Geri Dön

Van hava alanında oluşan gürültü kirliliğinin çalışanlar üzerindeki etkileri

An investigation on effects of noise pollution on the workers of Van Ferit Melen Airport

  1. Tez No: 118139
  2. Yazar: ZAFER AKAN
  3. Danışmanlar: PROF.DR. M. ALİ KÖRPINAR, PROF.DR. METİN TULGAR
  4. Tez Türü: Yüksek Lisans
  5. Konular: Biyofizik, Biophysics
  6. Anahtar Kelimeler: Gürültü, gürültü kirliliği, işitme kaybı, immunoglobulin, kan basıncı. 82, Noise, noise pollution, hearing loss, immunoglobulin, blood pressure. 83
  7. Yıl: 2002
  8. Dil: Türkçe
  9. Üniversite: Yüzüncü Yıl Üniversitesi
  10. Enstitü: Sağlık Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Biyofizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Akan Z. Gürültü Kirliliğinin Van Ferit Melen Haya Meydanı Çalışanları Üzerindeki Etkilerinin Araştırılması, Y.Y.Ü. Sağlık Bilimleri Enstitüsü, Yüksek Lisans Tezi, Van, 2002. Bu çalışma, Van Ferit Melen Hava Meydanı'nda çalışanlar üzerinde gürültü kirliliğinin etkisini araştırmak için planlanmıştır. Bu amaçla, kan örneklerinde immunoglobulin değerlerine bakılmış, kulak odyoları ve kan basınçları ölçülmüştür. Çalışmaya hava meydanında görevli 26 kişi (12 kişi apronda, 14 kişi terminalde) ve kontrol grubu olarak ise 1 1 kişi alınmıştır. Çalışanların etkilendikleri gürültü düzeyi uluslararası kabul edilen standart seviyenin (80 dB) üzerindedir (Apron ortalaması: 96±8,4 dB, Terminal ortalaması: 86±8,7 dB). IgG ve IgM değerleri istastistiksel bakımdan anlamsız günlük dalgalanmalar göstermesine karşın, IgG değeri terminal ve apron çalışanlarında sabahtan akşama kadar artan bir değer izlemiştir. Grupların sabah ölçülen IgA değerleri arasında istatistiksel bakımdan anlamsız (p>0,05) bulunurken, akşam kaydedilen değerlerde kontrol grubuna göre önemli farklar gözlenmiştir (p<0,05). Sabah alınan IgG değerleri kontrol grubuna göre daha fazla bulunmuştur. Sistolik kan basıncı değerleri terminal ve apron çalışanlarında kontrol grubuna göre artmıştır (p<0,05). Terminal çalışanlarında öğle ve akşam farkları önemlidir (p0,004; p=0,015). Apron çalışanlarında ise sadece öğlen kaydedilen değerler önemli şekilde farklıdır (p=0,049). Terminal ve apron çalışanlarında sistolik kan basıncı sabahtan öğleye artan ve akşam yükselen günlük dalgalanmalar göstermiştir. Sabah- öğlen ve öğlen-akşam arasındaki değişiklikler terminal çalışanlarında önemli bulunmuştur (p=0,035; p=0,043), fakat sabah-akşam değerleri arasında önemli bir fark yoktur. Diyastolik kan basıncı seviyeleri sadece terminal çalışanlarında artmıştır (p<0,005). Apron ve terminal çalışanlarının sabah-öğle arasında kaydedilen nabız değerleri önemli şekilde farklıdır (p<0,05). Apron çalışanlarının öğle-akşam değerleri arasında da önemli fark vardır (p=0,004). Fakat sayımlar sabahtan öğleye artarken, akşam düşme eğilimi göstermiştir. İstatistiksel olarak anlamlı tek fark apron ve terminal çalışanlarının sabah ölçülen değerleri arasında oluşmuştur. Apron ve terminal çalışanlarında 250, 500, 1000, 2000, 4000 ve 6000 Hz'lik frekansların hepsinde kontrol grubuna göre mesai içerisinde artan ve mesai sonunda azalan işitme kayıpları (TTS) oluşmuştur (p<0,05). İşitme kaybı terminal çalışanlarında daha fazladır. Bunun sebebi terminal çalışanlarının gürültü altında çalışma sürelerinin apron çalışanlarından fazla olmasına bağlanmıştır.

Özet (Çeviri)

SUMMARY Akan Z. An investigation on the effects of noise pollution on the workers of Van Ferit Melen Airport University of Yüzüncü Yd, Institute of Health Sciences, M.S Thesis, Van, 2002. This study was planned to investigate the effects of noise pollution on the workers of Van Ferit Melen Airport. For this purpose, immunoglobulin (Ig) levels in blood samples, audiometric parameters and blood pressures were measured. Twenty six workers of the airport (12 on the apron, 14 on the terminal) and 1 1 controls participated in the study. The level of the noise effecting the workers was higher than the international acceptable standards (80 dB) (mean values; Apron: 96+8,4 dB; Terminal: 86+8,7 dB). Levels of IgA increased from morning to evening in both terminal and apron workers. Levels of IgG and M showed statistically no significant daily alterations. While there was no statistically significant difference between morning IgA levels of these two group of workers and the control group (p>0,05), significant differences were observed for evening levels of IgA of terminal workers (p=0,004) and apron workers (p=0,025) in comparison with control cases. Morning levels of IgG was found to be higher than those of control cases (p=0,001). Systolic blood pressure levels were increased in both terminal and apron workers in comparison with control cases (p<0,05). In terminal workers, differences for midday and evening were significant (p=0,004; p=0,015). In apron workers, difference for midday was significant (p=0,049). Systolic blood pressure levels showed daily alterations as increasing from morning to midday and decreasing to initial level in the evening in both of the terminal and apron workers. Daily alterations in terminal workers were found to be significant between morning and midday (p=0,035) and midday and evening (0,043); but mere was no significant difference between morning and evening values. Diastolic blood pressure levels were increased only in terminal workers (p<0,005). The pulse counts per minute increased from morning to midday and decreased to initial level in the evening. Pulses/minute were significantly different between morning and midday in apron and terminal workers (p<0,005). When the recordings of apron workers during midday and evening were compared, there was also significant difference (p=0,004). There was also significant difference between morning and evening pulse counts of terminal workers (p=045). In comparison with control cases, the only statistically significant difference was recorded between the values of apron workers and control cases in the morning (p=0,027). Significant hearing losses which gradually increased during the shift and decreased by the end were found in both apron and terminal workers compared with the control group at all frequencies (250 Hz, 500 Hz, 1000 Hz, 2000 Hz, 4000 Hz and 6000 Hz) tested (p<0,005). Hearing loss of terminal workers was more than that of the other group. This might result from the working period under noise that was longer for terminal workers.

Benzer Tezler

  1. Yeni Cami'nin akustik açıdan performans değerlendirmesi

    Evaluation of the acoustical performance of the New Mosque

    EVREN YILDIRIM

    Yüksek Lisans

    Türkçe

    Türkçe

    2003

    Mimarlıkİstanbul Teknik Üniversitesi

    Mimarlık Ana Bilim Dalı

    PROF. DR. SEVTAP YILMAZ DEMİRKALE

  2. Ejderhanın motif olarak gelişimi ve Osmanlı sanatında kullanımı (1453-1600)

    Başlık çevirisi yok

    CANDAN ÜLKÜ

    Doktora

    Türkçe

    Türkçe

    1995

    Arkeolojiİstanbul Üniversitesi

    DOÇ.DR. TARCAN YILMAZ

  3. İki değerli demir sülfattan 1-Fe2O3 sentezi vekarakterizasyonu

    Başlık çevirisi yok

    HAKAN SESİGÜR

    Yüksek Lisans

    Türkçe

    Türkçe

    1996

    Metalurji Mühendisliğiİstanbul Teknik Üniversitesi

    DOÇ.DR. ERCAN AÇMA

  4. Van'da yetiştirilen bazı elma çeşitlerinin dış hava ile soğutulan adi depoda muhafaza olanakları üzerine bir araştırma

    Başlık çevirisi yok

    ÜMİT SÜLEYMAN ASLAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1999

    ZiraatYüzüncü Yıl Üniversitesi

    Bahçe Bitkileri Ana Bilim Dalı

    YRD. DOÇ. DR. M. ALİ KOYUNCU