Alt çene implant destekli overdenture protezlerde farklı tutucu tiplerinin ve değişik kret yüksekliklerinin implantlarda oluşan strain'e etkisi
The effect of attachment type and mandibular crest height on the strain induced on implants supporting overdentures
- Tez No: 129878
- Danışmanlar: DOÇ. DR. FİGEN DEMİREL
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: dental implant, overdenture, denture precision attachment, alveolar ridge, strain
- Yıl: 2003
- Dil: Türkçe
- Üniversite: Hacettepe Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protez Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZET Mersin, T., Ait Çene implant Destekli Overdenture Protezlerde Farklı Tutucu Tiplerinin Ve Değişik Kret Yüksekliklerinin İmplantlarda Oluşan Strain'e Etkisi, Hacettepe Üniversitesi Sağlık Bilimleri Enstitüsü Protez (Diş) Programı Doktora Tezi, Ankara, 2003. Bu çalışmada, implant destekli overdenture'larda iki farklı tutucu tipi ve üç farklı kret yüksekliğinin, implantlardaki straine etkisi araştırılmıştır. Kanin bölgelerinde, kölelerine rozet strain gauge yerleştirilmiş iki adet implant bulunan, yüksek rezidüel kretlere sahip, mandibular dişsiz, otopolimerizan akrilik rezin model elde edildi, ve mukozayı taklit eden, 1.5 mm kalınlığında bir plaka ite kaplandı. Altı adet bar/matriks tutuculu, altı adet topuz tutuculu overdenture hazırlandı ve tutucular, protezlerin ilgili bölgeleri delinerek otopolimerizan akrilik rezin akıtma yöntemi ite protezlere tutturuldu. Her bir protez medete yerleştirilerek üçer kez, posteriordan dikey yönde, çift taraflı ve eşzamanlı olarak 100, 150, 200, 300, 400 N statik kuvvet ite yüklendi. İmplantlardak i strain ve mukozayı taklit eden plakadaki deformasyon miktarı, eşzamanlı olarak kaydedildi, indeks yardımıyla protez kenarları kısaltılarak, orta ve düşük kret yüksekliklerini temsil eden protezler hazırlandı. Yükleme ve kayıt işlemleri ilk modeldeki gibi tekrarlandı. Veri toplama ve analog sinyal işleme sistemi ite elde edilen strain verileri ve deformasyon miktarları, tutucu tipleri arasında Mann Whitney U testi, kret yükseklikleri arasında Friedman testi ile istatistiksel olarak değerlendirildi. Topuz tutuculu protezler, bar tutuculu protezlerden istatistiksel olarak anlamlı düzeyde yüksek strain verilerine sahipti (p<0.05). Farklı kret yükseklikleri arasında ise fark bulunmadı (p>0.05). Farklı tutucu tipinin kullanıldığı iki protez grubundan ekte edilen deformasyon değerleri 200 N (p=0.065) dışındaki yüklerde, istatistiksel olarak anlamlıydı (p<0.05). Farklı kret yüksekliklerinde deformasyon mi ktarları arasındaki fark anlamlı bulundu, İmplant destekli overdenture'larda kullanılan tutucu tipinin, implantlar ile destek doku alanları arasında yük paylaşımını etkilediği saptandı, iki implantın da boyun kısımlarının lingualinde gerilme gözlendi. Overdenture'ların in vitro çalışma ortamında dikey yönde yüklenmesi ite alveolar kretin anatomisine bağlı olarak protezin anteriora doğru itilme eğilimi olduğu görüldü. Anahtar kelimeler, dental implant, overdenture, hassas tutucu, alveolar kret, strain, Destekleyen Kurumlan HÜAF OOT10102001 m Institute Straumann
Özet (Çeviri)
VI ABSTRACT Mersin, T., The effect of attachment type and mandibular crest height on the strain induced on implants supporting overdentures, Hacettepe University Health Sciences Institute PhD Thesis in Prosthodontics, Ankara, 2003. The purpose of this study was to investigate the strains induced on implants, supporting mandibular overdentures, with respect to two different attachment types and different amounts of alveolar bone resorption. In order to assess the strains on implants, a strain gauge rosette was bonded on the collar of each implant and was incorporated into the canine regions of an acrylic resin experimental model with high residual ridges. Experimental model was coated with 1.5 mm thick elastomeric material for tissue resiliency simulation. Ovoid-shaped bar attachments and ball attachments were used as retantive elements on implants and six specimens were constructed for each configuration. Each specimen was loaded with 400 N static axial force, applied on the posterior teeth bilaterally and simultaneously, for three times. For each loading sequence, strain induced on implant and deflection of mucosa simulant were recorded. Residual ridge height was altered by means of index moulds and loading - recording sequences were repeated for different residual ridge heights. Overdentures with ball attachments caused statistically significantly higher strain on implants and lower amount of deflection on tissue-bearing area than overdentures with bar attachments (p<0.05). Differences between different residual ridge heights were not statistically significant (p>0.05). As a result, attachment type used effects the load distribution between implants and edentulous ridge. Tension was observed at the lingual sides of the neck of the implants. Therefore, it can be predicted that, when loaded vertically in in vitro conditions, an anterior component of force is formed on the dentures, related with the anatomy of alveolar ridge.
Benzer Tezler
- Farklı implantlar ve tutucu elemanlar kullanıldığında implant üstü tam protezlerin ısırma kuvvetlerinin ve çiğneme kaslarının aktivitelerinde oluşturdukları değişikliklerin emg (electromiyografi) ile incelenmesi
Emg (electromyography) examination of biting forces and chewing muscles activity changes of implant supported overdentures when using different implants and retantive units
MERT UÇANKALE
Doktora
Türkçe
2006
Diş HekimliğiMarmara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF.DR. ENDER KAZAZOĞLU
PROF.DR. YASEMİN KULAK ÖZKAN
Y.DOÇ.DR. YAŞAR ÖZKAN
- Alt dişsiz çenede bar destekli implant üstü protezlerin stres dağılımlarının sonlu elemanlar stres analizi yöntemi ile değerlendirilmesi
Finite element analysis of implant-supported overdentures on edentulous mandible
ERKAN SANCAKLI
Doktora
Türkçe
2006
Diş HekimliğiHacettepe ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF.DR. AYŞEN NEKORA AZAK
- Alt çene tam ark implant destekli distal uzantılı sabit protezlerde implant sayısı distal uzantı uzunluğu ve kesit şeklinin implant çevre kemik dokusundaki gerilim dağılımına etkisinin fotoelastik stres analiz yöntemi il
Başlık çevirisi yok
ALP BENAN ÇEVİK
Doktora
Türkçe
1997
Diş HekimliğiMarmara ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF. DR. HASAN N. ALKUMRU
- Alt çene total dişsizlik vakalarında implant destekli protez uygulamalarında, implantların farklı lokalizasyonlarda yerleştirilmesinin ve farklı üst yapıların kullanılmasının kemikteki kuvvet dağılımına etkisinin sonlu elemanlar stres analizi yöntemi
A fem analysis study on the influence of alveolar arch form and implant positions on stress distribution around implants supporting fixed full-arch prostheses in edentulous mandible
MAHMUT ÖZKAN ÇANKAYA
Doktora
Türkçe
2005
Diş Hekimliğiİstanbul ÜniversitesiOral İmplantoloji Ana Bilim Dalı
PROF.DR. SERDAR YALÇIN
- Uzun ve kavisli sabit restorasyonlarda stres dağılımının incelenmesi
The evaluation of FEM analyzes in long span and curved fixed prostheses
KORAY CENAN
Doktora
Türkçe
2005
Diş Hekimliğiİstanbul ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
PROF.DR. MURAT AYDIN