Geri Dön

Süt endüstrisi atıksularının membran prosesler kullanılarak arıtılabilirliği ve geri kazanımı

Reuse and treatability of dairy industry wastewater using membrane processes

  1. Tez No: 104155
  2. Yazar: ALPER ATEŞ
  3. Danışmanlar: DOÇ. DR. MUSTAFA TURAN
  4. Tez Türü: Yüksek Lisans
  5. Konular: Çevre Mühendisliği, Environmental Engineering
  6. Anahtar Kelimeler: Süt endüstrisi atıksulan, nNanofîltrasyon, ters osmoz, süzüntü akısı, özgül enerji tüketimi, KOİ giderimi XI, Atık su arıtma, Endüstriyel atık su, Membran süreci, Membranlar, Süt endüstrisi, Dairy industry wastewater, nanofiltration, reverse osmosis, permeate flux, specific energy consumption, COD removal. xii, Waste water treatment, Industrial waste water, Membrane process, Membranes, Dairy industry
  7. Yıl: 2001
  8. Dil: Türkçe
  9. Üniversite: İstanbul Teknik Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Çevre Mühendisliği Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

SÜT ENDÜSTRİSİ ATIKSULARININ MEMBRAN PROSESLER KULLANARAK ARITILABİLİRLİĞİ VE GERİ KAZANIMI ÖZET Nanofiltrasyon (NF) ve ters osmoz (RO) membranlan süt endüstrisi atıksulannın arıtılması ve geri kazanımı için kullanılmıştır. Pilot tesis çalışması, 2m2 yüzey alanı olan film kompozit tip NF (TCF-S) ve RO (TCF-HR) membranlan ile yürütülmüş, sistem akışölçer, basınç sensörleri, kartuş filtre ve pompalar ile donatılmıştır. Tek membran için geri kazanma, RO ve NF için sırasıyla %16 ve 30 olmaktadır. Süzüntü akısı operasyon boyunca zamana bağlı olarak düşüş göstermiş, basınçtaki artışla birlikte süzüntü akısı da artmıştır. Aynı basınç değerinde, RO daki süzüntü akısı NF dekinden daha düşüktür. Her iki memoranda 60 saatlik bir çalışmadan sora süzüntü akısı yaklaşık olarak %50 azalmıştır. Özgül enerji tüketimi, zamana bağlı olarak artmış, basınçtaki artışa bağlı olarak da azalmıştır. Birim m3 süzüntü suyu başına ortalama enerji tüketimi NF ve RO membranlan için sırasıyla 6 ve 10 kWh/m3 mertebesindedir. NF ve RO membranlannm işletme masrafları sırasryla U.S.$0.45/m3 and 0.75 U.S.$/m3 olarak belirlenmiştir. Toplam sertlik, kimyasal- biyolojik arıtma tesisindeki arıtma prosesi dolayısıyla çıkışta artmış, bu da NF membranı kullanımını gerektirmiştir. Toplam sertlik giderimi, NF ve RO için sırasıyla %74-100 ve %94-100 olmaktadır. İletkenlikteki tutma NF için %94-98, RO için ise %92-95 arasmda; NF deki KOİ giderimi %95-98 ve RO daki KOİ giderimi %92-95 arasında yüksek mertebededir. Membran proseslerinin süt endüstrisinde gerek arıtma tesisi öncesi ve gerekse çıkış suyunda uygulanabilirliği gösterilmiş ve üretilen suyun tekrar laıllanılabilme potansiyelinin bulunduğu ortaya koymuştur.

Özet (Çeviri)

REUSE AND TREATABILITY OF DIARY INDUSTRY WASTEWATER USING MEMBRANE PROCESSES SUMMARY Nanofiltration (NF) and Reverse osmosis (RO) were evaluated for treatment of the effluent of chemical-biological treatment plant and the orginal effluent of dairy indutry respectively. It was used a thin film composite type of spiral wound membrane (2 m2 area) with The NF (TFC-S) and the RO (TFC-HR). The runs were conducted at approximately 16 and 30% water recovery of a single membrane at different pressures and flowrates for the RO and NF respectively. Permeate flux declined rapidly at beginning of the run and then appeared remain approximately constant after 50 h of operation at different pressures. Specific energy consumption increased as a function of time and decreased with increasing pressure for each membrane. The average of specific energy consumption was obtained at 6 and 10 kWh/m3 for the NF and RO units respectively. Therefore, the NF and RO operational cots were estimated at U.S.$ 0.45/m3 and U.S.$ 0.757m3 respectively. The operational costs of treatment of the dairy industry effluent with the chemical- biological proses followed by NF membrane and with only the RO membrane were nearly equal. In the effluent containing high concentration, total hardness of the NF feed and RO feed reduced from 1425 to 280 mgCaCOs/l (80% removal) and from 480 to 15 mgCaC03/l (97% removal) respectively. The conductivities of the NF feed, permeate were obtained approximately to the RO feed, permeate. COD of the NF feed and RO feed also reduced from 470 to 9 mg/l(98% removal) and froml0500 to 80 mg/l(99% removal) respectively. Therefore, it was found that the product water has reuse potential for diary industry,

Benzer Tezler

  1. Membran arıtma sistemiyle endüstriyel atıksuların arıtılması

    Industrial wastewater treatment by membrane treatment system

    ÖZLEM SELÇUK

    Yüksek Lisans

    Türkçe

    Türkçe

    2000

    Çevre MühendisliğiSüleyman Demirel Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    PROF. DR. NAZMİ TOPÇU

  2. Süt ve süt ürünleri endüstrisi atıksularının arıtılabilirliği üzerine bir çalışma

    A Study on treatibility of dairy wastewater

    ERDOĞAN ŞENOL

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Çevre MühendisliğiSakarya Üniversitesi

    Çevre Mühendisliği Ana Bilim Dalı

    YRD. DOÇ. DR. BÜLENT ŞENGÖRÜR

  3. Süt ve süt ürünleri endüstrisi atıksularının kimyasal arıtılabilirliği

    Chemical treatabality of dairy wastewater

    ALPASLAN EKDAL

    Yüksek Lisans

    Türkçe

    Türkçe

    2000

    Çevre Mühendisliğiİstanbul Teknik Üniversitesi

    DOÇ.DR. AYŞEGÜL TANIK

  4. Bursa bölgesi gıda sanayii atık sularının çevre kirliliğine etkileri

    Başlık çevirisi yok

    EMEL ZEYTİNOĞLU

    Yüksek Lisans

    Türkçe

    Türkçe

    1993

    Çevre MühendisliğiUludağ Üniversitesi

    Besin Hijyeni ve Teknolojisi Ana Bilim Dalı

    PROF. DR. AŞKIN BERKER

  5. İzmit Körfez suyunun kirlilik parametreleri üzerinde fabrika atık sularının rolü

    Başlık çevirisi yok

    RABİA ÇOBAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1997

    Çevre MühendisliğiUludağ Üniversitesi

    Besin Hijyeni ve Teknolojisi Ana Bilim Dalı

    DOÇ.DR. ECE SOYUTEMİZ