Geri Dön

“Yeni tip potansiyometrik üre biyosensörlerin hazırlanması ve biyolojik numunelere uygulanması”

“Preparation of new type potentiometrik urea biosensors and application to biological samples”

  1. Tez No: 105757
  2. Yazar: OSMAN ÇUBUK
  3. Danışmanlar: YRD. DOÇ. DR. NİHAT TINKILIÇ
  4. Tez Türü: Yüksek Lisans
  5. Konular: Kimya, Chemistry
  6. Anahtar Kelimeler: Twin-Membran Biyosensörler, Üre Biyosensörler, Glukoz Biyosensörler, Potansiyometrik Biyosensörler, Tamamıyla Katı-Hal Kontaktlar, PVC-NH2 Membran Elektrotlar, Biyosensörler, Enzim sensörleri, Twin-Membrane Biosensors, Urea Biosensors, Glucose Biosensors, Potentiometric Biosensors, All Solid-State Contacts, PVC-NH2 Membrane Electrodes, Biosensors, Enzyme sensors
  7. Yıl: 2001
  8. Dil: Türkçe
  9. Üniversite: Ondokuz Mayıs Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Kimya Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

YENİ TIP POTANSIYOMETRIK ÜRE BIYOSENSORLERIN HAZIRLANMASI VE BİYOLOJİK NUMUNELERE UYGULANMASI ÖZET Glukoz oksidaz ve üreazın immobilizasyonuyla, tamamıyla katı-hal kontakt PVC- NH2 membran iyon seçici elektrotlarda temel teşkil eden minyatürize edilebilir glukoz ve üre biyosensörler hazırlandı. Enzimler tamamıyla katı-hal kontakt amonyum veya pH duyar elektrot membranları üzerine kimyasal olarak tutturuldu. Geliştirilen biyosensörlerin, normal PVC membranlarla aynı potansiyometrik özelliklere sahip olduğu görüldü. Glukoz ve üre biyosensörlerin en önemli özellikleri, yüksek seçicilik, uzun kullanım ömrü, düşük maliyette yapılabilmeleri, minyatürize edilebilmeleri ve kısa cevap zamanına sahip olmalarıdır. Glukoz ve üre biyosensörlerin karakteristik özellikleri farklı pH ve değişik konsantrasyonlardan tampon çözeltileri kullanılarak test edildi. İmmobilizasyon şartlarının, elektrotların kullanım ömrü ve dinamik cevap özelliklerine etkisi araştırıldı. Optimum şartlar altında, üre biyosensör 5.10“ -5.10 M üre çözeltisine lineer bir cevap sergilerken, glukoz elektrot 5.10”2 - 1. 10“4 M glukoz çözeltisine lineer cevap sergiledi. Biyosensörlerin duyarlılıklarını ve yaşam sürelerini arttırmak için, yeni bir yaklaşımla tamamıyla katı-hal kontakt PVC ve PVC-NH2' de temel teşkil eden ”twin- membran" üre biyosensörler geliştirildi. Geliştirilen twin-membran üre biyosensörlerin potansiyometrik davranışları incelendi. Twin-membran üre biyosensörlerin potansiyometrik performansları, bilinen üre biyosensörlerle aym özellikte, cevap süreleri daha kısa, kullanım ömürleri daha uzun ve seçiciliklerinin yüksek olduğu görüldü. Geliştirilen twin- membran üre biyosensörleri ile kan numunelerinde üre tayini yapıldı.

Özet (Çeviri)

11 PREPARATION OF NEW TYPE POTANTIOMETRIC UREA BIOSENSORS AND APPLICATION TO BIOLOGICAL SAMPLES ABSTRACT Miniaturised glucose and urea sensors prepared by immobilisation of glucose oxidase or urease onto all solid-state contact PVC-NH2 membrane ion selective electrodes are described. Enzymes were chemically immobilised directly onto all solid-state contact ammonium and pH sensitive electrode membranes. The resulting biosensing membranes function equivalents to normal PVC membranes in terms of potentiometric response properties. The most important features of the obtained glucose and urea sensors were high sensitivity, long life-time, easily built at a low cost, micro-construction and short response time. The characteristics of the glucose and urea sensors were examined in several buffer solutions at different concentrations and pH values. The influence of immobilisation conditions on the dynamic response properties and life-time of the electrodes was studied. Under optimal conditions, the urea electrode showed a linear response relationship between 5.10“2 and 5.10”4 M urea, while the glucose electrode showed a linear response relationship between 5. 1 0“2 and 1. 1 0”4 M glucose. To increase the selectivity and life times of biosensors, a novel approach has been developed to construct all solid-state contact PVC and PVC-NH2 twin-membrane urea biosensors. The construction and the use of twin-membrane biosensors described in brief. Twin-membrane urea biosensors exhibited short response times and extended life-time without any loss of its potentiometric performance. Twin-membrane urea biosensors also resulted higher selectivity urea when compared with conventional urea biosensors.

Benzer Tezler

  1. Yeni tip sobaların ısıl verim ve emisyon davranışlarının deneysel incelenmesi

    Experimental investigation of emission behaviour and thermal efficiency of new type stoves

    MERAL TOPÇUOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1995

    Makine MühendisliğiGazi Üniversitesi

    PROF.DR. ALİ DURMAZ

  2. Yeni tip dallanmış vic-dioksim ve geçiş metal komplekslerinin sentezi

    Başlık çevirisi yok

    EMEL MUSLUOĞLU

    Doktora

    Türkçe

    Türkçe

    1996

    Kimyaİstanbul Teknik Üniversitesi

    PROF.DR. ÖZER BEKAROĞLU

  3. Yeni tip türbülatörlerin ısı transferine ve basınç kayıplarına olan etkilerinin araştırılması

    Effect of a new type turbulator in heat transfer and pressure loss

    BÜLENT ÇULCU

    Yüksek Lisans

    Türkçe

    Türkçe

    1998

    Makine MühendisliğiFırat Üniversitesi

    Makine Eğitimi Ana Bilim Dalı

    YRD. DOÇ. DR. AYDIN DURMUŞ