Farklı implant-dayanak birleşim tasarımlarında vida mekaniğinin üç boyutlu sonlu eleman stres analizi ile incelenmesi
Evaluation of screw mechanics in different implant - abutment mating desing by three dimensional finite element stress analysis
- Tez No: 129873
- Danışmanlar: PROF. DR. SAİME ŞAHİN
- Tez Türü: Doktora
- Konular: Diş Hekimliği, Dentistry
- Anahtar Kelimeler: İmplant-dayanak birleşimi, vida mekaniği, non-linear sonlu eleman stres analizi, Implant-abutment mating design, screw mechanics, non-linear finite element stress analysis
- Yıl: 2003
- Dil: Türkçe
- Üniversite: Hacettepe Üniversitesi
- Enstitü: Sağlık Bilimleri Enstitüsü
- Ana Bilim Dalı: Protez Bilim Dalı
- Bilim Dalı: Belirtilmemiş.
- Sayfa Sayısı: Belirtilmemiş.
Özet
ÖZET Onat Ç., Farklı implant-dayanak birleşim tasarımlarında vida mekaniğinin üç boyutlu sonlu eleman stres analizi ile incelenmesi, Hacettepe Üniversitesi Sağlık Bilimleri Enstitüsü Protez (Diş) Programı Doktora Tezi, Ankara, 2003. Bu çalışmada, aynı yükleme koşulları altındaki farklı implant-dayanak birleşim tasarımlarına sahip iki implant sisteminin iki farklı çapında, implant komplekslerinde oluşan stres dağılımlarının mekaniksel özellikleri üç boyutlu sonlu eleman stres analizi ile incelendi. Bu amaç için, 4.1 mm ve 4.8 mm çaplarındaki iç konik implantlar ile 4 mm ve 5 mm çaplarındaki dış altıgen implantların, dayanakları ve kronlarıyla birlikte sonlu eleman modelleri oluşturuldu. Her bir implant kompleksine, yükleme koşulu 1: Dayanak vidasına uygulanan tork sonucu oluşan preload; yükleme koşulu 2a: Kron cusp tepesinden 150 N dikey; yükleme koşulu 2b: Kron cusp tepesinden, 150 N implant uzun eksenine oblik; yükleme koşulu 2c: Kron santral fossasından 150 N dikey olmak üzere dört farklı kuvvet uygulandı. Stres analizlerinin sonuçları, implant-dayanak birleşimi tasarımdaki ve implant çaplarındaki farklılıkların, implant komplekslerinde farklı mekaniksel davranışların sergilenmesine neden olduğunu gösterdi. Tüm yükleme koşullarında, iç konik implantlarda dış altıgen implantlara göre daha düşük stres değerleri elde edildi ve olası bir mekanik komplikasyon riskinin daha zayıf olduğu gözlendi. İç konik implantların her iki çapında stres büyüklükleri ve dağılımları benzer bulundu. Dış altıgen implantların 5 mm çapına kıyasla 4 mm çapında, streslerin dayanak vidasındaki yoğun ve yaygın dağılımı gözlendi. Tüm implant kompleksleri için mekaniksel açıdan en kritik sonuçların, implant uzun eksenine oblik yüklemelerle, en uygun sonuçların ise kronların santral fossasından dikey yüklemelerle elde edildiği görüldü. İmplant-dayanak birleşim tasarımı ve implant çapının dental implantların mekaniği üzerinde önemli etkileri bulunmaktadır.
Özet (Çeviri)
ABSTRACT Onat C, Evaluation of screw mechanics in different implant-abutment mating designs by three dimensional finite element stress analysis, Hacettepe University, Health Sciences Institute PhD Thesis in Prosthodontics, Ankara, 2003. In this study, mechanical stress distribution within the implant complex of two implant systems having different implant- abutment mating designs were evaluated by using three dimensional finite element stress analysis for two different implant diameters under identical loading conditions. In this regard, finite element models of 4.1 mm and 4.8 mm diameter internal cone, 4 mm and 5 mm diameter external hex implants with respective abutments and crowns were constructed. The following four load conditions were applied for each implant complex: Load condition 1 : Preload as a sequel of torque application on the abutment screw; Load condition 2a: 150 N vertical load application on the cusp; Load condition 2b: 150 N oblique load application on the cusp; Load condition 2c: 150 N load application on the central fossa of the crown. The non-linear contact analysis revealed that implant-abutment mating design and implant diameter had decisive effects on the mechanical characterisation of the implant complex. Under all loading conditions, stress magnitudes and hence, the possible risk of mechanical complications for internal cone implants were considerably lower than external hex implants. For both internal cone implants, similar stress magnitudes and distributions were obtained. In comparison with 5 mm diameter implant, high stress concentrations were observed for the 4 mm diameter external hex implant. Regardless of implant design, the most critical mechanical stresses were obtained under oblique loading, whereas favorable stress magnitudes and distributions, granting long-term implant-abutment joint integrity, were observed under vertical loading on the central fossa of the crown. Implant-abutment mating design and implant diameter have ruling effects on the mechanics of dental implants.
Benzer Tezler
- İki farklı implant tipinde implant-dayanak birleşim arayüzeyindeki mikroaralık mikrosızıntı miktarının dinamik yükleme öncesi ve sonrası kıyaslanması
The comparision of microgap and microleakage findings before and after dynamic loading at the implant-abutment interface at two different implant systems
AYŞEGÜL ŞİRANLI
- Üç farklı dayanak materyalinin dinamik yükleme sonucunda implant-dayanak birleşiminde meydana gelen değişiklikler ve dayanıklılık yönünden incelenmesi
Comparison of changes in the implant-abutment interface after dynamic loading and strength of three different abutment materials
BULEM YÜZÜGÜLLÜ
- Darbeli elektromanyetik alanlar ile osteojenik indüksiyon (teorik, deneysel ve klinik çalışma)
Başlık çevirisi yok
ARSLAN BORA
Tıpta Uzmanlık
Türkçe
1982
Ortopedi ve TravmatolojiEge ÜniversitesiOrtopedi ve Travmatoloji Ana Bilim Dalı
PROF. DR. MERİH EROĞLU
- Farklı implant sistemlerinde implant-destek parça birleşim yüzeyleri arası mikroorganizma sızıntısı ve çevre dokulara olası etkilerinin incelenmesi
Comparison of microbial leakage through various implant-abutment connection mechanisms and its possible effect on surrounding tissues
ALİ MÜFTÜ
- Farklı implant üstü restoratif materyallerin implant kemik ara yüzeyine dinamik kuvvetler altında ilettiği streslerin incelenmesi
Investigation of stresses transmitted by different superstructure restorative materials to implant bone interface under dynamic loads
TOLGA AKOVA
Doktora
Türkçe
2002
Diş HekimliğiÇukurova ÜniversitesiProtetik Diş Tedavisi Ana Bilim Dalı
DOÇ. DR. HAKAN UYSAL