Geri Dön

Yüksek sıcaklıklarda metallerin özdirencini ölçen bir sistemin geliştirilmesi

Başlık çevirisi mevcut değil.

  1. Tez No: 10278
  2. Yazar: MEHMET GÖZ
  3. Danışmanlar: PROF. DR. ASLAN EROĞLU
  4. Tez Türü: Yüksek Lisans
  5. Konular: Fizik ve Fizik Mühendisliği, Physics and Physics Engineering
  6. Anahtar Kelimeler: Metaller, Yüksek sıcaklık, Öz direnç, Metals, High temperature, Resistivity
  7. Yıl: 1990
  8. Dil: Türkçe
  9. Üniversite: Ege Üniversitesi
  10. Enstitü: Fen Bilimleri Enstitüsü
  11. Ana Bilim Dalı: Fizik Ana Bilim Dalı
  12. Bilim Dalı: Belirtilmemiş.
  13. Sayfa Sayısı: Belirtilmemiş.

Özet

ÖZET Metallerin özdirenci yüksek sıcaklıklarda T ile, 5 alçak sıcaklıklarda T ile orantılıdır. Mott teorisine göre, yüksek sıcaklıklarda geçit metallerin özdirenci lineeri ikten sapar. Ferromanyetik metallerin faz değişimi Curie sıcaklığı ile belirlenir. Bu çalışmada, metal ve alaşımların özdirencini ölçen bir sistem geliştirilmiştir, özdirenç 10-3 torr basınçta oda sıcaklığı ile 1300 K arasında ölçülmüştür. Sistem; ölçüm odası, fırın ve sıcaklığı ölçen kontrol eden dijital bir sistemden oluşmaktadır. ölçüm odası 300 cm çelik tüpten yapılmış olup ve basıncı 10 torra kadar düşürülebilir. özdirenci ölçülecek örnek ölçüm odasının merkezine yerleştirildi. 1350 W lık bir 3 güç ile 1300 K sıcaklığa çıkabilen fırın llxl4x22 cm3 çalışma hacimine sahiptir. Kantal tel, seramik fibre ve mikanit sırasıyla ısıtma elemanı, ısı yalıtım malzemesi ve refrakter olarak kullanılmıştır. Sıcaklığı ölçme ve kontrol sistemi TSC 7107 ve LM 358 entegreleri kullanılarak yapıldı. Sıcaklığı ölçmek için, Ni - NiCr termoçifti sensör olarak kullanılmıştır. Yüksek sıcaklıklarda sıcaklık stabilitesi 4 derecedir. Elektriksel özdirenç four probe metodu kullanılarak belirlendi. Fe, Ni ve A1<A1203> alaşımının özdirenci sıcaklığın fonksiyonu olarak ölçüldü. Yükseksıcaklıklarda termal genleşmeden dolayı özdirenç düzeltilmesi yapıldı. Fe ve Ni ' in özdirenç eğrisi lineer değildir. Ni ve Fe ' in Curie sıcaklığı sırasıyla 631^3 K ve 1043^5 K olarak belirlendi. ölçümler litaratürle uyum içindedir. Al(AlgÜ3) alaşımının özdirenci artan sıcaklık ile lineer arttığı gözlendi. özdirenç eğrisinden, eğrinin eğimi 0.00847 + 0.00007 pilcm/K olarak bulunmuştur. 39

Özet (Çeviri)

SUMMARY Electrical resistivity of metals is proportional with g T at high temperature and with T at low temperatures. According to the Mott theory, the resistivity of transtion metals at high temperature deviates from linearity. The magnetic phase change of ferromagnetic metals is determined by Curie temperature. In this study, a system to measure the resistivity of metals and alloys at high temperature is developed. The resistivity has been measured between the room -3 temperature and 1300 K at a pressure of 10 torr. The system contains a measuring chamber, oven and a digital system which controls and measures the temperature. The 3 measuring chamber is made of a steel tube of 300 cm and -3 the pressure in this can be decreased down to 10 torr. the samples were placed in the centre of it. The oven, capable of achieving a temperature of 1300 K with a power of 1350 W, has a working volume which is roughly 11x14x22 3 cm. Kantal wire, ceramics fibre and micanite were used as heating element, thermal insulation and refractory respectively. The temperature measuring and controlling system was made by using TSC 7107 and LM 358 integrated circuits. To measure the temperature, Ni- NiCr was used as a thermocouple sensor. Temperature stability was about ^:4 degrees at high temperatures. 40The electrical resistivity was determined by using four probe method. The resistivities of Ni, Fe and AMAI2O3) alloy were measured as a function of temperature. The resistivity was corrected to the thermal expansion at high temperatures. The resistivity curves of Ni and Fe are not linear. Curie temperatures of Ni and Fe were determined as 631 ?3 K ve 1043^5 K respectively. The measurements were a good in agreement with the literature. It is observed that the resistivity of Al(Alg03> alloy increases linearly with inceasing temperature. From the resistivity curve, it was found that the slope of the curve was 0. 008^7^ 0.00007 nQcm/K. 41

Benzer Tezler

  1. The Construction and characterization of high accuracy platinum based thermocouples

    Yüksek doğruluklu platin ısılçiftlerin yapım ve kalibrasyonları

    MURAT KALEMCİ

    Yüksek Lisans

    İngilizce

    İngilizce

    1999

    Fizik ve Fizik MühendisliğiOrta Doğu Teknik Üniversitesi

    Fizik Ana Bilim Dalı

    DOÇ. DR. DEMET GÜLEN

    DOÇ. DR. SEVİLAY UĞUR

  2. Uranyum (VI), toryum (IV), kalay (II) ve kalay (IV) ün schiff bazı komplekslerinin hazırlanması ve yapılarının spektrofotometrik yöntemlerle açıklanması

    Preparation of schiff base complexes of uranium (VI), thorium (IV), tın (II) and tın (IV) and determination of their structures by spectrometric methods

    YAKUP BARAN

    Yüksek Lisans

    Türkçe

    Türkçe

    1985

    KimyaGazi Üniversitesi

    DOÇ. DR. BİRGÜL ERK

  3. Thermal and mechanical behaviour of plasma-sprayed oxide ceramic coatings on steels

    Başlık çevirisi yok

    MURAT VURAL

    Yüksek Lisans

    İngilizce

    İngilizce

    1991

    Uçak Mühendisliğiİstanbul Teknik Üniversitesi

    PROF.DR. A. HİKMET ÜÇIŞIK

  4. Şeker üretim artığı karbonatlama keki kullanılarak atık sulardan Krom(III) ve kadmiyum giderilmesi

    Removal of chromium (III) and cadmium from wastewater by using carbonatation cake discarded in sugar production

    OĞUZALP GÜLER

    Yüksek Lisans

    Türkçe

    Türkçe

    1999

    Kimya MühendisliğiFırat Üniversitesi

    Kimya Mühendisliği Ana Bilim Dalı

    PROF. DR. FİKRET TÜMEN