnetic resonance imaging

Başlık çevirisi mevcut değil.

  1. Tez No: 15111
  2. Yazar: ERGİN ATALAR
  3. Danışmanlar: DOÇ.DR. LEVENT ONURAL
  4. Tez Türü: Doktora
  5. Konular: Elektrik ve Elektronik Mühendisliği, Electrical and Electronics Engineering
  6. Anahtar Kelimeler: Manyetik Rezonans Görüntüleme, Manyetik Rezonans Görüntülemede Kıpırtı Etkilerinin Giderilmesi, Görüntü Bozuklukları 11, Görüntü bozuklukları, Magnetic Resonance Imaging, Motion Artifact Reduction in MRI, Respiratory Motion Artifact, Image deformations, Magnetic resonance imaging
  7. Yıl: 1991
  8. Dil: İngilizce
  9. Üniversite: İhsan Doğramacı Bilkent Üniversitesi
  10. Enstitü: Mühendislik ve Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Belirtilmemiş.
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

Özet MANYETİK REZONANS GÖRÜNTÜLEMEDE KIPIRTI BOZUKLUKLARININ GİDERİLME YÖNTEMLERİ Ergin Atalar Elektrik ve Elektronik Mühendisliğinde Doktora Tez Yöneticisi: Doç. Dr. Levent Onural Temmuz 1991 Manyetik rezonans görüntülemede, görüntülenen cismin dönme ve genişleyip daralma hareketlerinin toplanan verilerin evre ve genliklerinde bozukluklara ve Fourier dönüşüm düzlemindeki örneklerin istenenden farklı yerlere alınmasına neden olduğu gösterilmiştir. Gerekli düzeltmeler yapılmazsa görüntülerde“kıpırtı bozuklukları”oluşur. Hareket ile bozukluklar arasındaki matematiksel ilişkiler verilmiştir. Cismin nasıl kıpırdadığı tam olarak biliniyorsa, net görüntülerin elde edilmesi mümkündür. Önerilen yöntemde, elde edilen verilerden ya da doğrudan ölçümlerden cismin hareketi kestirilir. Bu kestirim sonuçlarını ve bilmen hareket-bozulma ilişkisini kullanarak evre ve genliklerdeki hatalar düzeltilir. Fourier düzleminde ölçümlerle elde edilmiş örnekler kullanılarak tekil değer ayrışımı yöntemi ile düzgün aralıklı yerleşik yeni örnekler hesaplanır. Son olarak da bu hesaplanan değerlerin ters Fourier dönüşümü alınarak bozukluğu giderilmiş görüntü elde edilir. Önerilen yöntem benzetim ile elde edilmiş veriler kullanılarak denenmiştir. Yukarıda belirtilen hareket kestirimi için de iki yöntem önerilmiş ve denemiştir. Bunlardan ilki bir tekrarlamak görüntü onarım yöntemidir, ikincisi ise yönlendirici yankı (navigator echo) kullanılarak kıpırdama miktarının bulunması ilkesine dayanmaktadır.

Özet (Çeviri)

Abstract MOTION ARTIFACT REDUCTION TECHNIQUES IN MAGNETIC RESONANCE IMAGING Ergin Atalar Ph. D. in Electrical and Electronics Engineering Supervisor: Assoc. Prof. Levent Onural July 1991 It is shown that the expansion/shrinkage and rotational motions of the body cause phase and amplitude distortions and non-rectangular sampling over the ^-domain. If these distortions are not compensated then the reconstructed image will suffer from“the motion artifact”. The mathematical relation between motion and motion artifact is given. If the motion of the body is known, it is possible to obtain motion artifact free images. The motion is estimated either by using the information in the acquired data or by direct measurement. These estimates and the relation between motion and artifact are used to compensate the phase and amplitude distortions. Using the non-rectangular samples over the A:-domain the rectangular samples are obtain by the aid of the singular value decomposition method. And finally, the inverse Fourier transform of these calculated samples gives the motion artifact free image. The proposed method is tested by simulations. For the estimation of the motion, two methods are proposed and tested. The first method is an iterative image reconstruction method. The second one uses the navigator echoes to obtain the amount of motion.

Benzer Tezler

  1. HDTV işaretlerinin uydu üzerinden iletiminde özel problemler

    Special problems in transmitting the HDTV signals by satellite

    RAMAZAN BAL

    Yüksek Lisans

    Türkçe

    Türkçe

    1991

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    PROF.DR. BİNGÜL YAZGAN

  2. Volgram ağır alaşımlarında başlangıç toz özelliklerinin sıvı gaz sinterlemesi yoluyla yoğunlaşma süreçlerine olan etkileri

    Effects of initial powder characteristics on densificatıon processes via liquid-phase sintering in based heavy alloys

    BURAK ÖZKAL

    Yüksek Lisans

    Türkçe

    Türkçe

    1994

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    DOÇ. DR. LÜTFİ ÖVEÇOĞLU

  3. Elektrokardiyografik işaretlerde QRS deteksiyon algoritmaları

    Başlık çevirisi yok

    MAHMUT KÖROĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1998

    Elektrik ve Elektronik Mühendisliğiİstanbul Teknik Üniversitesi

    Elektronik ve Haberleşme Mühendisliği Ana Bilim Dalı

    DOÇ. DR. MEHMET KORÜREK

  4. Otomatik aritmi dedeksiyonu

    Başlık çevirisi yok

    GÜNNUR ALANYALI

  5. Bulanık (Fuzzy) sınıflayıcılarla EKG şekil bozukluklarının belirlenmesi

    Detection of ECG shape changes by using fuzzy classifiers

    ZÜMRAY DOKUR

    Yüksek Lisans

    Türkçe

    Türkçe

    1995

    Biyomühendislikİstanbul Teknik Üniversitesi

    DOÇ.DR. MEHMET KORÜREK